13 research outputs found

    Study on the Application of Comprehensive Budget Management in WZ Power Supply Company

    Get PDF
    全面预算是指企业对一定期间的经营活动、投资活动、财务活动等作出的预算安排。全面预算作为一种全方位、全过程、全员参与编制与实施的预算管理模式,凭借其计划、协调、控制、激励、评价等综合管理功能,成为优化配置企业资源、提高管理水平、增强企业核心竞争力,实现企业发展战略的重要抓手。 近年来,国家电网公司正在为加快实现“两个转变”(转变公司发展方式、转变电网发展方式)的企业战略目标和创建世界一流电网、国际一流企业的宏伟愿景而奋斗。全面预算管理作为实现企业发展战略和经营目标的有效方法,实施内部控制的重要措施,实现对企业各项活动制约和激励的重要手段,成为电网企业实现更高层次、更高水平、更高质量发展的必然选...Comprehensive budget refers to the budget made by the enterprises for operating activities, investment activities, and financial activities in a certain period. As an all-around and whole-process budget management model with all-member participation in the preparation and implementation, comprehensive budget has became an important means of integrating and optimizing the allocation of corporate re...学位:会计硕士院系专业:厦门大学与厦门国家会计学院会计硕士专业学位联合教育中心(MPACC)_会计硕士(MPACC)学号:X200915705

    Studies on Curing Shrinkage of Liquid Optical Clear Adhesive

    No full text
    紫外光固化的液态光学胶固化过程中出现的体积收缩现象,严重影响其黏接强度和产品外观.系统研究了液态光学胶预聚物的种类、活性稀释剂的种类和用量、光引发剂的用量、光固化的类型等诸多因素对固化收缩率的影响.研究发现,以聚乙二醇二丙烯酸酯作为预聚物可明显降低固化收缩率.当添加的活性稀释剂官能度相同时,胶黏剂的固化收缩率随活性稀释剂相对分子质量的增加而减小;当活性稀释剂相对分子质量相近时,官能度增加,固化收缩率随之增大.而光引发剂的用量则对固化收缩率无明显影响.阳离子型胶黏剂的固化收缩率比自由基型的小,但硬度和黏接强度较低;而混杂型的固化收缩率则介于二者之间.The volume shrinkage during UV-curing of liquid optical clear adhesives(LOCA)had a serious effect on the adhesive strength and appearance of the product.In this paper,the effect of different factors,including types of active diluents,amounts of active diluents and photo-initiators,and UV-curing types,on the volume shrinkage for LOCA was systematically investigated.Based on the experiment,polyethylene glycol diacrylate as the prepolymer could significantly reduce the shrinkage.With the same functionality of the added active diluents,the shrinkage decreased when the molecular weights of the active diluents increased.When the molecular weights of active diluents were similar,the shrinkage increased with the increase of the functionality.The amount of photo-initiators had no significant effect on shrinkage.The shrinkage of cationic adhesives was smaller than that of radical adhesives,but the hardness and adhesion strength were relatively lower.The shrinkage of hybrid adhesives was in between in general

    Study on Activity Persistance of Polyester Polymercaptan Curing Agent

    No full text
    对比了聚醚型聚硫醇和2种聚酯型聚硫醇的活性寿命的差异.通过红外光谱、1 H-nMr和凝胶时间的测试表征聚硫醇的活性寿命.结果表明,以叔胺为促进剂时,以β-巯基丙酸为原料制备得到的聚酯型聚硫醇P(SH)6和聚醚型聚硫醇P(SH)3固化剂都有良好的活性寿命;而以α-巯基乙酸为原料制备得到的聚酯型聚硫醇P(SH)4固化剂存在活性下降的问题,2个月后完全失活.通过红外光谱、1 H-nMr表征活性下降前后其基团的变化提出了可能导致其活性下降的机理及解决的方法.The lifetime differences of polyether polymercaptans and two kinds of polyester polymercaptans were compared in this paper.The lifetime of polymercaptans curing agents was characterized by FT-IR,1 H-NMR and gelation time.The results revealed that polyester polymercaptans P(SH)6and polyether polymercaptans P(SH)3composed of 3-mercaptopropionic acid showed a long lifetime when using trialkylamine as accelerator,while polyester polymercaptans P(SH)4composed of 2-mercaptopropionic acid showed a decrease in curing activity and deactivated within two months.Possible mechanism of the decrease in curing activity was proposed based on the investigation of group changes during the deactivation by FT-IR and 1 H-NMR

    Measurement of integrated luminosity of data collected at 3.773 GeV by BESIII from 2021 to 2024

    No full text
    We present a measurement of the integrated luminosity e+e- of collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm = 3.773 GeV. The integrated luminosities of the datasets taken from December 2021 to June 2022, from November 2022 to June 2023, and from October 2023 to February 2024 were determined to be 4.995±0.019 fb-1, 8.157±0.031 fb-1, and 4.191±0.016 fb-1, respectively, by analyzing large angle Bhabha scattering events. The uncertainties are dominated by systematic effects, and the statistical uncertainties are negligible. Our results provide essential input for future analyses and precision measurements

    Amplitude analysis of the decays D0π+ππ+πD^0\rightarrow\pi^+\pi^-\pi^+\pi^- and D0π+ππ0π0D^0\rightarrow\pi^+\pi^-\pi^0\pi0

    No full text

    Determination of the number of ψ(3686) events taken at BESIII

    No full text
    The number of ψ(3686) events collected by the BESIII detector during the 2021 run period is determined to be (2259.3±11.1)×106 by counting inclusive ψ(3686) hadronic events. The uncertainty is systematic and the statistical uncertainty is negligible. Meanwhile, the numbers of ψ(3686) events collected during the 2009 and 2012 run periods are updated to be (107.7±0.6)×106 and (345.4±2.6)×106, respectively. Both numbers are consistent with the previous measurements within one standard deviation. The total number of ψ(3686) events in the three data samples is (2712.4±14.3)×10^

    Measurement of integrated luminosity of data collected at 3.773 GeV by BESIII from 2021 to 2024*

    No full text

    Prediction of Energy Resolution in the JUNO Experiment

    Get PDF
    International audienceThis paper presents the energy resolution study in the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3% at 1 MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The study reveals an energy resolution of 2.95% at 1 MeV. Furthermore, the study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data taking. Moreover, it provides a guideline in comprehending the energy resolution characteristics of liquid scintillator-based detectors
    corecore