3,729 research outputs found
Operating characteristics of a hollow-cathode neutralizer for 5 and 8 centimeter-diameter electron bombardment mercury ion thrusters
Thin-tip 0.3-cm-outside-diameter hollow-cathode neutralizers were used to investigate causes of neutralizer tip erosion experienced in thruster endurance tests. Bell-jar tests indicated that neutralizers with new rolled tantalum foil inserts coated with an emissive mixture eroded very little over the neutral flow rates investigated (3 to 10 mA) for simulated 5- and 8-cm-diameter thruster neutralizer conditions. Tip erosion rates of neutralizers operated with no insert or emissive mixture increased by two orders of magnitude for both configurations as the neutral flow rate decreased. Spectroscopic analysis of the discharge plasma from neutralizers operated with inserts coated with the emissive mixture detected tungsten at all neutral flow rates for both thruster neutralizer conditions. The only source of tungsten was the tip. Therefore, detection of tungsten indicated neutralizer tip erosion. Barium, an element of the emissive mixture, was detected at low neutral flow rates for the 5-cm-diameter thruster neutralizer operating condition only
Texturing polymer surfaces by transfer casting
A technique for fabricating textured surfaces on polymers without altering their surface chemistries is described. A surface of a fluorocarbon polymer is exposed to a beam of ions to texture it. The polymer which is to be surface-roughened is then cast over the textured surface of the fluorocarbon polymer. After curing, the cast polymer is peeled off the textured fluorocarbon polymer, and the peeled off surface has negative replica of the textured surface. The microscopic surface texture provides large surface areas for adhesive bonding. In cardiovascular prosthesis applications the surfaces are relied on for the development of a thin adherent well nourished thrombus
Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys
An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing
Potential biomedical applications of ion beam technology
Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants
Direct thrust measurement of a 30-cm ion thruster
A direct thrust measurement of a 30-cm diameter ion thruster was accomplished by means of a laser interferometer thrust stand. The thruster was supported in a pendulum manner by three 3.65-m long wires. Electrical power was provided by means of 18 mercury filled pots. A movable 23-button planar probe rake was used to determine thrust loss due to ion beam divergence. Values of thrust, thrust loss due to ion beam divergence, and thrust loss due to multiple ionization were measured for ion beam currents ranging from 0.5 A to 2.5 A. Measured thrust values indicate an accuracy of approximately 1% and are in good agreement with thrust values calculated by indirect measurements
- …
