9,900 research outputs found
Vibration-powered sensing system for engine condition monitoring
Condition monitoring is becoming an established technique for managing the maintenance of machinery in transport applications. Vibration energy harvesting allows wireless systems to be powered without batteries, but most traditional generators have been designed to operate at fixed frequencies. The variety of engine speeds (and hence vibration frequencies) in transport applications therefore means that these are not usable. This paper describes the application-driven specification, design and implementation of a novel vibration-powered sensing system for condition monitoring of engines. This demonstrates that, through careful holistic design of the entire system, condition monitoring systems can be powered solely from machine vibration, managing their energy resources and transmitting sensed data wirelessly
Ariel - Volume 10 Number 2
Executive Editors
Madalyn Schaefgen
David Reich
Business Manager
David Reich
News Editors
Medical College
Edward Zurad
CAHS
John Guardiani
World
Mark Zwanger
Features Editors
Meg Trexler
Jim O\u27Brien
Editorials Editor
Jeffrey Banyas
Photography and Sports Editor
Stuart Singer
Commons Editor
Brenda Peterso
Measurement of Corn Mechanical Damage Using Dielectric Properties
Dielectric measurements between 10 Hz to 13 MHz were obtained using an HP 4192A Impedance Analyzer for two types of artificially damaged corn samples: medium and severe damage. For each damage type, the measurements were obtained at two moisture content levels (11 and 19 percent, W.B.) and five damage levels (0, 10, 25, 50, and 100 percent). Each sample was also compressed to produce another bulk density. The results showed that dielectric properties were able to measure moisture content, bulk density, and mechanical damage level. Using dielectric variables only, medium damaged level was predicted with R 2 = 0.95 and RMSE =8.8 percent, while severe damage level was predicted with R 2 = 0.97 and RMSE = 6.96 percent. However, when the actual moisture content and bulk density were used along with dielectric variables, the severe damage level prediction was slightly improved with R 2 = 0.98 and RMSE = 5.97percent, and medium damage was also improved with R 2 = 0.98 and RMSE = 5.77 percent. The results showed that dielectric measurements had a good potential for measuring corn mechanical damage. However, further investigation is required to test combine- damaged corn using the same technique
Soliton-potential interaction in the nonlinear Klein-Gordon model
The interaction of solitons with external potentials in nonlinear
Klein-Gordon field theory is investigated using an improved model. The
presented model has been constructed with a better approximation for adding the
potential to the Lagrangian through the metric of background space-time. The
results of the model are compared with another model and the differences are
discussed.Comment: 14 pages,8 figure
Role of endoscopic ultrasound fine-needle aspiration evaluating adrenal gland enlargement or mass
AIM: To report the clinical impact of adrenal endoscopic ultrasound fine-needle aspiration (EUS-FNA) in the evaluation of patients with adrenal gland enlargement or mass.
METHODS: In a retrospective single-center case-series, patients undergoing EUS-FNA of either adrenal gland from 1997-2011 in our tertiary care center were included. Medical records were reviewed and results of EUS, cytology, adrenal size change on follow-up imaging ≥ 6 mo after EUS and any repeat EUS or surgery were abstracted. A lesion was considered benign if: (1) EUS-FNA cytology was benign and the lesion remained < 1 cm from its original size on follow-up computed tomography (CT), magnetic resonance imaging or repeat EUS ≥ 6 mo after EUS-FNA; or (2) subsequent adrenalectomy and surgical pathology was benign.
RESULTS: Ninety-four patients had left (n = 90) and/or right (n = 5) adrenal EUS-FNA without adverse events. EUS indications included: cancer staging or suspected recurrence (n = 31), pancreatic (n = 20), mediastinal (n = 10), adrenal (n = 7), lung (n = 7) mass or other indication (n = 19). Diagnoses after adrenal EUS-FNA included metastatic lung (n = 10), esophageal (n= 5), colon (n = 2), or other cancer (n = 8); benign primary adrenal mass or benign tissue (n = 60); or was non-diagnostic (n = 9). Available follow-up confirmed a benign lesion in 5/9 non-diagnostic aspirates and 32/60 benign aspirates. Four of the 60 benign aspirates were later confirmed as malignant by repeat biopsy, follow-up CT, or adrenalectomy. Adrenal EUS-FNA diagnosed metastatic cancer in 24, and ruled out metastasis in 10 patients. For the diagnosis of malignancy, EUS-FNA of either adrenal had sensitivity, specificity, positive predictive value and negative predictive value of 86%, 97%, 96% and 89%, respectively.
CONCLUSION: Adrenal gland EUS-FNA is safe, minimally invasive and a sensitive technique with significant impact in the management of adrenal gland mass or enlargement
Source partitioning using stable isotopes: coping with too much variation.
Final published version of the article deposited in accordance with SHERPA RoMEO guidelinesStable isotope analysis is increasingly being utilised across broad areas of ecology and biology. Key to much of this work is the use of mixing models to estimate the proportion of sources contributing to a mixture such as in diet estimation
Landowner willingness to engage in long-term timber leases in West Virginia, USA
As global competition increases for wood-based products, the need for more efficient supply chains becomes increasingly important. In the forest products sector, these supply chains involve individuals and firms ranging from private forestland owners with standing timber to factories producing final finished products. Under the assumption that ‘transparent’ supply chains are beneficial to members within the supply chain, the authors are investigating how this transparency can be increased and what benefits might accrue to private forest owners who are associated with a specific supply chain under a long-term agreement. In recent years, hunting lease agreements between family forest owners and various organized hunt clubs or individuals have become commonplace in the Appalachian mountains of West Virginia. Can long-term timber leases become a new opportunity for landowners, forestry professionals, and wood-based industries? This paper describes a survey of private forestland owners in West Virginia that investigated the perceived concerns, benefits and barriers landowners have with regard to entering long-term timber leases with forestry professionals and timber firms
Management of Branch‐duct Intraductal Papillary Mucinous Neoplasms: A Large Single Center Study to Assess Predictors of Malignancy and Long Term Outcomes
Background and Aims
Management of branch-duct intraductal papillary mucinous neoplasms (BD-IPMNs) remains challenging. We determined factors associated with malignancy in BD-IPMNs and long-term outcomes.
Methods
This retrospective cohort study included all patients with established BD-IPMNs by the International Consensus Guidelines (ICG) 2012 and/or pathologically confirmed BD-IPMNs in a tertiary care referral center between 2001 and 2013. Main outcome measures were the association between high-risk stigmata (HRS)/worrisome features (WFs) of the ICG 2012 and malignant BD-IPMNs, performance characteristics of EUS-FNA for the diagnosis of malignant BD-IPMNs, and recurrence and long-term outcomes of BD-IPMN patients undergoing surgery or imaging surveillance.
Results
Of 364 BD-IPMN patients, 229 underwent imaging surveillance and 135 underwent surgery. Among the 135 resected BD-IPMNs, HRS/WFs on CT/magnetic resonance imaging (MRI) were similar between the benign and malignant groups, but main pancreatic duct (MPD) dilation (5-9 mm) was more frequently identified in malignant lesions. On EUS-FNA, mural nodules, MPD features suspicious for involvement, and suspicious/positive malignant cytology were more frequently detected in the malignant group with a sensitivity, specificity, and accuracy of 33%, 94%, and 86%; 42%, 91%, and 83%; and 33% 91%, and 82%, respectively. Mural nodules identified by EUS were missed by CT/MRI in 28% in the malignant group. Patients with malignant lesions had a higher risk of any IPMN recurrence during a mean follow-up period of 131 months (P = .01).
Conclusions
Among HRS and WFs of the ICG 2012, an MPD size of 5 to 9 mm on CT/MRI was associated with malignant BD-IPMNs. EUS features including mural nodules, MPD features suspicious for involvement, and suspicious/malignant cytology were accurate and highly specific for malignant BD-IPMNs. Our study highlights the incremental value of EUS-FNA over imaging in identifying malignant BD-IPMNs, particularly in patients without WFs and those with smaller cysts. Benign IPMN recurrence was observed in some patients up to 8 years after resection
- …
