2,057 research outputs found
Linac modeling for external beam radiotherapy quality assurance using a dedicated 2D pixelated detector
International audienceQuality assurance is a key issue in intensity modulated radiotherapy. Errors can occur in the dose delivery process induces significant differences between the planned treatment and the delivered one. In this context, the Medical Application Physics group of the LPSC is developing TraDeRa (Transparent Detector for Radiotherapy), a 2D pixelated matrix of ionization chambers located upstream to the patient. The signal map obtained with TraDeRa has to be processed to provide medical observables to quantify the quality of the treatment delivery. This relies on accurate Monte Carlo simulations benchmarked with measurements performed under a linear accelerator (Linac).The work described in this paper lies in the optimization of the Linac head simulation and the development of an innovative Monte Carlo/measurements comparison method to perform an accurate enough model of the X-ray production device. An optimized parametrization of the particles transport allowed an increase of the simulation efficiency by a factor 3. The characteristics of an electron beam of a reference Linac were matched with the simulation results by using dose deposition of the created X-ray beam in a water tank. Two parameters are particularly critical: the nominal energy of the electrons and the radial distribution of impact on the target. The innovative method was able to provide within minutes those two parameters for any Linac, achieving, for example, a 10 keV precision on the energy determination for a 6 MV operating Linac
Expert consensus document: Semantics in active surveillance for men with localized prostate cancer — results of a modified Delphi consensus procedure
Active surveillance (AS) is broadly described as a management option for men with low-risk prostate cancer, but semantic heterogeneity exists in both the literature and in guidelines. To address this issue, a panel of leading prostate cancer specialists in the field of AS participated in a consensus-forming project using a modified Delphi method to reach international consensus on definitions of terms related to this management option. An iterative three-round sequence of online questionnaires designed to address 61 individual items was completed by each panel member. Consensus was considered to be reached if ≥70% of the experts agreed on a definition. To facilitate a common understanding among all experts involved and resolve potential ambiguities, a face-to-face consensus meeting was held between Delphi survey rounds two and three. Convenience sampling was used to construct the panel of experts. In total, 12 experts from Australia, France, Finland, Italy, the Netherlands, Japan, the UK, Canada and the USA participated. By the end of the Delphi process, formal consensus was achieved for 100% (n = 61) of the terms and a glossary was then developed. Agreement between international experts has been reached on relevant terms and subsequent definitions regarding AS for patients with localized prostate cancer. This standard terminology could support multidisciplinary communication, reduce the extent of variations in clinical practice and optimize clinical decision making
Measurement of the W boson mass
We present a measurement of the W boson mass in W -> ev decays using 1 fb^-1
of data collected with the D0 detector during Run II of the Fermilab Tevatron
collider. With a sample of 499830 W -> ev candidate events, we measure M_W =
80.401 +- 0.043 GeV. This is the most precise measurement from a single
experiment.Comment: As published in PR
Measurement of the electron charge asymmetry in ppbar->W+X->enu+X events at sqrt{s}=1.96 TeV
We present a measurement of the electron charge asymmetry in
ppbar->W+X->enu+X events at a center of mass energy of 1.96 TeV using 0.75 fb-1
of data collected with the D0 detector at the Fermilab Tevatron Collider. The
asymmetry is measured as a function of the electron transverse momentum and
pseudorapidity in the interval (-3.2, 3.2) and is compared with expectations
from next-to-leading order calculations in perturbative quantum chromodynamics.
These measurements will allow more accurate determinations of the proton parton
distribution functions.Comment: 7 pages, 3 figures, Fermilab-Pub-08/249-E, submitted to Phys. Rev.
Let
A search for the standard model Higgs boson in the missing energy and acoplanar b-jet topology at sqrt(s) = 1.96 TeV
We report a search for the standard model Higgs boson in the missing energy
and acoplanar b-jet topology, using an integrated luminosity of 0.93 inverse
femtobarn recorded by the D0 detector at the Fermilab Tevatron Collider. The
analysis includes signal contributions from pp->ZH->nu nu b b, as well as from
WH production in which the charged lepton from the W boson decay is undetected.
Neural networks are used to separate signal from background. In the absence of
a signal, we set limits on the cross section of pp->VH times the branching
ratio of H->bb at the 95% C.L. of 2.6 - 2.3 pb, for Higgs boson masses in the
range 105 - 135 GeV, where V=W,Z. The corresponding expected limits range from
2.8 pb - 2.0 pb.Comment: Submitted to Phys. Rev. Letter
Observation of ZZ production in ppbar collisions at sqrt(s) = 1.96 TeV
We present an observation for ZZ -> l+l-l'+l'- (l, l' = e or mu) production
in ppbar collisions at a center-of-mass energy of sqrt(s) = 1.96 TeV. Using 1.7
fb-1 of data collected by the D0 experiment at the Fermilab Tevatron Collider,
we observe three candidate events with an expected background of 0.14 +0.03
-0.02 events. The significance of this observation is 5.3 standard deviations.
The combination of D0 results in this channel, as well as in ZZ -> l+l-nunubar,
yields a significance of 5.7 standard deviations and a combined cross section
of sigma(ZZ) = 1.60 +/- 0.63 (stat.) +0.16 -0.17 (syst.) pb.Comment: 7 pages, 1 figure, 2 tables Modified slightly following review
proces
b-Jet Identification in the D0 Experiment
Algorithms distinguishing jets originating from b quarks from other jet
flavors are important tools in the physics program of the D0 experiment at the
Fermilab Tevatron p-pbar collider. This article describes the methods that have
been used to identify b-quark jets, exploiting in particular the long lifetimes
of b-flavored hadrons, and the calibration of the performance of these
algorithms based on collider data.Comment: submitted to Nuclear Instruments and Methods in Physics Research
Measurement of the lifetime of the B_c meson in the semileptonic decay channel
Using approximately 1.3 fb-1 of data collected by the D0 detector between
2002 and 2006, we measure the lifetime of the B_c meson in the B_c -> J/psi mu
nu X final state. A simultaneous unbinned likelihood fit to the J/\psi+mu
invariant mass and lifetime distributions yields a signal of 881 +/- 80 (stat)
candidates and a lifetime measurement of \tau(B_c) = 0.448 +0.038 -0.036 (stat)
+/- 0.032 (syst) ps.Comment: 7 pages, 2 figures, submitted to Phys. Rev. Let
Search for new fermions ("quirks") at the Fermilab Tevatron Collider
We report results of a search for particles with anomalously high ionization
in events with a high transverse energy jet and large missing transverse energy
in fb of integrated luminosity collected by the D0 experiment at
the Fermilab Tevatron collider. Production of such particles
(quirks) is expected in scenarios with extra QCD-like {\it SU(N)} sectors, and
this study is the first dedicated search for such signatures. We find no
evidence of a signal and set a lower mass limit of 107 ~GeV for the mass of a
charged quirk with strong dynamics scale in the range from 10 keV to
1 MeV.Comment: submitted to Phys. Rev. Letter
Measurement of the t-channel single top quark production cross section
The D0 collaboration reports direct evidence for electroweak production of
single top quarks through the t-channel exchange of a virtual W boson. This is
the first analysis to isolate an individual single top quark production
channel. We select events containing an isolated electron or muon, missing
transverse energy, and two, three or four jets from 2.3 fb^-1 of ppbar
collisions at the Fermilab Tevatron Collider. One or two of the jets are
identified as containing a b hadron. We combine three multivariate techniques
optimized for the t-channel process to measure the t- and s-channel cross
sections simultaneously. We measure cross sections of 3.14 +0.94 -0.80 pb for
the t-channel and 1.05 +-0.81 pb for the s-channel. The measured t-channel
result is found to have a significance of 4.8 standard deviations and is
consistent with the standard model prediction.Comment: 7 pages, 6 figure
- …