6,235 research outputs found

    Development and Application of Wide Bandwidth Magneto-Resistive Sensor Based Eddy Current Probe

    Get PDF
    The integration of magneto-resistive sensors into eddy current probes can significantly expand the capabilities of conventional eddy current nondestructive evaluation techniques. The room temperature solid-state sensors have typical bandwidths in the megahertz range and resolutions of tens of microgauss. The low frequency sensitivity of magneto-resistive sensors has been capitalized upon in previous research to fabricate very low frequency eddy current sensors for deep flaw detection in multilayer conductors. In this work a modified probe design is presented to expand the capabilities of the device. The new probe design incorporates a dual induction source enabling operation from low frequency deep flaw detection to high frequency high resolution near surface material characterization. Applications of the probe for the detection of localized near surface conductivity anomalies are presented. Finite element modeling of the probe is shown to be in good agreement with experimental measurements

    Eddy Current System and Method for Crack Detection

    Get PDF
    An eddy current system and method enables detection of sub-surface damage in a cylindrical object. The invention incorporates a dual frequency, orthogonally wound eddy current probe mounted on a stepper motor-controlled scanning system. The system is designed to inspect for outer surface damage from the interior of the cylindrical object

    Mutation of Arabidopsis SPLICEOSOMAL TIMEKEEPER LOCUS1 Causes Circadian Clock Defects

    Get PDF
    The circadian clock plays a crucial role in coordinating plant metabolic and physiological functions with predictable environmental variables, such as dusk and dawn, while also modulating responses to biotic and abiotic challenges. Much of the initial characterization of the circadian system has focused on transcriptional initiation, but it is now apparent that considerable regulation is exerted after this key regulatory step. Transcript processing, protein stability, and cofactor availability have all been reported to influence circadian rhythms in a variety of species. We used a genetic screen to identify a mutation within a putative RNA binding protein (SPLICEOSOMAL TIMEKEEPER LOCUS1 [STIPL1]) that induces a long circadian period phenotype under constant conditions. STIPL1 is a homolog of the spliceosomal proteins TFP11 (Homo sapiens) and Ntr1p (Saccharomyces cerevisiae) involved in spliceosome disassembly. Analysis of general and alternative splicing using a high-resolution RT-PCR system revealed that mutation of this protein causes less efficient splicing of most but not all of the introns analyzed. In particular, the altered accumulation of circadian-associated transcripts may contribute to the observed mutant phenotype. Interestingly, mutation of a close homolog of STIPL1, STIP-LIKE2, does not cause a circadian phenotype, which suggests divergence in function between these family members. Our work highlights the importance of posttranscriptional control within the clock mechanism. © 2012 American Society of Plant Biologists. All rights reserved

    Magnetoresistive flux focusing eddy current flaw detection

    Get PDF
    A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage

    Adaptive feedback analysis and control of programmable stimuli for assessment of cerebrovascular function

    No full text
    The assessment of cerebrovascular regulatory mechanisms often requires flexibly controlled and precisely timed changes in arterial blood pressure (ABP) and/or inspired CO2. In this study, a new system for inducing variations in mean ABP was designed, implemented and tested using programmable sequences and programmable controls to induce pressure changes through bilateral thigh cuffs. The system is also integrated with a computer-controlled switch to select air or a CO2/air mixture to be provided via a face mask. Adaptive feedback control of a pressure generator was required to meet stringent specifications for fast changes, and accuracy in timing and pressure levels applied by the thigh cuffs. The implemented system consists of a PC-based signal analysis/control unit, a pressure control unit and a CO2/air control unit. Initial evaluations were carried out to compare the cuff pressure control performances between adaptive and non-adaptive control configurations. Results show that the adaptive control method can reduce the mean error in sustaining target pressure by 99.57 % and reduce the transient time in pressure increases by 45.21 %. The system has proven a highly effective tool in ongoing research on brain blood flow control

    Comorbidities only account for a small proportion of excess mortality after fracture: A record linkage study of individual fracture types

    Get PDF
    Background: Non-hip non-vertebral fractures (NHNV) constitute the majority of osteoporotic fractures but few studies have examined the association between these fractures, co-morbidity and mortality. Objective: To examine the relationship between individual non-hip non-vertebral fractures, co-morbidities and mortality. Methods: Prospective population-based cohort of 267,043 subjects (45 and Up Study, Australia) had baseline questionnaires linked to hospital administrative and all-cause mortality data from 2006 - 2013. Associations between fracture and mortality examined using multivariate, time dependent Cox models, adjusted for age, prior fracture, body mass index, smoking and co-morbidities (cardiovascular disease, diabetes, stroke, thrombosis and cancer) and survival function curves. Population attributable fraction calculated for each level of risk exposure. Results: During 1,490,651 person-years, women and men experienced 7,571 and 4,571 fractures and 7,064 deaths and 11,078 deaths, respectively. In addition to hip and vertebral fractures, pelvis, humerus, clavicle, rib, proximal tibia/fibula, elbow and distal forearm fractures in both sexes, and ankle fractures in men, were associated with increased multivariable adjusted mortality hazard ratios ranging from 1.3 to 3.4. Co-morbidity independently added to mortality such that a woman with a humeral fracture and one co-morbidity had a similarly reduced 5 year survival to that of a woman with a hip fracture and no co-morbidities. Population mortality attributable to any fracture without co-morbidity was 9.2% in women and 5.3% in men. Conclusion: All proximal non-hip, non-vertebral fractures in women and men were associated with increased mortality risk. Co-existent co-morbidities independently further increased mortality. Population attributable risk for mortality for fracture was similar to cardiovascular disease and diabetes, highlighting their importance and potential benefit for early intervention and treatment

    The detection and photometric redshift determination of distant galaxies using SIRTF's Infrared Array Camera

    Get PDF
    We investigate the ability of the Space Infrared Telescope Facility's Infrared Array Camera to detect distant (z ~ 3)galaxies and measure their photometric redshifts. Our analysis shows that changing the original long wavelength filter specifications provides significant improvements in performance in this and other areas.Comment: 28 pages incl 12 figures; to appear in June 1999 PASP. Fig.12 replaced with corrected versio

    Detection of impaired cerebral autoregulation improves by increasing arterial blood pressure variability

    No full text
    Although the assessment of dynamic cerebral autoregulation (CA) based on measurements of spontaneous fluctuations in arterial blood pressure (ABP) and cerebral blood flow (CBF) is a convenient and much used method, there remains uncertainty about its reliability. We tested the effects of increasing ABP variability, provoked by a modification of the thigh cuff method, on the ability of the autoregulation index to discriminate between normal and impaired CA, using hypercapnia as a surrogate for dynamic CA impairment. In 30 healthy volunteers, ABP (Finapres) and CBF velocity (CBFV, transcranial Doppler) were recorded at rest and during 5% CO(2) breathing, with and without pseudo-random sequence inflation and deflation of bilateral thigh cuffs. The application of thigh cuffs increased ABP and CBFV variabilities and was not associated with a distortion of the CBFV step response estimates for both normocapnic and hypercapnic conditions (P=0.59 and P=0.96, respectively). Sensitivity and specificity of CA impairment detection were improved with the thigh cuff method, with the area under the receiver-operator curve increasing from 0.746 to 0.859 (P=0.031). We conclude that the new method is a safe, efficient, and appealing alternative to currently existing assessment methods for the investigation of the status of CA
    corecore