813 research outputs found

    Radiochemical separation of 7Be from the cooling water of the neutron spallation source SINQ at PSI

    Get PDF
    7Be is a key radionuclide for investigation of several astrophysical processes and phenomena. In addition, it is used as a tracer in wear measurements. It is produced in considerable amounts in the cooling water (D2O) of the Spallation Induced Neutron Source (SINQ) facility at PSI by spallation reactions on 16O with the generated fast neutrons. A shielded ion-exchange filter containing 100 mL of the mixed-bed ion exchanger LEWATIT was installed as a bypass for the cooling water into the cooling loop of SINQ for three months. The collected activity of 7Be was in the range of several hundred GBq. Further, the 7Be was separated and purified in a hot-cell remotely-controlled using a separation system installed. With the exception of 10Be, radioactive byproducts can be neglected, so that this cooling water could serve as an ideal source for highly active 7Be-samples. The facility is capable of producing 7Be with activities up to 1 TBq per year. The 7Be sample preparation is described in detail and the possible uses are discussed. In particular some preliminary results of 7Be ion beam production are presente

    Measurement of 1323 and 1487 keV resonances in 15N({\alpha}, {\gamma})19F with the recoil separator ERNA

    Get PDF
    The origin of fluorine is a widely debated issue. Nevertheless, the ^{15}N({\alpha},{\gamma})^{19}F reaction is a common feature among the various production channels so far proposed. Its reaction rate at relevant temperatures is determined by a number of narrow resonances together with the DC component and the tails of the two broad resonances at E_{c.m.} = 1323 and 1487 keV. Measurement through the direct detection of the 19F recoil ions with the European Recoil separator for Nuclear Astrophysics (ERNA) were performed. The reaction was initiated by a 15N beam impinging onto a 4He windowless gas target. The observed yield of the resonances at Ec.m. = 1323 and 1487 keV is used to determine their widths in the {\alpha} and {\gamma} channels. We show that a direct measurement of the cross section of the ^{15}N({\alpha},{\gamma})^{19}F reaction can be successfully obtained with the Recoil Separator ERNA, and the widths {\Gamma}_{\gamma} and {\Gamma}_{\alpha} of the two broad resonances have been determined. While a fair agreement is found with earlier determination of the widths of the 1487 keV resonance, a significant difference is found for the 1323 keV resonance {\Gamma}_{\alpha} . The revision of the widths of the two more relevant broad resonances in the 15N({\alpha},{\gamma})19F reaction presented in this work is the first step toward a more firm determination of the reaction rate. At present, the residual uncertainty at the temperatures of the ^{19}F stellar nucleosynthesis is dominated by the uncertainties affecting the Direct Capture component and the 364 keV narrow resonance, both so far investigated only through indirect experiments.Comment: 8 pages, 11 figures. Accepted for publication in PR

    TREATMENT OF CLASS I MALOCCLUSION WITH FRANKEL APPLIANCE

    Get PDF
    Aim. The aim of this paper is to evaluate the effect of the Frankel in child with class I malocclusion, maxillary and mandibular contraction, and anterior teeth crowding. Materials and methods. 5 patients with a class I division I malocclusion, maxillary and mandibular contraction and anterior crowding was enrolled in the present study. All patients presented with a stage CS2, CS3 or CS4. Patients with CS5 were not enrolled in the study. Before wearing the Frankel, on each patient head radiographs were taken in lateral plane with the head fixed in a cephalostat with a filmfocus distance of 4 m and a midsagittal-to-film distance of 0,1 m. Cephalometric analysis and casts analysis was performed before phase 1 treatment (T1), and immediately following phase 2 treatment (T2). In addition to standard cephalometric evaluation, another analysis, based on the distance of the basion, A and B to the T line, was done. Patients were instructed to wear the Frankel for 16 hours per day, during the night and afternoon, removing it only to eat and brush. Active treatment lasted 24 months for all patients. A statistical analysis of cephalometric and casts values before and after treatment was done.Results. After 24 months of treatment the cephalometric effects observed were: an increase of the anterior facial height (mean 3,8 mm), an increase of the distance of the basion to the T line (mean 3,6 mm), a incisors tip control (upper incisors mean 0°, lower incisors - 3,2°) and a sagittal maxillary growth control (the mean distance of A to T line was 0°, the mean distance of B to T line was of - 2,2 mm). On cast authors observed an expansion of the upper and lower arches (anterior upper arch expansion mean 2 mm, posterior upper arch expansion mean 2,5 mm; lower arch mean 1 mm) with anterior crowding resolution and incisors sagittal control. Conclusions. Authors evaluated that Frankel had a great repeal to control jaw growth, an increase of maxillary and mandibular expansion, an increase of the anterior facial height with a good control of incisors inclination

    Preparation and characterisation of isotopically enriched Ta2_2O5_5 targets for nuclear astrophysics studies

    Full text link
    The direct measurement of reaction cross sections at astrophysical energies often requires the use of solid targets of known thickness, isotopic composition, and stoichiometry that are able to withstand high beam currents for extended periods of time. Here, we report on the production and characterisation of isotopically enriched Ta2_2O5_5 targets for the study of proton-induced reactions at the Laboratory for Underground Nuclear Astrophysics facility of the Laboratori Nazionali del Gran Sasso. The targets were prepared by anodisation of tantalum backings in enriched water (up to 66% in 17^{17}O and up to 96% in 18^{18}O). Special care was devoted to minimising the presence of any contaminants that could induce unwanted background reactions with the beam in the energy region of astrophysical interest. Results from target characterisation measurements are reported, and the conclusions for proton capture measurements with these targets are drawn.Comment: accepted to EPJ

    Sloshing dynamics estimation for liquid-filled containers performing 3-dimensional motions: modeling and experimental validation

    Get PDF
    Many industrial applications require the displacement of liquid-filled containers on planar paths (namely, paths on a horizontal plane), by means of linear transport systems or serial robots. The movement of the liquid inside the container, known as sloshing, is usually undesired, thus there is the necessity to keep under control the peaks that the liquid free-surface exhibits during motion. This paper aims at validating a model for estimating the liquid sloshing height, taking into account 2-dimensional motions of a cylindrical container occurring on a horizontal plane, with accelerations up to 9.5 m/s2. This model can be exploited for assessment or optimization purposes. Experiments performed with a robot following three paths, each one of them with different motion profiles, are described. Comparisons between experimental results and model predictions are provided and discussed. Finally, the previous formulation is extended in order to take into account the addition of a vertical acceleration, up to 5 m/s2. The resulting 3-dimensional motions are experimentally validated to prove the effectiveness of the extended technique

    22Ne and 23Na ejecta from intermediate-mass stars: The impact of the new LUNA rate for 22Ne(p,gamma)23Na

    Get PDF
    We investigate the impact of the new LUNA rate for the nuclear reaction 22^{22}Ne(p,γ)23(p,\gamma)^{23}Na on the chemical ejecta of intermediate-mass stars, with particular focus on the thermally-pulsing asymptotic giant branch (TP-AGB) stars that experience hot-bottom burning. To this aim we use the PARSEC and COLIBRI codes to compute the complete evolution, from the pre-main sequence up to the termination of the TP-AGB phase, of a set of stellar models with initial masses in the range 3.0M6.0M3.0\,M_{\odot} - 6.0\,M_{\odot}, and metallicities Zi=0.0005Z_{\rm i}=0.0005, Zi=0.006Z_{\rm i}=0.006, and Zi=0.014Z_{\rm i} = 0.014. We find that the new LUNA measures have much reduced the nuclear uncertainties of the 22^{22}Ne and 23^{23}Na AGB ejecta, which drop from factors of 10\simeq 10 to only a factor of few for the lowest metallicity models. Relying on the most recent estimations for the destruction rate of 23^{23}Na, the uncertainties that still affect the 22^{22}Ne and 23^{23}Na AGB ejecta are mainly dominated by evolutionary aspects (efficiency of mass-loss, third dredge-up, convection). Finally, we discuss how the LUNA results impact on the hypothesis that invokes massive AGB stars as the main agents of the observed O-Na anti-correlation in Galactic globular clusters. We derive quantitative indications on the efficiencies of key physical processes (mass loss, third dredge-up, sodium destruction) in order to simultaneously reproduce both the Na-rich, O-poor extreme of the anti-correlation, and the observational constraints on the CNO abundance. Results for the corresponding chemical ejecta are made publicly available

    Loss of miR-204 expression is a key event in melanoma

    Get PDF
    Cutaneous melanoma (CM) is a malignancy with increasing occurrence. Its microRNA repertoire has been defined in a number studies, leading to candidates for biological and clinical relevance: miR-200a/b/c, miR-203, miR-205, miR-204, miR-211, miR-23b and miR-26a/b. Our work was aimed to validate the role of these candidate miRNAs in melanoma, using additional patients cohorts and in vitro cultures. miR-26a, miR-204 and miR-211 were more expressed in normal melanocytes, while miR-23b, miR-200b/c, miR-203 and miR-205 in epidermis and keratinocytes. None of the keratinocyte-related miRNAs was associated with any known mutation or with clinical covariates in melanoma. On the other hand, the loss of miR-204 was enriched in melanomas with NRAS sole mutation (Fisher exact test, P = 0.001, Log Odds = 1.67), and less frequent than expected in those harbouring CDKN2A mutations (Fisher exact test, P = 0.001, Log Odds − 1.09). Additionally, miR-204 was associated with better prognosis in two independent melanoma cohorts and its exogenous expression led to growth impairment in melanoma cell lines. Thus, miR-204 represents a relevant mechanism in melanoma, with potential prognostic value and its loss seems to act in the CDKN2A pathway, in cooperation with NRAS

    Labeling male anorectal malformations: objective evaluation of radiologic imaging before surgery

    Get PDF
    PurposeProne cross-table lateral x-ray (CTLxR) and colostogram aid surgical planning for anorectal malformations (ARMs) without perineal fistulas. We suggest objective imaging tools to classify ARMs.MethodsThree observers prospectively evaluated CTLxR and colostograms of male ARM patients (2012–2022) without perineal fistulas. The level of the rectal pouch was estimated with pubococcygeal (PC) and ischiatic (I) lines. On CTLxR, we described the “pigeon sign”, defined as the rectal pouch ending with a beak-like image, suspicious for a rectourinary fistula. ARM was defined as rectobulbar when the rectal pouch was below the I line, rectoprostatic when between PC and I lines, and rectovesical when above the PC line. Concordance was assessed with Fleiss' kappa. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the “pigeon sign” were calculated.ResultsThirteen patients were included in this study. The interobserver agreement on CTLxR was 69.2% (k = 0.54) on pouch ending, 84.6% (k = 0.69) on the “pigeon sign”, and 76.9% (k = 0.69) on diagnosis; concordance between observers and intraoperative diagnosis was 66.6% (k = 0.56). The “pigeon sign” had 75% sensitivity, 100% specificity, 100% PPV, and 50% NPV. The interobserver agreement on colostograms was 84.6% (k = 0.77) on pouch ending and 89.7% (k = 0.86) on diagnosis; concordance between observers and intraoperative diagnosis was 92.3% (k = 0.90).ConclusionPC and I lines and the “pigeon sign” are useful tools in examining CTLxR and colostograms. Adequate CTLxR interpretation may modify surgical strategy
    corecore