610 research outputs found
Current results and remaining challenges of trans-catheter aortic valve replacement expansion in intermediate and low risk patients
TAVR has become the standard treatment in patients at increased surgical risk (STS or EuroSCORE II 654% or logistic EuroSCORE I 65 10% or other risk factors not included in these scores such as frailty, porcelain aorta, sequelae of chest radiation) and it is increasingly being performed in patients at intermediate to low (STS or EuroSCORE II <4% or logistic EuroSCORE I < 10%) surgical risk. Although non-inferiority has been demonstrated in intermediate and low-risk patients, several challenges need to be addressed before expansion to younger patients. Current trends, trials results, and remaining challenges are summarized and discussed in this review
Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed.
OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves.
DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves.
MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class.
RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008).
CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography
The non-technical skills needed by graduates of technical colleges in metalwork technology
This study centered on the views of the professionals about the non-technical skills considered crucial as recruitment prerequisite among graduates of metalwork technology from technical and vocational institutions in Nigeria. It will also examine the possibility of integrating these skills into the curriculum. The study made use of the survey research design. One research question guided the study. The population for the study comprised metalwork technology professionals in Ogun State, Southwestern Nigeria. A 36-item questionnaire was the instrument used for data collection. The instrument was validated by experts from the University of Lagos (UNILAG). The reliability of the instrument was determined using Cronbach Alpha and the reliability index which stood at 0.79. The data collected were analysed using mean statistic and standard deviation. The study revealed that professionals placed great importance on communication skills, problem-solving skills, teamwork skills and self-management qualities among others, as important recruitment prerequisite among graduates of metalwork technology from technical and vocational institutions in Nigeria. The study concludes with the suggestions that non-technical skills should be integrated into the curriculum particularly in the field of metalwork technology in technical colleges. Students should be familiar with the employers’ recruitment criteria while they are still in schools in order to equip them with the necessary skills needed for employment
The acute haemodynamic effect of the MitraClip therapy: afterload mismatch evaluation in functional mitral regurgitation
n/
211 * CLINICAL AND ANATOMICAL PREDICTORS OF MITRACLIP THERAPY FAILURE FOR FUNCTIONAL MITRAL REGURGITATION
n/
Rationale and design of the prevail global trial program evaluating the prevail drug-coated balloon in patients with in-stent restenosis and de novo small vessel disease
\ua9 2025 The AuthorsBackground and Rationale: In-stent restenosis (ISR) remains the leading cause of treatment failure following percutaneous coronary intervention (PCI) with contemporary drug-eluting stents. Especially in small caliber coronary arteries, restenosis is common following PCI and represents a treatment challenge. Drug-coated balloons (DCB) are an attractive alternative to stents for treatment of both ISR and small vessel disease. The safety and efficacy of the Prevail DCB will be assessed for (1) the treatment of ISR and (2) de novo lesions in small vessels. Trial Design: Prevail Global is a prospective, international, dual cohort clinical study enrolling (1) patients undergoing PCI for ISR in a randomized controlled trial (1:1) design comparing the Prevail DCB versus an FDA-approved DCB (AgentTM, Boston Scientific Corporation, Natick MA), and (2) patients with de novo small vessel disease undergoing PCI with the Prevail DCB as part of a single-arm study compared with a historical control. The primary endpoint is target lesion failure, defined as a composite of cardiac death, target vessel myocardial infarction, or clinically-driven target lesion revascularization at 12 months post procedure. Patient follow-up is planned for 1 month, 6 months, and yearly through 5 years. Enrollment is expected to start in early 2025. Conclusions: The Prevail Global study will directly assess the safety and efficacy of the Prevail DCB for the treatment of ISR and de novo small vessel lesions. Trial Registration: Prevail Global, NCT06535854, is registered at https://clinicaltrials.gov/study/NCT06535854
Recommended from our members
Defining a new standard for IVUS optimized drug eluting stent implantation: The PRAVIO study
ObjectivesPreliminary Investigation to the Angiographic Versus IVUS Optimization Trial is a single center prospective observational intravascular ultrasound (IVUS) guided stent implantation study assessing new criteria for optimal drug eluting stent (DES) deployment.BackgroundIVUS assessment of DES often reveals underexpansion and malapposition. Optimal stent deployment is currently poorly defined and previous criteria may not be suitable in long and complex lesions.MethodsOptimization was defined as achieving >/or 70% of the cross-sectional area (CSA) of the postdilation balloon. This criterion was applied in 113 complex lesions. The size of this balloon was calculated according to vessel media-to-media diameters at various sites inside the stented segment. The IVUS guided treated lesions were matched according to diabetes, vessel type, reference vessel diameter, minimum lumen diameter (MLD), and lesion length with a group of angiographic treated lesions to compare final MLD achieved.ResultsMean minimum stent CSA according to the postdilation balloon utilized was 4.62 mm(2), 6.26 mm(2), 7.87 mm(2), and 9.87 mm(2) for 2.5 mm, 3.0 mm, 3.5 mm, and 4 mm balloons, respectively. Final MLD (mm) was significantly larger in the IVUS compared to the angiographic-guided group (3.09 +/- 0.50 vs. 2.67 +/- 0.54; P < 0.0001). There were no procedural complications related to IVUS use.ConclusionsWe propose new IVUS criteria based on vessel remodeling that results in an increment in the final MLD, compared to angiographic guidance, which is much larger than any previously published study. This criterion seems to be safely achievable. A proposed randomized study (angiographic vs. IVUS optimization trial) has been launched to test these concepts
Recommended from our members
Aortic Stenosis Management in Patients With Acute Hip Fracture
The treatment of severe aortic stenosis (SAS) has evolved rapidly with the advent of minimally invasive structural heart interventions. Transcatheter aortic valve replacement has allowed patients to undergo definitive SAS treatment achieving faster recovery rates compared to valve surgery. Not infrequently, patients are admitted/diagnosed with SAS after a fall associated with a hip fracture (HFx). While urgent orthopedic surgery is key to reduce disability and mortality, untreated SAS increases the perioperative risk and precludes physical recovery. There is no consensus on what the best strategy is either hip correction under hemodynamic monitoring followed by valve replacement or preoperative balloon aortic valvuloplasty to allow HFx surgery followed by valve replacement. However, preoperative minimalist transcatheter aortic valve replacement may represent an attractive strategy for selected patients. We provide a management pathway that emphasizes an early multidisciplinary approach to optimize time for hip surgery to improve orthopedic and cardiovascular outcomes in patients presenting with HFx-SAS
Atypical ST-Segment-Elevation Myocardial Infarction Presentation in Patients With COVID-19 at a High-Volume Center in New York City
Atypical presentations of ST-segment-elevation myocardial infarction (STEMI) have been reported in patients who have COVID-19. We have seen this occurrence in our center in Bronx, New York, where multitudes of patients sought treatment for the coronavirus. We studied the prevalence of atypical STEMI findings among patients with COVID-19 who presented during the first 2 months of the pandemic.
Consistent with previous reports, 4 of our 10 patients with COVID-19 and STEMI had no identifiable culprit coronary lesion; rather, they often had diffuse ST-segment elevations on surface electrocardiograms along with higher levels of D-dimer and inflammatory markers. In contrast, 32 of 33 patients without COVID-19 (97%) had a culprit lesion. The patients with COVID-19 and a culprit lesion more often needed thrombectomy catheterization and administration of glycoprotein IIb/IIIa inhibitors.
Our study confirms that patients with COVID-19 often have atypical STEMI presentations, including the frequent absence of a culprit coronary lesion. Our findings can help clinicians prepare for these atypical clinical presentations
- …