26 research outputs found

    High sensitivity organic inorganic hybrid X-ray detectors with direct transduction and broadband response

    Get PDF
    X-ray detectors are critical to healthcare diagnostics, cancer therapy and homeland security, with many potential uses limited by system cost and/or detector dimensions. Current X-ray detector sensitivities are limited by the bulk X-ray attenuation of the materials and consequently necessitate thick crystals (~1 mm-1 cm), resulting in rigid structures, high operational voltages and high cost. Here we present a disruptive, flexible, low cost, broadband, and high sensitivity direct X-ray transduction technology produced by embedding high atomic number bismuth oxide nanoparticles in an organic bulk heterojunction. These hybrid detectors demonstrate sensitivities of 1712 µC mGy-1 cm-3 for "soft" X-rays and ~30 and 58 µC mGy-1 cm-3 under 6 and 15 MV "hard" X-rays generated from a medical linear accelerator; strongly competing with the current solid state detectors, all achieved at low bias voltages (-10 V) and low power, enabling detector operation powered by coin cell batteries

    High charge-carrier mobilities in blends of poly(triarylamine) and TIPS-pentacene leading to better performing X-ray sensors

    No full text
    A new class of X-ray sensor – in which there is a blend of poly(triarylamine) (PTAA) and 6,13-bis(triisopropylsilylethynyl) (TIPS)-pentacene in the active layer of a diode structure – has been developed. The crystalline pentacene provides a fast route for charge carriers and leads to enhanced performance of the sensor. The first time-of-flight charge-carrier mobility measurement of this blend is reported. The mobility of PTAA and TIPS-pentacene in a 1:25 molar ratio was found to be 2.2 × 10−5 cm2 V−1 s−1 (averaged for field strengths between 3 × 104 and 4 × 105 V cm−1), which is about 17 times higher than that obtained in PTAA over the same range of field strengths. This higher mobility is correlated with a fourfold increase in the X-ray detection sensitivity in the PTAA:TIPS-pentacene devices

    High charge-carrier mobilities in blends of poly(triarylamine) and TIPS-pentacene leading to better performing X-ray sensors

    Get PDF
    A new class of X-ray sensor – in which there is a blend of poly(triarylamine) (PTAA) and 6,13-bis(triisopropylsilylethynyl) (TIPS)-pentacene in the active layer of a diode structure – has been developed. The crystalline pentacene provides a fast route for charge carriers and leads to enhanced performance of the sensor. The first time-of-flight charge-carrier mobility measurement of this blend is reported. The mobility of PTAA and TIPS-pentacene in a 1:25 molar ratio was found to be 2.2 × 10−5 cm2 V−1 s−1 (averaged for field strengths between 3 × 104 and 4 × 105 V cm−1), which is about 17 times higher than that obtained in PTAA over the same range of field strengths. This higher mobility is correlated with a fourfold increase in the X-ray detection sensitivity in the PTAA:TIPS-pentacene devices

    Achieving a Stable Time Response in Polymeric Radiation Sensors under Charge Injection by X-rays

    No full text
    Existing inorganic materials for radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, lack of tissue equivalence toxicity, and mechanical inflexibility. As an alternative to inorganics, poly(triarylamine) (PTAA) diodes have been evaluated for their suitability for detecting radiation via the direct creation of X-ray induced photocurrents. A single layer of PTAA is deposited on indium tin oxide (ITO) substrates, with top electrodes selected from Al, Au, Ni, and Pd. The choice of metal electrode has a pronounced effect on the performance of the device; there is a direct correlation between the diode rectification factor and the metal-PTAA barrier height. A diode with an Al contact shows the highest quality of rectifying junction, and it produces a high X-ray photocurrent (several nA) that is stable during continuous exposure to 50 kV Mo K alpha X-radiation over long time scales, combined with a high signal-to-noise ratio with fast response times of less than 0.25 s. Diodes with a low band gap, 'Ohmic' contact, such as ITO/PTAA/Au, show a slow transient response. This result can be explained by the build-up of space charge at the metal-PTAA interface, caused by a high level of charge injection due to X-ray-induced carriers. These data provide new insights into the optimum selection of metals for Schottky contacts on organic materials, with wider applications in light sensors and photovoltaic devices
    corecore