5 research outputs found

    Molecular characteristics of variation of galactokinase activity and development of method of galactokinase activity measurement

    No full text
    학위논문(박사)--서울대학교 대학원 :의학과 검사의학전공,2007.Docto

    UDP-galactose-4-epimerase(GALE) 결핍성 갈락토스혈증에 대한 한국인의 분자유전학적 성상 규명

    No full text
    학위논문(석사)--서울대학교 대학원 :의학과 검사의학전공,2004.Maste

    Schemes and Performance Evaluation Criteria of Korean Association of External Quality Assessment (KEQAS) for Improving Laboratory Testing

    No full text
    External quality assessment (EQA) is important for evaluating clinical laboratories and enhancing their testing quality. EQA schemes are variable; thus, it is crucial that the EQA organizers share their experiences to continuously improve the EQA scheme. The Korean Association of External Quality Assessment Service (KEQAS) has been the leading, authorized EQA institute for the standardization and quality management of laboratory testing in Korean medical institutions since 1976. The EQA scheme underwent a major change in 2016, and the number of EQA programs increased significantly since then. The key changes implemented in EQA scheme include a fully computerized assessment to accelerate feedback and unification of the testing and reporting methods. We provide an overview of the EQA schemes and performance evaluation criteria of the KEQAS and suggest directions for achieving the global harmonization of EQA

    Standardization Status of Total Cholesterol Concentration Measurement: Analysis of Korean External Quality Assessment Data

    No full text
    Background: Total cholesterol concentration measurement is important in the diagnosis of dyslipidemia and evaluation of cardiovascular disease risk factors. Measurement reliability for obtaining an accurate total cholesterol concentration requires procedure standardization. We evaluated the standardization status for total cholesterol concentration measurement through Korean external quality assessment (EQA) data analysis. Methods: This study involved 1,670 laboratories that participated in the EQA of total cholesterol concentration measurements in 2019 for 32 products from different manufacturers. The target concentrations of three quality control (QC) materials (samples A, B, and C) were measured using the reference method and compared with EQA data. The performance criteria for total cholesterol concentration measurement were based on the National Cholesterol Education Program guidelines, with +/- 3% inaccuracy. Results: The target values and inaccuracies of the QC material based on the reference method measurements were 254.65 +/- 7.64, 108.30 +/- 3.25, and 256.29 +/- 7.69 mg/dL (6.59 +/- 0.20, 2.80 +/- 0.08, and 6.63 +/- 0.20 mmol/L) for samples A, B, and C, respectively. The performance criteria were not met in 42.7% laboratories for sample A, 68.4% of laboratories for sample B, and 38.0% laboratories for sample C. Conclusions: Despite significant efforts to accurately measure total cholesterol concentrations, further actions are needed for measurement standardization. Manufacturers reporting values that differ from target values should check calibrator traceability; additional efforts to accurately measure total cholesterol concentrations are required for laboratories that use products from these manufacturers

    Immunosuppressive Drug Measurement by Liquid Chromatography Coupled to Tandem Mass Spectrometry: Interlaboratory Comparison in the Korean Clinical Laboratories

    No full text
    Background: Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories. This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. Methods: Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman's rank correlation coefficient (rho, rho) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. Results: The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (rho=0.334, P=0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5 degrees C storage (P=0.015 for 14 days; P=0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. Conclusions: LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus
    corecore