6 research outputs found

    Preparation of gold core-mesoporous iron-oxide shell nanoparticles and their application as dual MR/CT contrast agent in human gastric cancer cells

    No full text
    Multifunctional nano-systems are an enticing approach toward the design of nanoparticles with desired characteristics because of interactions between various components of the system. The combination of various imaging modalities often augments the advantages and simultaneously overcomes restrictions encountered by the individual techniques. This report describes the development of multifunctional gold core/iron oxide porous-shell nanoparticles (AuFe NPs) functionalized with matrix metalloproteinase peptide for targeted multi-mode magnetic resonance and computed tomography imaging. This study demonstrates that AuFe NPs simultaneously possess both T2-based contrast effect and X-ray attenuation properties in vitro. The drug loading capacity of porous iron oxide shell is also proposed.restrictio

    A prospective comparison of patient body image after robotic thyroidectomy and conventional open thyroidectomy in patients with papillary thyroid carcinoma

    No full text
    BACKGROUND: Body image is associated with self-esteem and identity and has a close relationship with quality of life (QoL). We compared the impact of surgical scars on the patient's perception of body image between conventional open thyroidectomy (OT) and robotic thyroidectomy (RT) in female papillary thyroid carcinoma patients. METHODS: From October 2009 to December 2010, we enrolled prospectively 116 papillary thyroid carcinoma patients who underwent total thyroidectomy at the Yonsei University Health System (Seoul, Korea). Of these 116 patients, 56 had OT and 60 RT. Their scars were assessed using the Vancouver Scar Scale (VSS), and psychometric properties were evaluated using the Body Image Scale (BIS) questionnaire postoperatively. Both groups were compared using cross-sectional and time-series methods. RESULTS: Mean age was significantly younger in the RT group. Regarding scar quality, the OT group showed superiority in scar pigmentation and the total VSS score during the early postoperative period, but the VSS score improved over time and was similar between both groups at 9 months. The RT group had better scores regarding most of the BIS items, a trend that remained relatively constant over time. In patients with noticeable scars (VSS ≥ 2) at 9 months, the RT group had better BIS scores regarding almost all items, including "self-conscious," "physical attractiveness," "feeling of less feminine," "sexual attractiveness," "dissatisfaction with body, scar and appearance when dressed," and "avoidance of people due to appearance."ope

    Lobectomy and Prophylactic Central Neck Dissection for Papillary Thyroid Microcarcinoma: Do Involved Lymph Nodes Mandate Completion Thyroidectomy?

    No full text
    BACKGROUND: The present study was designed to investigate the necessity of completion thyroidectomy for patients who underwent thyroid lobectomy for low-risk papillary thyroid microcarcinoma (PTMC) that was later pathologically diagnosed as central lymph node (CLN) metastasis. METHODS: Between 1986 and 2001, we assessed 551 patients who underwent thyroidectomy with prophylactic ipsilateral central compartment neck dissection, and 409 patients were followed-up completely. Thyroid lobectomy were performed in 281 and 128 patients, respectively. The patients were divided into two groups according to CLN metastasis. Clinicopathological profiles and follow-up details were investigated by retrospective chart review. RESULTS: The CLN-positive and -negative groups were comprised of 43 (15.2 %) and 238 patients (84.8 %), respectively. The mean ages of the two groups were not significantly different (p > 0.05). The mean tumor size of the CLN-positive group (6.8 mm) was significantly larger than that of the CLN-negative group (5.6 mm; p < 0.05). Microscopic capsular invasion was significantly higher in the CLN-positive group (51.2 vs. 23.9 %; p < 0.05). Overall, 21 patients (7.4 %, 21/281) experienced recurrence. Among these, 2 (4.7 %, 2/43) and 19 (8.0 %, 19/238) were in the CLN-positive and -negative groups, respectively. There was no significant correlation between CLN metastasis and tumor recurrence. CONCLUSIONS: Postoperative recurrence was lower in the CLN-positive group, and there was no significant correlation between CLN metastasis and tumor recurrence. Our results suggest that it is not necessary to perform completion thyroidectomy for PTMC patients who have undergone thyroid lobectomy and who have been pathologically diagnosed with CLN metastasis.ope

    The impact of body habitus on the surgical outcomes of transaxillary single-incision robotic thyroidectomy in papillary thyroid carcinoma patients

    No full text
    BACKGROUND: Robotic applications have achieved safe and precise thyroidectomy with notable cosmetic and functional benefits. This study was designed to document the influence of body habitus on robotic thyroidectomy in papillary thyroid carcinoma (PTC) patients. METHODS: From July 2009 to February 2010, 352 patients underwent robotic thyroidectomy using a gasless, transaxillary single-incision approach at Yonsei University Health System. Body habitus was described using body mass index category (normal weight, overweight, obese), neck length, shoulder width, and shoulder width to neck length ratios. The impact of body habitus on surgical outcomes was analyzed with respect to operation time, number of retrieved central nodes, bleeding amount, and postoperative complications. RESULTS: Of the 352 patients, 217 underwent less than total thyroidectomy and 135 underwent total thyroidectomy. Operative variables (i.e. operation times, bleeding amounts, and numbers of retrieved central nodes) showed no significant differences between three BMI groups for less than total thyroidectomy. However, total operation and working space times were longer for obese patients during total thyroidectomy. In particular, shoulder width was positively correlated with total operation time, working space time, console time, and number of retrieved central nodes. On the other hand, postoperative complications were not significantly different in the three BMI groups and showed no significant correlation with the other indices of body habitus. CONCLUSIONS: Standardized robotic thyroidectomy can be performed safely and feasibly in patients with a large body habitus despite longer operation times.ope

    Surgical complications after robotic thyroidectomy for thyroid carcinoma: a single center experience with 3,000 patients

    No full text
    BACKGROUND: Robotic thyroidectomy (RT), a new gasless, transaxillary approach developed by the Yonsei University group in Seoul, Korea, eliminates the need for a cervical incision. Since RT is technically complex and has a steep learning curve, the surgical complication rate may initially be higher than with conventional surgery. This study evaluated the complication rates of transaxillary RT and assessed ways to prevent surgical complications. METHODS: Between October 2007 and March 2013, 3,000 patients underwent RT for thyroid cancer in the Department of Surgery, Yonsei University College of Medicine at Severance Hospital, Seoul. The medical records of these patients were reviewed retrospectively, and surgical complications were assessed on the basis of clinical findings. RESULTS: The most common surgical complication was symptomatic hypocalcemia, of which 37.43 % cases were transient and 1.10 % permanent. Other surgical complications included recurrent laryngeal nerve injury (1.23 % transient, 0.27 % permanent), seroma (1.73 %), hematoma (0.37 %), chyle leakage (0.37 %), trachea injury (0.2 %), Horner's syndrome (0.03 %), carotid artery injury (0.03 %), and brachiocephalic vein injury (0.03 %). The technique-related complications, which were never seen in conventional open thyroidectomy, were axillary skin flap perforation (0.1 %), and traction injury of the arm on the side the lesion was located (0.13 %). CONCLUSIONS: Surgeons who have mastered standardized robotic surgical procedures and who understand potential complications and how to prevent them can perform RT safely.ope
    corecore