1,275 research outputs found

    A 43-Gbps Lithium Niobate Modulator Driver Module

    Get PDF
    This paper describes the realization of a 43-Gbps Lithium Niobate modulator driver module. The NRZ driver module utilizes four stages of GaAs p-HEMT MMIC amplifiers integrated with an output level detector and feedback loop to provide thermal stability and external control of the output swing. The bias and loop control circuitry are contained in the housing on a PC board external to the sealed MIC section. The integrated module (50.8 x 73.4 x 9.5 mm 3) provides 6.0 Vp-p controllable single-ended output voltage while dissipating only 4 watt

    Detecting Planets Around Very Low Mass Stars with the Radial Velocity Method

    Full text link
    The detection of planets around very low-mass stars with the radial velocity method is hampered by the fact that these stars are very faint at optical wavelengths where the most high-precision spectrometers operate. We investigate the precision that can be achieved in radial velocity measurements of low mass stars in the near infrared (nIR) Y-, J-, and H-bands, and we compare it to the precision achievable in the optical. For early-M stars, radial velocity measurements in the nIR offer no or only marginal advantage in comparison to optical measurements. Although they emit more flux in the nIR, the richness of spectral features in the optical outweighs the flux difference. We find that nIR measurement can be as precise than optical measurements in stars of spectral type ~M4, and from there the nIR gains in precision towards cooler objects. We studied potential calibration strategies in the nIR finding that a stable spectrograph with a ThAr calibration can offer enough wavelength stability for m/s precision. Furthermore, we simulate the wavelength-dependent influence of activity (cool spots) on radial velocity measurements from optical to nIR wavelengths. Our spot simulations reveal that the radial velocity jitter does not decrease as dramatically towards longer wavelengths as often thought. The jitter strongly depends on the details of the spots, i.e., on spot temperature and the spectral appearance of the spot. Forthcoming nIR spectrographs will allow the search for planets with a particular advantage in mid- and late-M stars. Activity will remain an issue, but simultaneous observations at optical and nIR wavelengths can provide strong constraints on spot properties in active stars.Comment: accepted by ApJ, v2 accepted revision with new precision calculations, abstract abride

    Hyperspectral Fluorescence and Reflectance Imaging Instrument

    Get PDF
    The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis

    Disinfection of Spacecraft Potable Water Systems by Photocatalytic Oxidation Using UV-A Light Emitting Diodes

    Get PDF
    Ultraviolet (UV) light has long been used in terrestrial water treatment systems for photodisinfection and the removal of organic compounds by several processes including photoadsorption, photolysis, and photocatalytic oxidation/reduction. Despite its effectiveness for water treatment, UV has not been explored for spacecraft applications because of concerns about the safety and reliability of mercury-containing UV lamps. However, recent advances in ultraviolet light emitting diodes (UV LEDs) have enabled the utilization of nanomaterials that possess the appropriate optical properties for the manufacture of LEDs capable of producing monochromatic light at germicidal wavelengths. This report describes the testing of a commercial-off-the-shelf, high power Nichia UV-A LED (250mW A365nnJ for the excitation of titanium dioxide as a point-of-use (POD) disinfection device in a potable water system. The combination of an immobilized, high surface area photocatalyst with a UV-A LED is promising for potable water system disinfection since toxic chemicals and resupply requirements are reduced. No additional consumables like chemical biocides, absorption columns, or filters are required to disinfect and/or remove potentially toxic disinfectants from the potable water prior to use. Experiments were conducted in a static test stand consisting of a polypropylene microtiter plate containing 3mm glass balls coated with titanium dioxide. Wells filled with water were exposed to ultraviolet light from an actively-cooled UV-A LED positioned above each well and inoculated with six individual challenge microorganisms recovered from the International Space Station (ISS): Burkholderia cepacia, Cupriavidus metallidurans, Methylobacterium fujisawaense, Pseudomonas aeruginosa, Sphingomonas paucimobilis and Wautersia basilensis. Exposure to the Nichia UV-A LED with photocatalytic oxidation resulted in a complete (>7-log) reduction of each challenge bacteria population in <180 minutes of contact time. With continued advances in the design and manufacture of UV-A LEDs and semi-conducting photocatalysts, LED activated photochemical process technology promises to extend its application to spacecraft environmental systems

    The Impact of Endothall on the Aquatic Plant Community of Kress Lake, Washington

    Get PDF
    CA dense mat-forming population of Eurasian watermilfoil ( Myriophyllum spicatum L . ) was interfering with fishing and recreation in a small western Washington lake. A low concentration (1.5 mg/L active ingredient) of the herbicide endothall formulated as Aquathol® K was used in 2000 to attempt to selectively control the Eurasian watermilfoil. Aquatic plant biomass and frequency data were collected before treatment, ten weeks after treatment and during the growing season for 3 additional years. Macrophyte data were analyzed to assess the herbicide’s impacts on Eurasian watermilfoil as well as the rest of the aquatic plant community. Results showed a significant decrease in Eurasian watermilfoil biomass and frequency 10 weeks after treatment. The Eurasian watermilfoil continued to be present, but at a significantly reduced level through the remainder of the study (3 years after treatment). Of the native plant species, large-leaf pondweed ( Potamogeton amplifolius Tucker . ) frequency and biomass was significantly reduced after treatment. Common elodea ( Elodea canadensis Rich.), muskgrass ( Chara sp. Vallaint.) and bladderwort ( Utricularia sp. L.) all increased significantly after treatment. (PDF has 6 pages.

    Is it possible to detect planets around young active G and K dwarfs?

    Get PDF
    Theoretical predictions suggest that the distribution of planets in very young stars could be very different to that typically observed in Gyr old systems that are the current focus of radial velocity surveys. However, the detection of planets around young stars is hampered by the increased stellar activity associated with young stars, the signatures of which can bias the detection of planets. In this paper, we place realistic limitations on the possibilities for detecting planets around young active G and K dwarfs. The models of stellar activity based on tomographic imaging of the G dwarf HD 141943 and the K1 dwarf AB Dor also include contributions from plage and many small random starspots. Our results show that the increased stellar activity levels present on young solar-type stars strongly impacts the detection of Earth-mass and Jupiter-mass planets and that the degree of activity jitter is directly correlated with stellar v sin i. We also show that for G and K dwarfs, the distribution of activity in individual stars is more important than the differences in induced radial velocities as a function of spectral type. We conclude that Jupiter-mass planets can be detected close-in around fast-rotating young active stars, Neptune-mass planets around moderate rotators and that Super-Earths are only detectable around very slowly rotating stars. The effects of an increase in stellar activity jitter by observing younger stars can be compensated for by extending the observational base-line to at least 100 epochs.Peer reviewe

    Genome scan of Diabrotica virgifera virgifera for genetic variation associated with crop rotation tolerance

    Get PDF
    Crop rotation has been a valuable technique for control of Diabrotica virgifera virgifera for almost a century. However, during the last two decades, crop rotation has ceased to be effective in an expanding area of the US corn belt. This failure appears to be due to a change in the insect's oviposition behaviour, which, in all probability, has an underlying genetic basis. A preliminary genome scan using 253 amplified fragment-length polymorphism (AFLP) markers sought to identify genetic variation associated with the circumvention of crop rotation. Samples of D. v. virgifera from east-central Illinois, where crop rotation is ineffective, were compared with samples from Iowa at locations that the behavioural variant has yet to reach. A single AFLP marker showed signs of having been influenced by selection for the circumvention of crop rotation. However, this marker was not diagnostic. The lack of markers strongly associated with the trait may be due to an insufficient density of marker coverage throughout the genome. A weak but significant general heterogeneity was observed between the Illinois and Iowa samples at microsatellite loci and AFLP markers. This has not been detected in previous population genetic studies of D. v. virgifera and may indicate a reduction in gene flow between variant and wild-type beetles

    Spot sizes on Sun-like stars

    No full text
    The total area coverage by starspots is of interest for a variety of reasons, but direct techniques only provide estimates of this important quantity. Sunspot areas exhibit a lognormal size distribution irrespective of the phase of the activity cycle, implying that most sunspots are small. Here we explore the consequences if starspot areas were similarly distributed. The solar data allow for an increase in the fraction of larger sunspots with increasing activity. Taking this difference between the size distribution at sunspot maximum and minimum, we extrapolate to higher activity levels, assuming different dependencies of the parameters of the lognormal distribution on total spot coverage. We find that even for very heavily spotted (hypothetical) stars a large fraction of the spots are smaller than the current resolution limit of Doppler images and might hence be missed on traditional Doppler maps.Comment: 10 pages with 10 figures, accepted for publication in MNRA

    Surface Geometric and Electronic Structure of BaFe2As2(001)

    Full text link
    BaFe2As2 exhibits properties characteristic of the parent compounds of the newly discovered iron (Fe)-based high-TC superconductors. By combining the real space imaging of scanning tunneling microscopy/spectroscopy (STM/S) with momentum space quantitative Low Energy Electron Diffraction (LEED) we have identified the surface plane of cleaved BaFe2As2 crystals as the As terminated Fe-As layer - the plane where superconductivity occurs. LEED and STM/S data on the BaFe2As2(001) surface indicate an ordered arsenic (As) - terminated metallic surface without reconstruction or lattice distortion. It is surprising that the STM images the different Fe-As orbitals associated with the orthorhombic structure, not the As atoms in the surface plane.Comment: 12 pages, 4 figure
    corecore