406 research outputs found

    Quantifying Cortical Bone Free Water Using short echo time (STE-MRI) at 1.5T

    Get PDF
    Purpose: The purpose of our study was to use Dual-TR STE-MR protocol as a clinical tool for cortical bone free water quantification at 1.5T and validate it by comparing the obtained results (MR-derived results) with dehydration results. Methods: Human studies were compliant with HIPPA and were approved by the institutional review board. Short Echo Time (STE) MR imaging with different Repetition Times (TRs) was used for quantification of cortical bone free water T1 (T1free) and concentration (\r{ho}free). The proposed strategy was compared with the dehydration technique in seven bovine cortical bone samples. The agreement between the two methods was quantified by using Bland and Altman analysis. Then we applied the technique on a cross-sectional population of thirty healthy volunteers (18F/12M) and examined the association of the biomarkers with age. Results: The mean values of \r{ho}free for bovine cortical bone specimens were quantified as 4.37% and 5.34% by using STE-MR and dehydration techniques, respectively. The Bland and Altman analysis showed good agreement between the two methods along with the suggestion of 0.99% bias between them. Strong correlations were also reported between \r{ho}free (r2 = 0.62) and T1free and age (r2 = 0.8). The reproducibility of the method, evaluated in eight subjects, yielded an intra-class correlation of 0.95. Conclusion: STE-MR imaging with dual-TR strategy is a clinical solution for quantifying cortical bone \r{ho}free and T1free

    Measurement of Nonlinear Optical Responses of Ag Thin Films

    Get PDF
    In this paper we report the preparation of silver nanoparticle thin films by cylindrical direct current reactive magnetron sputtering (at 10-5 torr initial pressure) and characterization of their nonlinear optical properties. BK7 glasses were selected as substrate. Nonlinear optical response of silver nanoparticle thin films was measured by moiré deflectometry technique using 15 mW He-Ne laser illuminations. All fabricated silver nanoparticle thin films were evaluated using atomic force microscopy and spectrophotometry (from visible region to near infrared region)

    Studying the Recent Improvements in Holograms for Three-Dimensional Display

    Get PDF
    Displayers tend to become three-dimensional. The most advantage of holographic 3D displays is the possibility to observe 3D images without using glasses. The quality of created images by this method has surprised everyone. In this paper, the experimental steps of making a transmission hologram have been mentioned. In what follows, current advances of this science-art will be discussed. The aim of this paper is to study the recent improvements in creating three-dimensional images and videos by means of holographic techniques. In the last section we discuss the potentials of holography to be applied in future

    A Study on Advances in Creating 3D Holographic Images and Optical Applications of Holography

    Get PDF
    Nowadays, the most beautiful 3D pictures and movies are created by means of holograms. The most advantage of this technique is the possibility to observe 3D images without using glasses. The quality of created images by this method has surprised everyone. In this paper, the experimental steps of making a transmission hologram have been mentioned. In what follows, current advances of this science–art will be discussed. In another section of this paper the optical application of holography has been reviewed. Finally, the predictions for the future of holography have also been studied

    Assessing cortical bone mechanical properties using collagen proton fraction from ultrashort echo time magnetization transfer (UTE-MT) MRI modeling.

    Get PDF
    Cortical bone shows as a signal void when using conventional clinical magnetic resonance imaging (MRI). Ultrashort echo time MRI (UTE-MRI) can acquire high signal from cortical bone, thus enabling quantitative assessments. Magnetization transfer (MT) imaging combined with UTE-MRI can indirectly assess protons in the organic matrix of bone. This study aimed to examine UTE-MT MRI techniques to estimate the mechanical properties of cortical bone. A total of 156 rectangular human cortical bone strips were harvested from the tibial and femoral midshafts of 43 donors (62 ± 22 years old, 62 specimens from females, 94 specimens from males). Bone specimens were scanned using UTE-MT sequences on a clinical 3 T MRI scanner and on a micro-computed tomography (μCT) scanner. A series of MT pulse saturation powers (400°, 600°, 800°) and frequency offsets (2, 5, 10, 20, 50 kHz) was used to measure the macromolecular fraction (MMF) utilizing a two-pool MT model. Failure mechanical properties of the bone specimens were measured using 4-point bending tests. MMF from MRI results showed significant strong correlations with cortical bone porosity (R = -0.72, P < 0.01) and bone mineral density (BMD) (R = +0.71, P < 0.01). MMF demonstrated significant moderate correlations with Young modulus, yield stress, and ultimate stress (R = 0.60-0.61, P < 0.01). These results suggest that the two-pool UTE-MT model focusing on the organic matrix of bone can potentially serve as a novel tool to detect the variations of bone mechanical properties and intracortical porosity

    Hemorrhagic Colloid Cyst Presenting with Acute Hydrocephaly

    Get PDF
    Colloid cysts are benign slow-growing cystic lesions located on the roof of the third ventricle that usually present with symptoms related to gradual rise of intracranial pressure. They mostly remain asymptomatic and sometimes grow progressively and cause diverse symptoms associated with increased intracranial pressure such as headache, diplopia, and sixth cranial nerve palsy. Here we report a 47-year-old female who presented to the emergency department with acute severe headache and nausea/vomiting. On MRI examination acute hydrocephaly due to hemorrhagic colloid cyst was detected. Acute hemorrhage in colloid cysts is extremely rare and may present with symptoms of acute increase in the intracranial pressure. Intracystic hemorrhage is very rarely reported as a complication of colloid cyst presenting with paroxysmal symptoms of acute hydrocephaly

    Quantifying cortical bone free water using short echo time (STE-MRI) at 1.5 T

    Get PDF
    Purpose: The purpose of our study was to use Dual-TR STE-MR protocol as a clinical tool for cortical bone free water quantification at 1.5 T and validate it by comparing the obtained results (MR-derived results) with dehydration results. Methods: Human studies were compliant with HIPPA and were approved by the institutional review board. Short Echo Time (STE) MR imaging with different Repetition Times (TRs) was used for quantification of cortical bone free water T1 (T1free) and concentration (�free). The proposed strategy was compared with the dehydration technique in seven bovine cortical bone samples. The agreement between the two methods was quantified by using Bland and Altman analysis. Then we applied the technique on a cross-sectional population of thirty healthy volunteers (18F/12M) and examined the association of the biomarkers with age. Results: The mean values of �free for bovine cortical bone specimens were quantified as 4.37 and 5.34 by using STE-MR and dehydration techniques, respectively. The Bland and Altman analysis showed good agreement between the two methods along with the suggestion of 0.99 bias between them. Strong correlations were also reported between �free (r2 = 0.62) and T1free and age (r2 = 0.8). The reproducibility of the method, evaluated in eight subjects, yielded an intra-class correlation of 0.95. Conclusion: STE-MR imaging with dual-TR strategy is a clinical solution for quantifying cortical bone �free and T1free. © 2020 Elsevier Inc

    Designing and Validation of Consumers’ anxiety Management Pattern During the Economic Sanction on Iran

    Get PDF
    One of the most influential aspects of the economic embargo is the psychological dimension, which has negative effects on the economic structure of society. The aim of this study was to design and validate an anxiety management model in consumer behavior during the economic embargo on Iran. The approach of this research is deductive-inductive and from the perspective of the purpose of a fundamental research that has been mixed with the research method and based on empirical philosophy. The community of research participants in the model presentation section included theoretical experts (university professors) and experimental experts (executives and industry and business owners), 20 of whom were selected using purposive sampling in the ISM section. have became. The statistical population of the quantitative section including consumers of capital goods and samples in this section were estimated 384 people using Cochran's formula and were selected by Two-stage sampling method. Data collection tools were library studies and the use of a researcher-made questionnaire. In the qualitative part of the research, the meta-combined method has been used and the initial model has been designed with the ISM method and finally validated with the partial least squares method

    Myopic regression after photorefractive keratectomy: a retrospective cohort study

    Get PDF
    Background: Myopic regression is a major complication of photorefractive keratectomy (PRK). The rates and causes vary considerably among different studies. This study aimed to investigate myopic regression at six months after myopic PRK. Methods: In this retrospective cohort study, we included all eligible patients with myopia ranging from - 0.75 to - 9 D, aged 18 to 50 years, who underwent PRK by a single surgeon with the availability of preoperative and postoperative data at six months after the initial procedure. All participants underwent comprehensive ophthalmic examinations preoperatively and at six months post-PRK. Overcorrection was planned based on the participant’s age range to achieve the desired refractive result after PRK. All patients received the same postoperative antibiotic and steroid eye drops in a similar dosage regimen, and the contact lenses were removed after complete corneal epithelial healing. Based on the spherical equivalent of refraction six months after PRK, eyes without and with myopic regression were allocated into groups 1 and 2, respectively. Results: We included 254 eyes of 132 patients who underwent myopic PRK with a mean (standard deviation) age of 30.12 (7.48) years; 82 (62.12%) were women and 50 (37.88%) were men. The frequency of myopic regression was significantly lower in patients with younger age, lower preoperative cylindrical refraction, and lower ablation depth (all P < 0.05). Overcorrection was more successful in eyes with low myopia than in eyes with high myopia (P < 0.05). The highest frequency of myopic regression occurred in eyes with moderate myopia (25.68%), followed by eyes with high myopia (20.0%) and low myopia (6.54%). Among different age groups, patients aged less than or equal to 30 years had a lower frequency of myopic regression. The frequency of myopic regression in the different age groups was 5.0% at 18-20 years, 7.46% at 26-30 years, 12.28% at 21-25 years, 21.31% at 31-35 years, and 26.53% at 36-50 years. Conclusions: Overcorrection was more successful in eyes with low myopia than in eyes with high myopia. The success rate was higher in younger patients with lower astigmatism and ablation depths. Myopic regression was most frequent in eyes with moderate myopia, followed by those with high and low myopia. Further studies should replicate our findings over a longer follow-up period with a larger sample size before generalization is warranted
    corecore