99 research outputs found
二维扫描法测量连续型激光器的远场分布
本文提出用二维扫描法测量连续型激光器远场分布.其原理是:被测激光束先经衰减器将功率密度衰减至10~(-2)~10~(-4)瓦/(厘米)~2然后经聚焦镜及平镜反射,聚焦于扫描筒内壁之上,扫描筒壁上有一系列螺旋状分布小孔,各相邻两孔间夹角及轴向距离都相同,首末两孔间轴向距离及相邻两孔圆心间弧线在圆筒横截面上的投影长度均应稍大于欲测光斑直径,当圆筒用电动机带动旋转时,各小孔依次扫过光斑.透过小孔的光线用聚焦镜会聚于探测器上,探测器输出信号经放大器放大后由示波器记录,经整理后可得到“三维”远场
Service life and performance requirement in seismic design and durability design of coastal high-rise buildings
从沿海高层建筑的抗震与耐久性设计出发,探讨了抗震设计与耐久性设计的设计使用年限、性能要求。设计使用年限的增加意味着地震重现期要延长,对发震断裂带上的建筑地震设防烈度会增大,远离发震断裂带的建筑地震出现的次数增加。耐久性和抗震性危害留的余地不同,耐久性小,抗震性大。但如果耐久性下降会引起抗震性降低。所以保证耐久性是保证抗震性的前提,重视突发性抗震性损坏的同时,不应该忽略长期耐久性损坏的预防。耐久性不足,既增加了结构使用过程中的修理与加固费用,也会降低结构的抗震能力。抗震的性能要求主要体现在保证结构的足够强度、刚度、整体性和稳定性,而耐久性设计要对混凝土材料、结构构造、施工要求等提出要求。Considering the seismic and durability design of coastal high-rise buildings,the service life and performance requirement in seismic design and durability design are discussed.The prolong of service life presumes the extending of earthquake return period,the augmentation of earthquake fortification intensity in fracturing segment and the increment of earthquake arisen apart from fracturing segment.The leaving space for durability and seismic danger is different,durability design is small and seismic design is large.But the degradation of durability will lower seismic quality.Ensuring the durability is the precondition of guaranteeing seismic quality.When the outburst earthquake detriment is recognized the durability degradation should be defended.The durability degradation not only increases the charge in maintenance and strengthening,but also reduces the seismic ability.The seismic performance requirement mainly is shown in guaranteeing the enough strength,stiffness,robustness and stability.The durability design mainly includes the requirements for concrete material,constructional measure and construction requirement
Design of new type of medical infrared temperature measuring instrument
目的:针对市场现有的测温仪的弊端,设计一种新型医用红外测温仪。方法:采用红外线温度传感器采集人体温度,以HT67F5640芯片为主控制器,通过A/D转换把检测的人体温度显示在液晶显示器(liquid crystal display,LCD)上。该仪器设计的电路包括主控制电路、电源电路、红外温度传感器电路、LCD驱动电路、按键电路、报警电路等;软件部分包括主程序,AD采集、LCD显示、蜂鸣器报警以及按键扫描等子程序。结果:该医用红外测温仪测量体温速度快、精度高、重复性好,医务人员反应良好。结论:该测温仪功耗低、使用方便、稳定性高、便于携带、各项参数优越,可以实现患者体温的快速检测。Objective To design a new type of medical infrared temperature measuring instrument.Methods The data on human body temperature were collected by the infrared temperature sensor with HT67F5640 as the main controller,and then displayed on the LCD through the A/D conversion.The circuits of the instrument included power supply circuit,infrared temperature sensor circuit,LCD drive circuit,key circuit,alarm circuit,etc.The software involved in the main program,AD acquisition subroutine,environment temperature compensation subroutine,calibration mode subroutine,etc.Results The instrument gained advantages in speed,precision,repeatability and response from medical staffs.Conclusion The medical infrared thermometer behaves well in low power consumption,easy operation,high stability and portability and etc,and is very suitable for the rapid detection of the patient's temperature
LED Color Analysis
主要对蓝光、绿光、白光lEd的色度特性进行分析,首先通过单色仪,分别测得蓝光、绿光、白光lEd的相对光谱功率分布并以色度学理论为基础,计算出光源主波长、色纯度、色温和显色指数.计算结果表明:蓝光lEd和绿光lEd主波长随标准光源的不同变化不大,色纯度比较高,分别在0.64和0.87左右,一般显色指数为-29和-14,显色性很差,不适合用来做照明光源.白光lEd主波长随标准光源的不同变化较大,色纯度相当低,接近0,一般显色指数为82,显色性很好,完全符合照明光源的要求.In order to study the color characteristics of light-emitting diode,the characteristics of blue,green and white LED colors are analyzed.Firstly,the spectral power distribution of blue,green,white LED is respectively measured by using the monochromator,and then on the basis of the theory chroma,the main light source wavelength,color purity,color temperature and color rendering index are calculated.The results show that blue LED and green LED dominant wavelengths change little with different standard light sources,and the color purities are relatively high,at 0.64 and 0.87,respectively,the general color-rendering is very poor for the index of-29 and-14,so these blue and green LED are not suitable to be used as lighting source.White LED dominant wavelength largely change with different standard light sources,and color purity is relatively low,near 0,color rendering is good for the general color-rendering index of 82, so white LED is in full conformance with the lighting requirements
对武汉地区渔业经济发展战略的探讨
<正> 湖北是我国的重点产鱼区,素有"鱼米之乡"美称。大力发展渔业,对于提高武汉、湖北人民的生活水平,具有重要意义。1980年胡耀邦同志视察湖北时指出:"农业上要注意水产,淡水养殖希望你们成为全国带头的省,而且要创造一点新经验。"最近童
二维扫描法测量连续型激光器远场分布
二维扫描法测量连续型激光器远场分布的原理是,用一个有一系列螺旋状分布小孔的旋转圆筒扫过被测光斑,以一维的旋转动作完成二维扫描。它能在10~(-3)—10~4瓦的功率范围内以10帧/秒的速度连续记录激光器二维的远场分布。此方法原则上适用于各种波长的连续输出激光器,特别适合于输出功率高、远场分布不规则并且随时间变化较快的连续激光器
LED非线性对基于正交频分复用可见光通信系统的影响
基于带有寄生参数的发光二极管(LED)Shockley方程,结合具有饱和特性的固态功率放大器的幅度传输模型,构建了可见光通信系统中LED的双向饱和非线性模型。基于该模型,通过蒙特-卡洛仿真分析了LED非线性对采用正交频分复用(OFDM)的可见光通信系统(VLC)性能的影响。分析结果表明OFDM的VLC系统性能受LEDI-V特性非线性、直流偏置电压、基带调制方式、调制信号切顶比率及方式的直接影响
Autonomous Flight Control and Simulation Study of Independent Developed Soft-wing UAV
软翼无人机由柔性冲压式翼伞通过绳索悬挂带有动力发生装置的无人车构成。由于软翼无人机自身的特殊结构,使之存在附加质量、柔性结构以及内部相对运动,这给软翼无人机数学建模和自主飞行控制的研究带来很大障碍。基于数学模型的自主飞行控制器设计,可以低成本、高效率地获取无人机自主飞行控制算法。基于自行研制的软翼无人机实体系统,建立了6自由度数学模型,设计了自主飞行控制器和视景仿真系统,实现了对软翼无人机的数值和视景的联合仿真,并通过航迹点飞行仿真验证了自主飞行控制器和视景仿真系统的有效性
Adaptive Guaranteed Cost Control for Yaw Dynamic of Small-scale Helicopter
提出了一种新的模型直升机航向控制算法。针对具有模型不确定性的直升机航向线性模型,提出了一种具有自适应机制的最优保性能控制器。该控制策略通过引入自适应机制降低固定增益控制器所固有的保守性,并且控制器的反馈增益应用线性矩阵不等式(LMIs)方法解得。理论分析和数字仿真表明所设计的控制器具有良好的鲁棒稳定性能
一种膜片的自动点焊装置
本实用新型公开了一种膜片的自动点焊装置,包括:机架、与所述机架转动配合且在顶面带有若干沿周向布置的定位套的分度转盘、用于向所述定位套内放置第一膜片的第一膜片供料机构、用于向处在定位套中的第一膜片上叠加第二膜片的第二膜片供料机构、用于焊接处在定位套中的第一膜片和第二膜片的点焊机构以及用于将完成焊接的第一膜片和第二膜片移出定位套的下料机构。本实用新型通过分度转盘、第一膜片供料机构、第二膜片供料机构、点焊机构、下料机构之间的相互配合,通过控制机构的控制,使得第一膜片与第二膜片的点焊工作完全自动化,且本实用新型操作简单、安全可靠,既能提高了工作效率高,又能保证点焊质量
- …
