877 research outputs found
Power factor and your electrical utility bill in Egypt
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2003 IEEEBeside being a good neighbor and not causing harmonic voltage for others that are connected to your electrical distribution circuit, complying with the legal requirements of IEEE standards 519, and maintaining safe and economical operating environments for electrical equipment within your physical load, there is another very good reason to maintain a good power factor: saving money on your electrical utility bill. Utilities often encourage consumers to maintain a high PF by applying tariff clauses, which penalize consumers for low PF. This letter discusses the topic
LC compensators based on transmission loss minimization for nonlinear loads
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2004 IEEEThis paper presents a method employing the penalty function search algorithm to determine the LC compensator value for the optimal power factor correction in nonsinusoidal systems. The objective of the proposed method is to minimize the transmission loss while the power factor and efficiency are taken as constraints and utilized in order to solve the multiobjective optimization problem by transforming it into a single objective one. Examples show that the load nonlinearity can have a significant impact on optimal compensator sizes
The most economical power factor correction according to tariff structures in Egypt
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2005 IEEEA method of applying power-factor (PF) correction capacitors is discussed based on net savings maximization according to Egyptian's Tariff. Test results from examples taken from existing publications are presented. The purpose of this application technique is to utilize existing electrical distribution equipment in the installation of very large values of PF correction capacitors. It is concluded that LC compensators can be installed, thus providing maximum benefits from penalty elimination, system losses reduction, release of system transformer capacity, and minimum switching transients. Paybacks of less than one year can be expected
Practical considerations regarding power factor for nonlinear loads
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2004 IEEEThe choice of LC compensator may be constrained by the availability of manufacturers units. To account for this, the capacitor values are chosen from among standard values and for each value the transmission losses is minimized, or power factor is maximized, or transmission efficiency is maximized. The global minimum or maximum is obtained by scanning all local minims or maxims. The performance of the obtained compensator is discussed by means of numerical examples
LC compensators for power factor correction of nonlinear loads
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2004 IEEEA method is presented for finding the optimum fixed LC compensator for power factor correction of nonlinear loads where both source voltage and load current harmonics are present. The LC combination is selected because pure capacitive capacitors alone would not sufficiently correct the power factor. Optimization minimizes the transmission loss, maximizes the power factor, and maximizes the efficiency. The performance of the obtained compensator is discussed by means of numerical examples
Temperature effects on the electrical performance of large area multicrystalline silicon solar cells using the current shunt measuring technique
The temperature effects on the electrical performance of a large area multicrystalline silicon solar cell with back-contact technology have been studied in a desert area under ambient conditions using the current shunt measuring technique. Therefore, most of the problems encountered with traditional measuring techniques are avoided. The temperature dependency of the current shunt from 5ºC up to 50ºC has been investigated. Its temperature coefficient proves to be negligible which means that the temperature dependency of the solar cell is completely independent of the current shunt. The solar module installed in a tilted position at the optimum angle of the location, has been tested in two different seasons (winter and summer). The obtained solar cell short circuit current, open circuit voltage and output power are correlated with the measured incident radiation in both seasons and all results are discussed
An improved design of a fully automated multiple output micropotentiometer
This paper describes in details a new design of a fully automated multiple output micropotentiometer (?pot). A prototype has been built at the National Institute for Standards (NIS), Egypt to establish this highly improved AC voltage source in the millivolt range. The new device offers three different outputs covering a wide frequency range from only one outlet. This valuably supports the precise sourcing ranges of low AC voltage at NIS. The design and the operation theory of this prototype have been discussed in details. An automatic calibration technique has been introduced through specially designed software using the LabVIEW program to enhance the calibration technique and to reduce the uncertainty contributions. Relative small AC-DC differences of our prototype in the three output ranges are fairly verified. The expanded uncertainties of the calibration results for the three output ranges have been faithfully estimated. However, further work is needed to achieve the optimum performance of this new device
Electrical performance study of a large area multicrystalline silicon solar cell using a current shunt and a micropotentiometer
In this paper, a new technique using a Current Shunt and a Micropotentiometer has been used to study the electrical performance of a large area multicrystalline silicon solar cell at outdoor conditions. The electrical performance is mainly described by measuring both cell short circuit current and open circuit voltage. The measurements of this cell by using multimeters suffer from some problems because the cell has high current intensity with low output voltage. So, the solar cell short circuit current values are obtained by measuring the voltage developed across a known resistance Current Shunt. Samples of the obtained current values are accurately calibrated by using a Micropotentiometer (μpot) thermal element (TE) to validate this new measuring technique. Moreover, the solar cell open circuit voltage has been measured. Besides, the cell output power has been calculated and can be correlated with the measured incident radiation
Positive psychology of Malaysian students: impacts of engagement, motivation, self-compassion and wellbeing on mental health
Malaysia plays a key role in education of the Asia Pacific, expanding its scholarly output rapidly. However, mental health of Malaysian students is challenging, and their help-seeking is low because of stigma. This study explored the relationships between mental health and positive psychological constructs (academic engagement, motivation, self-compassion, and wellbeing), and evaluated the relative contribution of each positive psychological construct to mental health in Malaysian students. An opportunity sample of 153 students completed the measures regarding these constructs. Correlation, regression, and mediation analyses were conducted. Engagement, amotivation, self-compassion, and wellbeing were associated with, and predicted large variance in mental health. Self-compassion was the strongest independent predictor of mental health among all the positive psychological constructs. Findings can imply the strong links between mental health and positive psychology, especially selfcompassion. Moreover, intervention studies to examine the effects of self-compassion training on mental health of Malaysian students appear to be warranted.N/
Communicationless overcurrent relays coordination for active distribution network considering fault repairing periods
This paper presents an integrated overcurrent relays coordination approach for an Egyptian electric power distribution system. The protection scheme suits all network topologies, including adding distribution generation units (DGs) and creating new paths during fault repair periods.
The optimal types, sizes, and locations of DGs are obtained using HOMER software and genetic
algorithm (GA). The obtained values align with minimizing energy costs and environmental pollution. The proposed approach maintains dependability and security under all configurations using a single optimum setting for each relay. The calculations consider probable operating conditions, including DGs and fault repair periods. The enhanced coordination procedure partitions the ring into four parts and divides the process into four paths. The worst condition of two cascaded over current relays from the DGs' presence viewpoint is generalized for future work. Moreover, a novel concept addresses the issue of insensitivity during fault repair periods. The performance is validated through simulating an Egyptian primary distribution network
- …