2,336 research outputs found

    Comparison of rocket-borne probes for electron density measurements Quarterly status report no. 5, Aug. 1 - Oct. 31, 1965

    Get PDF
    Impedance, resonance, capacitance, electrostatic, and Langmuir probe performance for ionospheric electron density profil

    The test-retest reliability of centre of pressure measures in bipedal static task conditions - A systematic review of the literature

    Get PDF
    Summary of background data: The analysis of centre of pressure (COP) excursions is used as an index of postural stability in standing. Conflicting data have been reported over the past 20 years regarding the reliability of COP measures and no standard procedure for COP measure use in study design has been established. Search methods: Six online databases (January 1980 to February 2009) were systematically searched followed by a manual search of retrieved papers. Results: Thirty-two papers met the inclusion criteria. The majority of the papers (26/32, 81.3%) demonstrated acceptable reliability. While COP mean velocity (mVel) demonstrated variable but generally good reliability throughout the different studies (r= 0.32-0.94), no single measurement of COP appeared significantly more reliable than the others. Regarding data acquisition duration, a minimum of 90 s is required to reach acceptable reliability for most COP parameters. This review further suggests that while eyes closed readings may show slightly higher reliability coefficients, both eyes open and closed setups allow acceptable readings under the described conditions (r≥0.75). Also averaging the results of three to five repetitions on firm surface is necessary to obtain acceptable reliability. A sampling frequency of 100. Hz with a cut-off frequency of 10. Hz is also recommended. No final conclusion regarding the feet position could be reached. Conclusions: The studies reviewed show that bipedal static COP measures may be used as a reliable tool for investigating general postural stability and balance performance under specific conditions. Recommendations for maximizing the reliability of COP data are provided

    Excitation of plasma resonances by a small pulsed dipole

    Get PDF
    Resonant oscillation decay excited by pulsed dipole in collisionless plasm

    Magneto-optical signatures of a cascade of transitions in La2x_2-xBax_xCuO4_4

    Full text link
    Recent experiments in the original cuprate high temperature superconductor, La2x_2-xBax_xCuO4_4, have revealed a remarkable sequence of transitions [1]. Here we investigate such crystals with Kerr effect which is sensitive to time-reversal-symmetry breaking (TRSB). Concurrent birefringence measurements accurately locate the structural phase transitions from high-temperature tetragonal to low temperature orthorhombic, and then to lower temperature tetragonal, at which temperature a strong Kerr signal onsets. Hysteretic behavior of the Kerr signal suggests that TRSB occurs well above room temperature, an effect that was previously observed in high quality YBa2_2Cu3_3O$_{6+x} crystals [2].Comment: 5 pages, 4 figure

    Thermo-optic noise in coated mirrors for high-precision optical measurements

    Get PDF
    Thermal fluctuations in the coatings used to make high-reflectors are becoming significant noise sources in precision optical measurements and are particularly relevant to advanced gravitational wave detectors. There are two recognized sources of coating thermal noise, mechanical loss and thermal dissipation. Thermal dissipation causes thermal fluctuations in the coating which produce noise via the thermo-elastic and thermo-refractive mechanisms. We treat these mechanisms coherently, give a correction for finite coating thickness, and evaluate the implications for Advanced LIGO

    Thermal noise in half infinite mirrors with non-uniform loss: a slab of excess loss in a half infinite mirror

    Get PDF
    We calculate the thermal noise in half-infinite mirrors containing a layer of arbitrary thickness and depth made of excessively lossy material but with the same elastic material properties as the substrate. For the special case of a thin lossy layer on the surface of the mirror, the excess noise scales as the ratio of the coating loss to the substrate loss and as the ratio of the coating thickness to the laser beam spot size. Assuming a silica substrate with a loss function of 3x10-8 the coating loss must be less than 3x10-5 for a 6 cm spot size and a 7 micrometers thick coating to avoid increasing the spectral density of displacement noise by more than 10%. A similar number is obtained for sapphire test masses.Comment: Passed LSC (internal) review. Submitted to Phys. Rev. D. (5/2001) Replacement: Minor typo in Eq. 17 correcte

    The multiple ionospheric probe Auroral ionospheric report

    Get PDF
    Multiple impedance and resonance probe payload for ionospheric property observation in Nike- Apache rocke

    Quantum Zeno effect in a probed downconversion process

    Full text link
    The distorsion of a spontaneous downconvertion process caused by an auxiliary mode coupled to the idler wave is analyzed. In general, a strong coupling with the auxiliary mode tends to hinder the downconversion in the nonlinear medium. On the other hand, provided that the evolution is disturbed by the presence of a phase mismatch, the coupling may increase the speed of downconversion. These effects are interpreted as being manifestations of quantum Zeno or anti-Zeno effects, respectively, and they are understood by using the dressed modes picture of the device. The possibility of using the coupling as a nontrivial phase--matching technique is pointed out.Comment: 11 pages, 4 figure
    corecore