16 research outputs found

    Mechanical Behavior of Ceramic Monolithic Systems With Different Thicknesses

    Full text link
    SUMMARYObjectives:This study assessed the fully stabilized zirconia (FSZ) Prettau Anterior, the partially stabilized zirconia (PSZ) Prettau, and the lithium disilicate IPS e.max CAD (LD) through microstructural and mechanical characterization and effect of thickness on fracture load of the ceramics.Methods and Materials:Disk-shaped specimens (12 mm diameter and 1.2 mm thickness) were prepared for biaxial flexural strength (BFS) and Weibull statistics (n=30). For the fracture load static test (FLST) and Weibull statistics (n=30), disk-shaped specimens 12 mm in diameter and thicknesses of 0.5 mm, 1 mm, and 1.5 mm were cemented on an epoxy-resin substrate.Results:BFS (MPa) results were PSZ: 683.0 ± 70.23; FSZ: 438.6 ± 64.1; and LD: 248.6 ± 37.3. One-way analysis of variance (ANOVA) for BFS was significant (p&amp;lt;0.001), and the Tukey post hoc test showed differences among all ceramics. There was difference in characteristic strength, but there was no difference in Weibull modulus. Two-way ANOVA for FLST was significant for ceramic (p&amp;lt;0001), thickness (p&amp;lt;0001), and interaction (p&amp;lt;0001). There was no difference among all ceramics at the 0.5 mm thickness. PSZ had higher values for the 1.0 mm and 1.5 mm thicknesses. LD of 1.5 mm thickness exhibited a higher FLST than FSZ.Conclusions:PSZ had the highest BFS, but when cemented on a substrate, all ceramics with 0.5 mm thickness behaved similarly. Despite the lower BFS, LD had a fracture load similar or superior to FSZ when cemented on a substrate.</jats:sec

    Effect of cyclic compressive loading on the bond strength of an adhesive system to dentin after collagen removal

    No full text
    Purpose: The objective of this study was to verify the effect of cyclic compressive loading on the shear bond strength of an adhesive system following Collagen removal. Materials and Methods: Sixty bovine teeth were divided into 4 groups based on the adhesive procedure used: groups 1 and 2 - etching with 35% phosphoric acid and application of the Single Bond adhesive system; groups 3 and 4 - after etching, a 10% sodium hypochlorite solution was applied for 1 min before the application of the adhesive. in all the specimens, a Z100 resin cylinder was built up over the bond area. Groups 2 and 4 were submitted to 500,000 cycles with a load of 100 N. Results: The mean values for the shear bond test (MPa) were: group 1: 7.37 +/- 1.15; group 2: 5.72 +/- 1.66; group 3: 5.95 +/- 1.21; group 4: 3.66 +/- 1.12. There was no difference between groups 1 and 2 (p > 0.01). Between groups 1 and 3, 2 and 4, and 3 and 4 there was a significant difference (p < 0.01). The majority of the specimens demonstrated an adhesive failure. Conclusion: The application of sodium hypochlorite on dentin decreased the values of shear bond strength, as did the load cycling in the group treated with sodium hypochlorite.7212713

    Air Abrasion Before and/or After Zirconia Sintering: Surface Characterization, Flexural Strength, and Resin Cement Bond Strength

    Full text link
    SUMMARY The purpose of this in vitro study was to evaluate the effect of air-abrasion/zirconia sintering order on the yttria partially stabilized tetragonal zirconia polycrystal (Y-TZP) surface characterization (roughness, morphology, and phase transformation), flexural strength (FS), and shear bond strength (SBS) to a resin cement. Y-TZP specimens were air abraded with 50-μm Al2O3 particles after (AS), before (BS), or before and after zirconia sintering (BAS). For roughness (Ra), 30 block specimens (12×12×3.0 mm; n=10) had their surfaces analyzed by a profilometer. Next, on the air-abraded surfaces of these specimens, composite resin discs (n=30) were bonded with RelyX ARC. The bonded specimens were stored for 24 hours in distilled water at 37°C before shear testing. Failure mode was determined with a stereomicroscope (20×). The surface morphology (n=2) was evaluated by SEM (500×). For the four-point flexural strength test (EMIC DL2000), 39 bar-shaped specimens (20×4.0×1.2 mm; n=13) were air abraded according to the three conditions proposed, and an additional group (nonabraded) was evaluated (n=13). The quantitative analysis of phase transformation (n=1) was completed with Rietveld refinement with X-ray diffraction data. Ra (μm) and SBS (MPa) data were analyzed by one-way analysis of variance (ANOVA) and the Tukey test (α=0.05). Pearson correlation analysis was used to determine if there was a correlation between roughness and SBS. For FS (MPa) data, one-way ANOVA and the Dunnett C-test (α=0.05) were used. The air-abrasion/zirconia sintering order influenced significantly (p&amp;lt;0.001) Ra, SBS, and FS. The BS and AS groups presented the highest (1.3 μm) and the lowest (0.7 μm) Ra. The highest SBS (7.0 MPa) was exhibited by the BAS group, followed by the AS group (5.4 MPa) and finally by the BS group (2.6 MPa). All groups presented 100% adhesive failure. A weak correlation (r=−0.45, p&amp;lt;0.05) was found between roughness and SBS. The air-abrasion/zirconia sintering order provided differences in the surface morphology. The nonabraded (926.8 MPa) and BS (816.3 MPa) groups exhibited statistically similar FS values but lower values than the AS (1249.1 MPa) and BAS (1181.4 MPa) groups, with no significant difference between them. The nonabraded, AS, BS, and BAS groups exhibited, respectively, percentages of monoclinic phase of 0.0 wt%, 12.2 wt%, 0.0 wt%, and 8.6 wt%. The rougher surface provided by the air-abrasion before zirconia sintering may have impaired the bonding with the resin cement. The morphological patterns were consistent with the surface roughness. Considering the short-term SBS and FS, the BAS group exhibited the best performance. Air abrasion, regardless of its performance order, provides tetragonal to monoclinic transformation, while sintering tends to zero the monoclinic phase content.</jats:p

    Polymerization Shrinkage and Flexural Modulus of Flowable Dental Composites

    No full text
    Linear polymerization shrinkage (LPS), flexural strength (FS) and modulus of elasticity (ME) of low-viscosity resin composites (Admira Flow&trade;, Grandio Flow&trade;/VOCO; Filtek Z350 Flow&trade;/3M ESPE; Tetric Flow&trade;/Ivoclar-Vivadent) was evaluated using a well-established conventional micro-hybrid composite as a standard (Filtek Z250&trade;/3M ESPE). For the measurement of LPS, composites were applied to a cylindrical metallic mould and polymerized (n = 8). The gap formed at the resin/mould interface was observed using SEM (1500×). For FS and ME, specimens were prepared according to the ISO 4049 specifications (n = 10). Statistical analysis of the data was performed with one-way ANOVA and the Tukey test. The conventional resin presented significantly lower LPS associated with high FS and ME, but only the ME values of the conventional resin differed significantly from the low-viscosity composites. The relationship between ME and LPS of low-viscosity resin composites when used as restorative material is a critical factor in contraction stress relief and marginal leakage

    Flexural and diametral tensile strength of composite resins

    Get PDF
    This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined
    corecore