485 research outputs found
Shear bond strength between veneering ceramics and ceria-stabilized zirconia/alumina
STATEMENT OF PROBLEM: Ceria-stabilized tetragonal ZrO(2)/Al(2)O(3) nanocomposite (Ce-TZP/A) offers superior properties compared to yttria-stabilized zirconia (Y-TZP). However, the bond quality to veneering ceramics has not been investigated. PURPOSE: The purpose of this study was to evaluate the bond strength of different veneering ceramics to Ce-TZP/A. MATERIAL AND METHODS: Cubes of Ce-TZP/A (NANOZR) (edge length, 10 mm) were layered with veneering ceramics (5 mm in thickness) with or without application of a liner and sheared at the interface. The effect of different surface treatments (polished with 3-mum diamond paste or airborne-particle abraded) was evaluated with 1 veneering ceramic (Cerabien ZR). Shear bond strength of 5 additional veneering ceramics (IPS e.max, Initial ZR, Triceram, Vintage ZR, or VITA VM 9) to polished Ce-TZP/A was measured (n=10). Polished Y-TZP (Hint-ELs ZrO(2) HIP) veneered with 2 ceramics (Cerabien ZR, Vintage ZR) served as the control. Mean shear bond strength values (MPa) were calculated. The means were statistically analyzed with 2-way ANOVA for the effect of surface treatment and liner, 2-way ANOVA for the effect of different veneering ceramic brands and liner, and 3-way ANOVA for the effect of substrate, veneering ceramic brands, and liner, as well as 1-way ANOVA for the differences between the veneering ceramics. A post hoc Scheffé test was used (alpha=.05). RESULTS: The effects of surface treatment (P=.007) or application of liner (P<.001) were significant. Shear bond strength with different veneering ceramics showed bond strength values with means ranging between 14.2 +/-1.7 MPa (IPS e.max with liner) and 27.5 +/-4.2 MPa (VITA VM 9). A significant difference was found between the results of shear bond tests with Y-TZP and Ce-TZP/A (P=.022). The application of a liner on Y-TZP had no significant effect. CONCLUSIONS: Airborne-particle abrasion is not necessary to enhance the shear bond strength of the evaluated veneering ceramics to Ce-TZP/A. Liners impair the shear bond strength of veneering ceramics to Ce-TZP/A
Clinical performance and failures of zirconia-based fixed partial dentures: a review literature
Human Treated Dentin Matrix Hydrogel as a Drug Delivery Scaffold for Regenerative Endodontics
Introduction: The objective of the current study was to develop a human treated dentin matrix (hTDM) hydrogel for use as a scaffold to allow the controlled release of an antimicrobial agent for regenerative endodontics. Materials and Methods: Human extracted teeth were treated via chemical demineralization using ethylene diamine tetra-acetic acid solution to produce hTDM powder. Fourier transform infrared spectroscopy (FTIR) was conducted to determine the functional groups of hTDM, scanning electron microscopy (SEM) was used to define the morphology/particle size of hTDM, and energy dispersive X-ray analysis was performed to identify the superficial apatite groups. Prepared hTDM powder was added to the amoxicillin-clavulanate mixture with a mass ratio of 1:1. Then, the combination was dripped into a 5% (w/v) calcium chloride solution. Antibiotic release profiles were evaluated for 14 days via high performance liquid chromatography (HPLC). Hydrogel degradation properties were studied for 14 days using 10 mL of phosphate buffered saline (PBS). Encapsulation efficiency was determined by HPLC, while minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of amoxicillin-clavulanate were determined against Enterococcus faecalis (E. faecalis). The antibacterial activity of amoxicillin-clavulanate against E. faecalis was investigated for 14 days via agar diffusion test. Statistical analysis was performed with the Shapiro-Wilk test (P=0.05). Results: hTDM showed statistically a significant difference for percentage weight change (P=0.1). The encapsulation efficiencies for hTDM hydrogel with antibiotic and hydrogel with antibiotic was 96.08%±0.02 and 94.62%±0.11, respectively. MIC and MBC values of amoxicillin-clavulanate against E. faecalis were 2.4 µg/mL and 9.6 µg/mL, respectively. The antibacterial activity of antibiotic loaded hTDM hydrogels was significantly greater than loaded hydrogels alone by 31% after 4 and 100% at 14 days, respectively (P≤0.001). Conclusions: This in vitro study showed antibiotic-loaded injectable hTDM hydrogel could be an alternative system to transfer antibiotic-based intracanal medicaments for use in regenerative endodontics
Influence of cement thickness on resin-zirconia microtensile bond strength
PURPOSE: The aim of this study was to evaluate the influence of resin cement thickness on the microtensile bond strength between zirconium-oxide ceramic and resin cement.
MATERIALS AND METHODS: Thirty-two freshly extracted molars were transversely sectioned at the deep dentin level and bonded to air-abraded zirconium oxide ceramic disks. The specimens were divided into 8 groups based on the experimental conditions (cement type: Rely X UniCem or Panavia F 2.0, cement thickness: 40 or 160 µm, storage: thermocycled or not). They were cut into microbeams and stored in 37℃ distilled water for 24 h. Microbeams of non-thermocycled specimens were submitted to a microtensile test, whereas those of thermocycled groups were thermally cycled for 18,000 times immediately before the microtensile test. Three-way ANOVA and Sheffe's post hoc tests were used for statistical analysis (α=95%).
RESULTS: All failures occurred at the resin-zirconia interface. Thermocycled groups showed lower microtensile bond strength than non-thermocycled groups (P.05). The number of adhesive failures increased after thermocycling in all experimental conditions. No cohesive failure was observed in any experimental group.
CONCLUSION: When resin cements of adhesive monomers are applied over air-abraded zirconia restorations, the degree of fit does not influence the resin-zirconia microtensile bond strength.ope
Influence of Material Properties on Rate of Resorption of Two Bone Graft Materials after Sinus Lift Using Radiographic Assessment
Purpose. The aim of this study was to investigate the influence of chemical and physical properties of two graft materials on the rate of resorption. Materials and Methods. Direct sinus graft procedure was performed on 22 patients intended for implant placement. Two types of graft materials were used (Bio-Oss and Cerabone) and after 8 months healing time the implants were inserted. Radiographic assessment was performed over the period of four years. Particle size, rate of calcium release, and size and type of crystal structure of each graft were evaluated. Results. The average particle size of Bio-Oss (1 mm) was much smaller compared to Cerabone (2.7 mm). The amount of calcium release due to dissolution of material in water was much higher for Bio-oss compared to Cerabone. X-ray image analysis revealed that Bio-Oss demonstrated significantly higher volumetric loss (33.4 ± 3.1%) of initial graft size compared to Cerabone (23.4 ± 3.6%). The greatest amount of vertical loss of graft material volume was observed after one year of surgery. Conclusion. The chemical and physical properties of bone graft material significantly influence resorption rate of bone graft materials used for sinus augmentation
Evaluation of shear bond strengths of gingiva-colored composite resin to porcelain, metal and zirconia substrates
Influence of Material Properties on Rate of Resorption of Two Bone Graft Materials after Sinus Lift Using Radiographic Assessment
. Purpose. The aim of this study was to investigate the influence of chemical and physical properties of two graft materials on the rate of resorption. Materials and Methods. Direct sinus graft procedure was performed on 22 patients intended for implant placement. Two types of graft materials were used (Bio-Oss and Cerabone) and after 8 months healing time the implants were inserted. Radiographic assessment was performed over the period of four years. Particle size, rate of calcium release, and size and type of crystal structure of each graft were evaluated. Results. The average particle size of Bio-Oss (1 mm) was much smaller compared to Cerabone (2.7 mm). The amount of calcium release due to dissolution of material in water was much higher for Bio-oss compared to Cerabone. X-ray image analysis revealed that Bio-Oss demonstrated significantly higher volumetric loss (33.4 ± 3.1%) of initial graft size compared to Cerabone (23.4 ± 3.6%). The greatest amount of vertical loss of graft material volume was observed after one year of surgery. Conclusion. The chemical and physical properties of bone graft material significantly influence resorption rate of bone graft materials used for sinus augmentation
Improving adhesion between luting cement and zirconia-based ceramic with an alternative surface treatment
This study evaluated the influence of an alternative surface treatment on the microshear bond strength (μsbs) of zirconia-based ceramic. Thirty-five zirconia disks were assigned to five groups according to the following treatments: Control (CO), glass and silane were not applied to the zirconia surface; G1, air blasted with 100μm glass beads + glaze + silane; G2, a gel containing 15% (by weight) glass beads applied to the ceramic surface + glaze + silane; G3, a gel containing 25% (by weight) glass beads applied to the ceramic surface + glaze + silane; and G4, a gel containing 50% (by weight) glass beads applied to the ceramic surface + glaze + silane. The specimens were built up using RelyX ARC®, according to the manufacturer’s recommendations, and inserted in an elastomeric mold with an inner diameter of 0.8 mm. The μsbs test was performed using a testing machine at a crosshead speed of 0.5 mm/min. ANOVA and Tukey’s test (p < 0.05) were applied to the bond strength values (in MPa). CO (15.6 ± 4.1) showed the lowest μsbs value. There were no statistical differences between the G1 (24.9 ± 7.4), G2 (24.9 ± 2.3), G3 (35.0 ± 10.3) and G4 (35.3 ± 6.0) experimental groups. Those groups submitted to surface treatments with higher concentrations of glass showed a lower frequency of adhesive failures. In conclusion, the glass application improved the interaction between the ceramic and the luting cement
The Effect of Heat Treatment and Feldspathic Glazing on Some Mechanical Properties of Zirconia
- …
