117 research outputs found

    Simulation of the influence of hydrophones used for the characterization of pressure field distribution in low frequency, high power ultrasonic reactor vessels

    Get PDF
    This paper describes the use of a finite element (FE) modeling approach to investigate the influence of different hydrophone designs in laboratory scale reactor vessels. In addition to conventional PVDF membrane and piezoceramic hydrophone, the performance of a conceptual array hydrophone, comprising a 2D matrix of PVDF array elements, will be simulated. The FE modeling concentrates on two issues: the disturbance to the field through the introduction of each hydrophone configuration; and their suitability and response to measuring non-linear effects. To simplify the model the ultrasonic transducer is not directly represented. Here, a pressure loading function is used as the excitation technique, with a sawtooth waveform applied for the simulation of the non-linear detection capability of each hydrophone configuration. The results from the simulation programme demonstrate that the dynamics of the reactor vessel are critical to optimize the performance of the ultrasonic system. In addition, the introduction of a hydrophone alters the wave propagation, and hence the field distribution beyond a given probe location. Nevertheless, the spatial pressure distribution at the active area remains reasonably accurate if within the useable bandwidth of the device. Accordingly, the broadband nature of the membrane device is suited to operation in both the linear and non-linear regimes, with the PVDF array membrane device offering a fast, convenient measurement of the pressure field distribution for industrial applications

    Ultrasonic wave propagation in cylindrical vessels and implications for ultrasonic reactor design

    Get PDF
    Reactors in which processes are enhanced by ultrasound are hampered by the lack of a theoretical framework on their design. Simulation results of ultrasonic wave propagation in a cylindrical geometry are presented in this work, which are then used to develop guidelines for the design of ultrasonic reactors. These guidelines are used to design a new type of reactor with a novel geometry, operating at a frequency of 27kHz, 39kHz and 82kHz. This reactor is characterized using Weissler's reaction dosimetr

    Investigating the influence of the constituent materials on the performance of periodic piezoelectric composite arrays

    Get PDF
    This paper describes a theoretical investigation into the influence of the constituent materials on periodic composite array transducer performance. A finite element (FE) model, configured in PZFlex, is used to analyze the performance of a wedge coupled array transducer operating into a steel component. Here, the improvements offered by new single crystal piezoelectric materials are compared to standard PZT‐based configurations. In addition, new passive polymer materials, possessing low longitudinal loss and high shear loss, are evaluated for their potential to significantly reduce inter‐element mechanical cross talk. The FE results illustrate the potential for the next generation of array transducers incorporating these new materials and this is highlighted in the A‐scan predictions from simulated defects

    An annular array with fiber composite microstructure for far field NDT imaging applications

    Get PDF
    This paper describes the design and fabrication of a reduced element count annular array for far field NDT imaging applications, built with a random fiber piezoelectric composite microstructure. An annular array design is considered, spatially it offers axi-symmetric layout while reducing number of array elements, which could potentially result in a significant reduction in the cost and complexity of building an ultrasonic volumetric imaging system. Modelling and preliminary experimental results are presented to evaluate the feasibility of this approach

    A 2D ultrasonic array design incorporating hexagonal-shaped elements for NDE applications

    Get PDF
    Contemporary 2D Ultrasonic arrays suffer from low SNR and limited steering capabilities. Yet, there is a great desire in the industry to increase the operational frequency, in order to enhance their volumetric imaging resolution. State-of-the art arrays use an orthogonal matrix of rectangular elements as this is a natural step forward from the conventional 1D array structure. The objective of this work is to evaluate properties of triangular, rather than rectangular ceramic pillars in a 1-3 connectivity piezoelectric composite for application in a hexagonal-element 2D array. A 3MHz prototype device exploiting new hexagonal substructure have been manufactured. Measured mechanical cross-coupling level is -21.9dB between neighbouring hexagonal elements, providing validation of simulation result. Corroboration between measured and FE modelled device behaviour is demonstrated

    Particle sizing in the process industry using Hertz-Zener impact theory and acoustic emission spectra

    Get PDF
    The cost of implementing real-time monitoring and control of industrial processes is a significant barrier for many companies. Acoustic techniques provide complementary information to optical spectroscopic sensors and have a number of advantages: they are relatively inexpensive, can be applied non-invasively, are non-destructive, multi-point measurements are possible, opaque samples can be analysed in containers that are made from opaque materials (e.g. steel or concrete) and the analysis can be conducted in real-time. In this paper a new theoretical model is proposed which describes the transport of particles in a stirred reactor, their collision with the reactor walls, the subsequent vibrations which are then transmitted through the vessel walls, and their detection by an ultrasonic transducer. The particle-wall impact is modelled using Hertz-Zener impact theory. Experimental data is then used in conjunction with this (forward) model to form an inverse problem for the particle size distribution using a least squares cost function. Application of an integral smoothing operator to the power spectra greatly enhances the accuracy and robustness of the approach. One advantage of this new approach is that since it operates in the frequency domain, it can cope with the industrially relevant case of many particle-wall collisions. The technique will be illustrated using data from a set of controlled experiments. In the first instance a set of simplified experiments involving single particles being dropped in air onto a substrate are utilised. The second set of experiments involves particles in a carrier fluid being stirred in a reactor vessel. In each case the approach is able to successfully recover the associated particle size

    Total focussing method for volumetric imaging in immersion non destructive evaluation

    Get PDF
    This paper describes the use of a 550 (25x22) element 2MHz 2D piezoelectric composite array in immersion mode to image an aluminum test block containing a collection of artificial defects. The defects included a 1mm diameter side-drilled hole, a collection of 1mm slot defects with varying degrees of skew to the normal and a flat bottomed hole. The data collection was carried out using the full matrix capture; a scanning procedure was developed to allow the operation of the large element count array through a conventional 64-channel phased array controller. A 3D TFM algorithm capable of imaging in a dual media environment was implemented in MATLAB for the offline processing the raw scan data. This algorithm facilitates the creation of 3D images of defects while accounting for refraction effects at material boundaries. In each of the test samples interrogated the defects, and their spatial position, are readily identified using TFM. Defect directional information has been characterized using VTFM for defect exhibiting angles up to and including 45o of skew

    Teaching and learning analogue electronics in undergraduate courses : preliminary findings from the ETL project

    Get PDF
    This paper describes ongoing research into the teaching and learning of analogue electronics in three course units at two research-intensive universities. It draws on students' experiences of teaching and learning in analogue course units to explore the nature of the learning they were undertaking and examines the teaching-learning activities they found most supportive of their studying

    Airborne broad-beam emitter from a capacitive transducer and a cylindrical structure

    Get PDF
    Beamwidth broadening of an ultrasonic air-coupled transducer is performed by an emitter constituted of an electrostatic transducer and of a cylinder with an opening at the top covering the surface of the transducer. The acoustic emission is thus forced through a hole smaller than the diameter of the transducer’s surface. In particular, a cylinder with an upper diameter of 10mm and a height of 5mm ensures the beam pattern of the final emitter is broad across a wide frequency range. Sound attenuation is reduced and lobes in the transducer’s beam pattern are cancelled. Beam broadening can improve range estimation techniques and ultrasonic sonar as a wider area can be inspected with one emission with no need for scanning

    Data-driven analysis of ultrasonic pressure tube inspection data

    Get PDF
    Pressure tubes are critical components of the CANDU reactors and other pressurized heavy water type reactors, as they contain the nuclear fuel and the coolant. Manufacturing flaws, as well as defects developed during the in-service operation, can lead to coolant leakage and can potentially damage the reactor. The current inspection process of these flaws is based on manually analyzing ultrasonic data received from multiple probes during planned, statutory outages. Recent advances on ultrasonic inspection tools enable the provision of high resolution data of significantly large volumes. This is highlighting the need for an efficient autonomous signal analysis process. Typically, the automation of ultrasonic inspection data analysis is approached by knowledge-based or supervised data-driven methods. This work proposes an unsupervised data-driven framework that requires no explicit rules, nor individually labeled signals. The framework follows a two-stage clustering procedure that utilizes the DBSCAN density-based clustering algorithm and aims to provide decision support for the assessment of potential defects in a robust and consistent way. Nevertheless, verified defect dimensions are essential in order to assess the results and train the framework for unseen defects. Initial results of the implementation are presented and discussed, with the method showing promise as a means of assessing ultrasonic inspection data
    corecore