2,942 research outputs found
A probability-conserving cross-section biasing mechanism for variance reduction in Monte Carlo particle transport calculations
In Monte Carlo particle transport codes, it is often important to adjust
reaction cross sections to reduce the variance of calculations of relatively
rare events, in a technique known as non-analogous Monte Carlo. We present the
theory and sample code for a Geant4 process which allows the cross section of a
G4VDiscreteProcess to be scaled, while adjusting track weights so as to
mitigate the effects of altered primary beam depletion induced by the cross
section change. This makes it possible to increase the cross section of nuclear
reactions by factors exceeding 10^4 (in appropriate cases), without distorting
the results of energy deposition calculations or coincidence rates. The
procedure is also valid for bias factors less than unity, which is useful, for
example, in problems that involve computation of particle penetration deep into
a target, such as occurs in atmospheric showers or in shielding
A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode
In this work we attempt to establish the best time resolution attainable with
a scintillation counter consisting of a plastic scintillator read out by a
Geiger-mode Avalanche Photodiode. The measured time resolution is inversely
proportional to the square root of the energy deposited in the scintillator,
and scales to 18ps (sigma) at 1MeV. This result competes with the best ones
reported for photomultiplier tubes.Comment: 8 pages, 8 figure
Flux creep in Bi2Sr2Ca1Cu2O(8+x) single crystals
Dissipative effects were investigated in Bi2Sr2Ca1Cu2O(8+x) single crystals by critical current and magnetic relaxation measurements. Activation energies for the flux motion were determined from the temperature dependence of the critical current and from the time decay of the zero field cooled and the remanent magnetization. The effective activation energy was found to increase with temperature, in agreement with the existence of a distribution of activation energies (E sub o 20 meV at 4.2 K for H + 10 kOe applied parallel to the c-axis.)
The development of juvenile stages of Xiphinema index (Nematoda : Dorylaimida) on Vitis vinifera
Protein kinase CK2 is widely expressed in follicular, Burkitt and diffuse large B-cell lymphomas and propels malignant B-cell growth.
Serine-threonine kinase CK2 is highly expressed and pivotal for survival and proliferation in multiple myeloma, chronic lymphocytic leukemia and mantle cell lymphoma. Here, we investigated the expression of \u3b1 catalytic and \u3b2 regulatory CK2 subunits by immunohistochemistry in 57 follicular (FL), 18 Burkitt (BL), 52 diffuse large B-cell (DLBCL) non-Hodgkin lymphomas (NHL) and in normal reactive follicles. In silico evaluation of available Gene Expression Profile (GEP) data sets from patients and Western blot (WB) analysis in NHL cell-lines were also performed. Moreover, the novel, clinical-grade, ATP-competitive CK2-inhibitor CX-4945 (Silmitasertib) was assayed on lymphoma cells. CK2 was detected in 98.4% of cases with a trend towards a stronger CK2\u3b1 immunostain in BL compared to FL and DLBCL. No significant differences were observed between Germinal Center B (GCB) and non-GCB DLBCL types. GEP data and WB confirmed elevated CK2 mRNA and protein levels as well as active phosphorylation of specific targets in NHL cells. CX-4945 caused a dose-dependent growth-arresting effect on GCB, non-GCB DLBCL and BL cell-lines and it efficiently shut off phosphorylation of NF-\u3baB RelA and CDC37 on CK2 target sites. Thus, CK2 is highly expressed and could represent a suitable therapeutic target in BL, FL and DLBCL NHL
A new design for the CERN-Fr\'ejus neutrino Super Beam
We present an optimization of the hadron focusing system for a low-energy
high-intensity conventional neutrino beam (Super-Beam) proposed on the basis of
the HP-SPL at CERN with a beam power of 4 MW and an energy of 4.5 GeV. The far
detector would be a 440 kton Water Cherenkov detector (MEMPHYS) located at a
baseline of 130 km in the Fr\'ejus site. The neutrino fluxes simulation relies
on a new GEANT4 based simulation coupled with an optimization algorithm based
on the maximization of the sensitivity limit on the mixing angle.
A new configuration adopting a multiple horn system with solid targets is
proposed which improves the sensitivity to and the CP violating
phase .Comment: 11 pages, 18 figures, 2 table
Flux creep in Bi2Sr2CaCu2O8(sub +x) single crystals
The results of a magnetic study on a Bi2Sr2CaCu2O(8+x) single crystal are reported. Low field susceptibility (dc and ac), magnetization cycles and time dependent measurements were performed. With increasing the temperature the irreversible regime of the magnetization cycles is rapidly restricted to low fields, showing that the critical current J(sub c) becomes strongly field dependent well below T(sub c). At 2.4 K the critical current in zero field, determined from the remanent magnetization by using the Bean formula for the critical state, is J(sub c) = 2 10(exp 5) A/sq cm. The temperature dependence of J(sub c) is satisfactorily described by the phenomenological law J(sub c) = J(sub c) (0) (1 - T/T(sub c) (sup n), with n = 8. The time decay of the zero field cooled magnetization and of the remanent magnetization was studied at different temperatures for different magnetic fields. The time decay was found to be logarithmic in both cases, at least at low temperatures. At T = 4.2 K for a field of 10 kOe applied parallel to the c axis, the average pinning energy, determined by using the flux creep model, is U(sub o) = 0.010 eV
The politics of alcohol policy in Nigeria: a critical analysis of how and why brewers use strategic ambiguity to supplant policy initiatives
The global call by the World Health Assembly (WHA) to control the rising alcohol-related problems caused by harmful consumption through policy became necessary in 2005 due to the recognition of the fact that many countries did not have alcohol policies. This gave rise to the adoption of a ten-point policy strategy by the World Health Organization (WHO) Member States in 2010. Against this backdrop, many countries adopted alcohol policies to reduce harmful alcohol consumption. Nigeria was one of the WHO Member Countries that adopted the resolution. Nigeria is among the 30 countries with the highest per capita consumption and alcohol-related problems, yet has not formulated alcohol policy to date. This paper draws on Eisenberg’s Strategic Ambiguity Model to explore the role of brewers in supplanting alcohol policy initiatives in Nigeria. It argues that the leading alcohol producers in Nigeria have been the main reason alcohol policies have not been formulated. The article focuses on why their campaigns for responsible drinking, promotions, sponsorships and ‘strategic social responsibilities’ may have increased since the WHA made the call and the WHO adopted the resolution in 2010. It concludes by arguing that there is an urgent need to formulate policies drawing from the WHO resolution to curtail the activities of these brewers and reduce harmful consumption
An Algorithm for Computing Screened Coulomb Scattering in Geant4
An algorithm has been developed for the Geant4 Monte-Carlo package for the
efficient computation of screened Coulomb interatomic scattering. It explicitly
integrates the classical equations of motion for scattering events, resulting
in precise tracking of both the projectile and the recoil target nucleus. The
algorithm permits the user to plug in an arbitrary screening function, such as
Lens-Jensen screening, which is good for backscattering calculations, or
Ziegler-Biersack-Littmark screening, which is good for nuclear straggling and
implantation problems. This will allow many of the applications of the TRIM and
SRIM codes to be extended into the much more general Geant4 framework where
nuclear and other effects can be included.Comment: 19 pages, 6 figures; corrected to rerferee comments, typo in equation
5 fixe
Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
The scintillation efficiency of liquid xenon for nuclear recoils has been
measured to be nearly constant in the recoil energy range from 140 keV down to
5 keV. The average ratio of the efficiency for recoils to that for gamma-rays
is found to be 0.19+-0.02.Comment: 13 pages, 5 figure
- …
