83 research outputs found
An Inquiry into the Economic and Monetary Development of Toyama Prefecture during and after the War (1)
In Two Patients with Economic and Social Issues Stage I Giant Seminoma
The first case was in a 39-year-old man who complained of painless, left hemiscrotal swelling. The patient's serum β human chorionic gonadotropin (β-hCG) was elevated. A chest X-ray and computerized tomography (CT) did not reveal any abnormal findings. The patient underwent left high orchiectomy. The tumor weighed 440 g, and was pathologically diagnosed as a seminoma. The patient chose surveillance as the management strategy. Five months after the operation, the patient stopped attending his periodic checkups. After 21 months, the patient complained of abdominal distention. A CT showed a para-aortic lymph node mass. The patient achieved a complete response following chemotherapy with etoposide and cisplatin for 4 cycles. Three months after the adjuvant chemotherapy, hospital visits stopped again due to financial difficulties. The second case was in a 36-year-old man who complained of painless, right hemiscrotal swelling and difficulty in walking. Clinical examination revealed an adult-head-sized testicular tumor with elevation of serum lactic dehydrogenase (LDH) and β-hCG. A chest X-ray and abdominal CT did not reveal any abnormal findings. Despite a recommendation that the patient undergo immediate orchiectomy, the patient did not undergo surgery due to his unstable lifestyle. After 1 month, the patient presented with more difficulty in walking. The patient underwent right high orchiectomy. The tumor weighed 1, 926 g, and was pathologically diagnosed as a seminoma. The patient chose surveillance. There has been no recurrence for 19 months postoperatively
ディジタルソウインホウ ニ ヨル -18.5°Xカット スイショウ シンドウヘン ノ Qチ ソクテイ
A resonator set in a gap type holder in vacuum is connected to a radio frequency monitor and excited at 200 kHz of its second overtone at room temperature. The measurement is nerformed by sweeping the exciting frequency from the computer-controlled measurement system at a step of lmHz over about 1.3 Hz around the resonant frequency. A maximum Q-value of 2.2×10^7 is obtained by processing the data acquired from the measurement of the resonant curve of the resonator. This surpasses by 10% of the value estimated by Mason in Physical Acoustics, Vol. 1, Part A, p. 335, Academic Press, 1964
コウアツガス ヲ フウジタ 87Rbセル ノ 87Rbランプコウ ニ タイスル フィルタコウカ
Spectral profiles of the ^Rb D_1 line (λ=794.8 nm) passed through the cell are calculated to evaluate the filtering effect. Upon the calculatio, the broadening and shift of the pronle due to high pressure foreign gas are taken into account to make the cell absorb the unwanted spectral components emitted from the lamp. Filtering effect is discussed on the ^Rb cell containing a pressure of 300 to 900 Torr of N_2 or He gas
- …
