8 research outputs found
STM Observation of Au Particles Adsorbed on Si(111)-Clean Surface by PLD Method
To obtain important information for fabricating atomic-scale Au thin films that are used for biosensors, we have examined the flushing temperature for forming the Si(111) clean surface and observed the morphology of Au particles adsorbed by Pulsed Laser Deposition method on a Si(111)-7×7 surface by STM, which is supposed to be the initial stage of Au atomistic thin film formation. As the result of this study, it was found that flushing temperature must be controlled within 5℃ and we can fix the flushing requirement by STM images. Besides, we have estimated that Au particles are adsorbed on the position which is about 0.21 ± 0.03 nm away from the center of Si adatom.departmental bulletin pape
糖鎖生物学の新展開
α-1,3-フコース転移酵素cDNAの導入と強制発現により、L細胞のインテグリン依存性の接着が促進された。ヒト骨髄球系細胞に於て、ガングリオシドの合成を制御する酵素としてGM3を合成するシアル酸転移酵素とLc3Cerを合成するN-アセチルグルコサミン転移酵素を同定した。ヒト結腸癌組織においてシアリルLe^aの抗原を持つ糖鎖の構造を明かにした。ルウィス血液型陰性の個体に於て、FuT-III遺伝子の変異をヌクレオチドレベルで解明した。胃体部と胃前庭部に於て、消化管ムチンの硫酸化糖鎖の構造パターンが異なっていた。Gsl-5糖鎖を形成するβ-1、6-N-アセチルグルコサミン転移酵素を精製し、アミノ酸部分配列を明かにした。肝細胞膜の表層糖鎖末端β-ガラクトシドが肝細胞接着に関与し、この機構にC-型レクチンは関与しないと示唆された。成人型異染性脳白質変性症の原因となるアリルスルファタ-ゼAの新しい構造異常を見出した。ウシ精巣性ヒアルロニダーゼの糖転移反応を利用して、新しいハイブリッド型プロチオグリカンを作成した。ニワトリCa^依存性α-マンノシダ-ゼの特異性を解明した。マクロファ-ジレクチンのチロシン残基(Tyr5)がインタ-ナリゼイションに必須なことを明かにした。また、C-型レクチンの1つであるコンアグルチニンのcDNAおよびゲノムシークエンスを明かにした。Sophora japonica樹皮中のレクチンが損傷の修復に関与する可能性を指摘した。アルコール依存症患者血清に糖鎖欠損トランスフェリンを見出した。コンドロイチン硫酸のペプチドとの結合部位を合成した。ヒトマクロファージのレクチンcDNAを単離し、構造決定した。科学研究費補助金 研究種目:総合研究(A) 課題番号:03304050 研究代表者:村松 喬 研究期間:1991-1993年度research repor
Mean knee flexion angle versus percent cycle for 45 normal subjects, with a 95% bootstrap prediction band
<p><b>Copyright information:</b></p><p>Taken from "Comparison of two normative paediatric gait databases"</p><p>http://www.dynamic-med.com/content/6/1/8</p><p>Dynamic medicine : DM 2007;6():8-8.</p><p>Published online 17 Jul 2007</p><p>PMCID:PMC1947956.</p><p></p> For statistical purposes, the mean of each individual curve was removed prior to computation of the overall mean and bootstrap prediction bands
Mean results for knee flexion angles versus percent cycle using UNB's euler () and projected angle data (---) and San Diego projected angle data ()
<p><b>Copyright information:</b></p><p>Taken from "Comparison of two normative paediatric gait databases"</p><p>http://www.dynamic-med.com/content/6/1/8</p><p>Dynamic medicine : DM 2007;6():8-8.</p><p>Published online 17 Jul 2007</p><p>PMCID:PMC1947956.</p><p></p> For statistical purposes, the mean of each individual curve was removed prior to computation of the overall mean
Sagittal hip, knee, and ankle angles (+) versus percent cycle for a hypotonic subject, with 95% bootstrap prediction band
<p><b>Copyright information:</b></p><p>Taken from "Comparison of two normative paediatric gait databases"</p><p>http://www.dynamic-med.com/content/6/1/8</p><p>Dynamic medicine : DM 2007;6():8-8.</p><p>Published online 17 Jul 2007</p><p>PMCID:PMC1947956.</p><p></p> For statistical purposes, the mean of each individual curve was removed for the individual and mean data
Development of Focusing and Irradiating System for Laser-stimulated Desorption Spectrometer
Vacuum ultraviolet (VUV) with a wavelength of 100-200 nm has a photon energy of about 6-12 eV, which is higher than the binding energy of many substances, and has the feature of being able to break chemical bonds. We have applied these features to develop an analyzer named the Photon-stimulated Desorption Spectrometer. Since the spatial and temporal resolutions of this system are low due to adaption of incoherent light source, it is expected to improve by replacing the light source with an ultrashort pulsed VUV laser. In the present study, we have developed a focusing and irradiating system that enables various laser irradiation modes by overlapping multiple beams spatially and temporally. High-precision position control of the focusing and irradiating system is necessary for this purpose. Here, we used a number of micrometers with encoder that can be computercontrolled with a resolution of 1 μm to develop a double beam focusing and irradiating system using currently available ultrashort pulsed lasers with wavelengths of 800 nm and 400 nm. As a results, we confirmed that the smaller spot diameter was obtained by using the shorter wavelength. The spatial superposition can be performed within an accuracy range of ±3 μm, and the temporal superposition can be performed with an accuracy of 33 fs. Besides, interference fringes were obtained by angled irradiation of two light beams which can be expected to induce desorption in finer areas.departmental bulletin pape
