1,328 research outputs found
Characterization of Shewanella oneidensis MtrC: a cell-surface decaheme cytochrome involved in respiratory electron transport to extracellular electron acceptors
MtrC is a decaheme c-type cytochrome associated with the outer cell membrane of Fe(III)-respiring species of the Shewanella genus. It is proposed to play a role in anaerobic respiration by mediating electron transfer to extracellular mineral oxides that can serve as terminal electron acceptors. The present work presents the first spectropotentiometric and voltammetric characterization of MtrC, using protein purified from Shewanella oneidensis MR-1. Potentiometric titrations, monitored by UV–vis absorption and electron paramagnetic resonance (EPR) spectroscopy, reveal that the hemes within MtrC titrate over a broad potential range spanning between approximately +100 and approximately -500 mV (vs. the standard hydrogen electrode). Across this potential window the UV–vis absorption spectra are characteristic of low-spin c-type hemes and the EPR spectra reveal broad, complex features that suggest the presence of magnetically spin-coupled low-spin c-hemes. Non-catalytic protein film voltammetry of MtrC demonstrates reversible electrochemistry over a potential window similar to that disclosed spectroscopically. The voltammetry also allows definition of kinetic properties of MtrC in direct electron exchange with a solid electrode surface and during reduction of a model Fe(III) substrate. Taken together, the data provide quantitative information on the potential domain in which MtrC can operate
Observations of bedforms on a dissipative macrotidal beach
NERC NE/H004262/1 and NE/H02543X/1 DRIB
Multifrequency Strategies for the Identification of Gamma-Ray Sources
More than half the sources in the Third EGRET (3EG) catalog have no firmly
established counterparts at other wavelengths and are unidentified. Some of
these unidentified sources have remained a mystery since the first surveys of
the gamma-ray sky with the COS-B satellite. The unidentified sources generally
have large error circles, and finding counterparts has often been a challenging
job. A multiwavelength approach, using X-ray, optical, and radio data, is often
needed to understand the nature of these sources. This chapter reviews the
technique of identification of EGRET sources using multiwavelength studies of
the gamma-ray fields.Comment: 35 pages, 22 figures. Chapter prepared for the book "Cosmic Gamma-ray
Sources", edited by K.S. Cheng and G.E. Romero, to be published by Kluwer
Academic Press, 2004. For complete article and higher resolution figures, go
to: http://www.astro.columbia.edu/~muk/mukherjee_multiwave.pd
Search for direct pair production of the top squark in all-hadronic final states in proton-proton collisions at s√=8 TeV with the ATLAS detector
The results of a search for direct pair production of the scalar partner to the top quark using an integrated luminosity of 20.1fb−1 of proton–proton collision data at √s = 8 TeV recorded with the ATLAS detector at the LHC are reported. The top squark is assumed to decay via t˜→tχ˜01 or t˜→ bχ˜±1 →bW(∗)χ˜01 , where χ˜01 (χ˜±1 ) denotes the lightest neutralino (chargino) in supersymmetric models. The search targets a fully-hadronic final state in events with four or more jets and large missing transverse momentum. No significant excess over the Standard Model background prediction is observed, and exclusion limits are reported in terms of the top squark and neutralino masses and as a function of the branching fraction of t˜ → tχ˜01 . For a branching fraction of 100%, top squark masses in the range 270–645 GeV are excluded for χ˜01 masses below 30 GeV. For a branching fraction of 50% to either t˜ → tχ˜01 or t˜ → bχ˜±1 , and assuming the χ˜±1 mass to be twice the χ˜01 mass, top squark masses in the range 250–550 GeV are excluded for χ˜01 masses below 60 GeV
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
Hepatocellular carcinoma in Pakistan: where do we stand?
Context:
From the 1970s till the mid 1990s, hepatitis B was the most common etiological factor for hepatocellular carcinoma (HCC) in Pakistan. Afterwards, a shift in HCC etiology was observed with a steady rise in hepatitis C virus (HCV) related HCC cases. HCV-3a, which is the most prevalent genotype, is also most frequent in HCV related HCC. There was an increase in the proportion of non-B non-C (NBNC) HCC cases as well, which might be attributed to an increase in non-alcoholic fatty liver disease.
Evidence Acquisition:
The age-standardized rate for HCC is 7.64/100 000 in males and 2.8/100 000 in females. Male to female ratio is 3.6:1. Usual age of presentation is in the fifth and sixth decade. Most patients present with advanced disease, as they are not in a regular surveillance program. This is more so for patients with NBNC chronic liver disease. As many sonologists in Pakistan are practicing without sufficient training to pick up early lesions, alpha-fetoprotein is still recommended to compliment ultrasound in the surveillance of HCC.
Results:
Majority of HCC patients present with nonresectable disease. Interventions such as transarterial chemoembolization, radiofrequency ablation, resection and chemotherapy including sorafenib are available in selected centers. Pakistan appears to be in an area of intermediate endemicity for HCC. There is a need for population based epidemiological studies to estimate the exact disease burden.
Conclusions:
Measures to prevent the spread of hepatitis C and B can slow down the epidemic rise in the incidence of HCC in the coming decades. There is a need to implement a proper surveillance program to identify HCC cases at an early stage
Improving the delivery and efficiency of fungus-impregnated cloths for control of adult Aedes aegypti using a synthetic attractive lure
Abstract Background Entomopathogenic fungi are highly promising agents for controlling Aedes aegypti mosquitoes. Deploying fungus-impregnated black cloths in PET traps efficiently reduced Ae. aegypti female survival rates under intra-domicile conditions. With the aim of further increasing the effectiveness of the traps, the addition of attractive lures to fungus-impregnated traps was evaluated. Methods Black cloths were suspended inside 2 l plastic bottles called “PET traps”. These traps were placed in rooms simulating human residences. The first experiments evaluated the attraction of mosquitoes to PET traps with black cloths covered in adhesive film with and without synthetic lures (AtrAedes™). Traps were left in the test rooms for either 24 or 48 h. The attractiveness of the lures over time was also evaluated. The efficiency of PET traps with fungus-impregnated black cloths associated with lures was compared to that of traps without lures. Results The highest percentage of captured mosquitoes (31 and 66%) were observed in PET traps with black cloths covered in adhesive film + attractive lure maintained in test rooms for 24 h and 48 h, respectively. Black cloths covered in adhesive film captured 17 or 36% of the mosquitoes at 24 h and 48 h, respectively. The attractiveness of the lures fell gradually over time, capturing 37% after 5 days on the bench and 22% of the mosquitoes after 30 days exposure to ambient conditions. Associating attractive synthetic lures with black cloths impregnated with M. anisopliae placed in test rooms for 120 h reduced mean survival to 32%, whilst black cloths impregnated with M. anisopliae without lures resulted in a 48% survival rate. Using Beauveria bassiana in the traps resulted in a 52% reduction in mosquito survival, whilst combining Beauveria and AtrAedes resulted in a 36% survival rate. PET traps impregnated with fungus + AtrAedes resulted in similar reductions in survival when left in the rooms for 24, 48, 72 or 120 h. Conclusions AtrAedes increased attractiveness of PET traps with black cloths under intra-domicile conditions and when associated with M. anisopliae or B. bassiana, significantly reduced Aedes survival. This strategy will reduce the number of PET traps necessary per household
Factors affecting glomerular filtration rate, as measured by iohexol disappearance, in men with or at risk for HIV infection
Objective: Formulae used to estimate glomerular filtration rate (GFR) underestimate higher GFRs and have not been well-studied in HIV-infected (HIV(+)) people; we evaluated the relationships of HIV infection and known or potential risk factors for kidney disease with directly measured GFR and the presence of chronic kidney disease (CKD). Design: Cross-sectional measurement of iohexol-based GFR (iGFR) in HIV(+) men (n = 455) receiving antiretroviral therapy, and HIV-uninfected (HIV(-)) men (n = 258) in the Multicenter AIDS Cohort Study. Methods: iGFR was calculated from disappearance of infused iohexol from plasma. Determinants of GFR and the presence of CKD were compared using iGFR and GFR estimated by the CKD-Epi equation (eGFR). Results: Median iGFR was higher among HIV(+) than HIV(-) men (109 vs. 106 ml/min/1.73 m2, respectively, p = .046), and was 7 ml/min higher than median eGFR. Mean iGFR was lower in men who were older, had chronic hepatitis C virus (HCV) infection, or had a history of AIDS. Low iGFR (≤90 ml/min/1.73 m2) was associated with these factors and with black race. Other than age, factors associated with low iGFR were not observed with low eGFR. CKD was more common in HIV(+) than HIV(-) men; predictors of CKD were similar using iGFR and eGFR. Conclusions: iGFR was higher than eGFR in this population of HIV-infected and -uninfected men who have sex with men. Presence of CKD was predicted equally well by iGFR and eGFR, but associations of chronic HCV infection and history of clinically-defined AIDS with mildly decreased GFR were seen only with iGFR. © 2014 Margolick et al
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
- …
