37 research outputs found

    Étude des grandeurs caractéristiques de la tache cathodique d'un arc électrique

    Full text link
    The cathode of an electric arc burning freely in air was studied during a half-wave of a sinusoidal, 50 Hz current. For mean intensities ranging from 500 to 2 000 A, five characteristic parameters for the cathode spot were determined : the mean radius a, the temperature T, the electric field E, the total current density J, and the fraction s of the current density due to electrons. The experimental measurement of the erosion of the cathode together with five simultaneous equations enabled the parameters above to be obtained for copper and silver electrodes. The first part of the results gives mean values. The second part shows the changes occuring in the cathode spot as a function of time for the half-wave of the current.On étudie la cathode d'un arc électrique brulant librement dans l'air pendant une demi-alternance d'un courant sinusoïdal de fréquence 50 Hz. Nous avons déterminé pour des intensités moyennes variant entre 500 et 2 000 A cinq grandeurs physiques caractéristiques de la tache cathodique : le rayon moyen a, la température T, le champ électrique E, la densité totale de courant J et la fonction s de la densité de courant due aux électrons. La mesure expérimentale de l'érosion de la cathode associée à un système de cinq équations a permis d'obtenir ces grandeurs pour des électrodes en cuivre et en argent. La première partie des résultats donne des valeurs moyennes, tandis que la deuxième partie montre l'évolution de la tache cathodique en fonction du temps pour la demi-alternance de courant

    Allergic contact dermatitis to costus: removal of haptens with polymers

    Full text link
    Costus oil, an iol isolated from a Composite, Saussurea lappa C., used in perfumery, is responsible of numerous cases of allergic contact dermatitis (ACD). The haptens incriminated are sesquiterpene lactones, costunolide and dehydrocostuslactone. These lactones can be removed from the oil by using a polymer, aminoethyl-polystyrene, to which they become bound: the passing solution is lactone-free. A group of guinea-pigs could be successfully sensitized (Freund Complete Adjuvant Test) to costus essential oil, while another group, injected in the same way with polymer-treated essential oil (i.e. lactones) could not be sensitized. This polymer therefore provides a means to render complex plant extracts non-allergic.</jats:p

    Are inter-model differences in AMIP-II near surface air temperature means and extremes explained by land surface energy balance complexity?

    No full text
    We use the Atmospheric Model Intercomparison Project (AMIP-II) experimental protocol to perform six ensemble simulations for four different modes of land surface energy balance complexity. We calculate the land-only mean, minimum and maximum temperature variance for each ensemble and compare these with AMIP-II results. We find no evidence that the surface energy balance complexity leads to systematic differences in the simulated mean, minimum or maximum temperature variance at the global scale, or in the zonal averages. We therefore conclude that the differences simulated by the AMIP-II models cannot be attributed to variations in surface energy balance complexity. Our results indicate that the simulation of mean temperature variance and the variance of extreme temperature are not limited by uncertainties in how to parameterize the surface energy balance, a conclusion that adds confidence to the use of climate models for detection and attribution studies.4 page(s
    corecore