2,176 research outputs found
Breaking a Chaotic Cryptographic Scheme Based on Composition Maps
Recently, a chaotic cryptographic scheme based on composition maps was
proposed. This paper studies the security of the scheme and reports the
following findings: 1) the scheme can be broken by a differential attack with
chosen-plaintext, where is the size of
plaintext and is the number of different elements in plain-text; 2) the
scheme is not sensitive to the changes of plaintext; 3) the two composition
maps do not work well as a secure and efficient random number source.Comment: 9 pages, 7 figure
Diagnostic values of serum levels of pepsinogens and gastrin-17 for screening gastritis and gastric cancer in a high risk area in Northern Iran
Background: Gastric cancer (GC) is the second cause of cancer related death in the world. It may develop by progression from its precancerous condition, called gastric atrophy (GA) due to gastritis. The aim of this study was to evaluate the accuracy of serum levels of pepsinogens (Pg) and gastrin-17 (G17) as non-invasive methods to discriminate GA or GC (GA/GC) patients. Materials and Methods: Subjects referred to gastrointestinal clinics of Golestan province of Iran during 2010 and 2011 were invited to participate. Serum levels of PgI, PgII and G17 were measured using a GastroPanel kit. Based on the pathological examination of endoscopic biopsy samples, subjects were classified into four groups: normal, non-atrophic gastritis, GA, and GC. Receiver operating curve (ROC) analysis was used to determine cut-off values. Indices of validity were calculated for serum markers. Results: Study groups were normal individuals (n=74), non-atrophic gastritis (n=90), GA (n=31) and GC patients (n=30). The best cut-off points for PgI, PgI/II ratio, G17 and HP were 80 μg/L, 10, 6 pmol/L, and 20 EIU, respectively. PgI could differentiate GA/GC with high accuracy (AUC=0.83; 95%CI: 0.76-0.89). The accuracy of a combination of PgI and PgI/II ratio for detecting GA/GC was also relatively high (AUC=0.78; 95%CI: 0.70-0.86). Conclusions: Our findings suggested PgI alone as well as a combination of PgI and PgI/II ratio are valid markers to differentiate GA/GC. Therefore, Pgs may be considered in conducting GC screening programs in high-risk areas
Pulsating flow and convective heat transfer in a cavity with inlet and outlet sections
This paper deals with the study of 2-D, laminar, pulsating flow inside a heated rectangular cavity with different aspect ratios. The cooling liquid (water with temperature dependent viscosity and thermal conductivity) comes and leaves the cavity via inlet and outlet ports. The flow topology is characterised by the large recirculation regions that exist at inner corners of the cavity. These low velocity regions cause the heat transfer to be small when compared, for instance, to that of a straight channel. We study the effect that a prescribed pulsation at the inlet port has on the cavity heat transfer. This pulsating boundary condition, of the unsteady Poiseuille type, is described by its frequency and the amplitude of the pressure gradient. The time averaged Reynolds number of the flow, based on the hydraulic diameter of the inlet channel, is 100 and we consider that the dimensionless pulsation frequency (Strouhal number) varies in the range from 0.0 to 0.4. We show that the prescribed pulsation enhances heat transfer in the cavity and that the mechanism that causes this enhancement appears to be the periodic change in the recirculation flow pattern generated by the pulsation. Regarding the quantitative extent of heat transfer recovery, we find that appropriate selection of the pulsation parameters allows for the cavity to behave like a straight channel that is the configuration with the highest Nusselt number
Excitonic enhancement of nonradiative energy transfer to bulk silicon with the hybridization of cascaded quantum dots
Cataloged from PDF version of article.We report enhanced sensitization of silicon through nonradiative energy transfer (NRET) of the excitons in an energy-gradient structure composed of a cascaded bilayer of green-and red-emitting CdTe quantum dots (QDs) on bulk silicon. Here NRET dynamics were systematically investigated comparatively for the cascaded energy-gradient and mono-dispersed QD structures at room temperature. We show experimentally that NRET from the QD layer into silicon is enhanced by 40% in the case of an energy-gradient cascaded structure as compared to the mono-dispersed structures, which is in agreement with the theoretical analysis based on the excited state population-depopulation dynamics of the QDs. (C) 2013 AIP Publishing LLC
Junctionless 6T SRAM cell
The design of a 6T SRAM cell with 20 nm junctionless (JL) MOSFETs is reported. It is shown that a 6T SRAM cell designed with JL MOSFETs achieves a high static noise margin (SNM) of 185 mV, retention noise or hold margin (RNM) of 381 mV and writability current (IWR) of 33 µA along with a low leakage current (ILEAK) of 2 pA at a supply voltage (VDD) of 0.9 V for cell and pull-up ratios of 1. Results offer a new opportunity to design future SRAM cells with nanoscale JL MOSFETs.<br/
Controlling surface statistical properties using bias voltage: Atomic force microscopy and stochastic analysis
The effect of bias voltages on the statistical properties of rough surfaces
has been studied using atomic force microscopy technique and its stochastic
analysis. We have characterized the complexity of the height fluctuation of a
rough surface by the stochastic parameters such as roughness exponent, level
crossing, and drift and diffusion coefficients as a function of the applied
bias voltage. It is shown that these statistical as well as microstructural
parameters can also explain the macroscopic property of a surface. Furthermore,
the tip convolution effect on the stochastic parameters has been examined.Comment: 8 pages, 11 figures
Applications of tripled chaotic maps in cryptography
Security of information has become a major issue during the last decades. New
algorithms based on chaotic maps were suggested for protection of different
types of multimedia data, especially digital images and videos in this period.
However, many of them fundamentally were flawed by a lack of robustness and
security. For getting higher security and higher complexity, in the current
paper, we introduce a new kind of symmetric key block cipher algorithm that is
based on \emph{tripled chaotic maps}. In this algorithm, the utilization of two
coupling parameters, as well as the increased complexity of the cryptosystem,
make a contribution to the development of cryptosystem with higher security. In
order to increase the security of the proposed algorithm, the size of key space
and the computational complexity of the coupling parameters should be increased
as well. Both the theoretical and experimental results state that the proposed
algorithm has many capabilities such as acceptable speed and complexity in the
algorithm due to the existence of two coupling parameter and high security.
Note that the ciphertext has a flat distribution and has the same size as the
plaintext. Therefore, it is suitable for practical use in secure
communications.Comment: 21 pages, 10 figure
Risk of prostate cancer after isolated high-grade prostatic intraepithelial neoplasia (HGPIN) detected on extended core needle biopsy : a UK hospital experience.
Background High-grade prostatic intraepithelial neoplasia (HGPIN) is a precursor lesion to prostate cancer (CaP). UK-based studies examining the occurrence of isolated HGPIN and subsequent risk of CaP are lacking. Our aim was to assess the occurrence of HGPIN in a regional UK population and to determine whether in a retrievable cohort of such patients that had repeat extended core biopsies, there was an elevated risk of CaP. Methods A retrospective analysis of the pathology database was conducted at our institution (Lancashire Teaching Hospitals NHS Foundation Trust) for prostate biopsies recorded between January 2001 and December 2005 (all extended core biopsies). Those patients with isolated HGPIN on 1st set of biopsies were identified and, their clinical characteristics and pathological findings from subsequent biopsies (if any) were determined. The risk of CaP on subsequent biopsies based on presenting baseline PSA was stratified. Results Of 2,192 biopsied patients, there were 88 cases of isolated HGPIN of which 67 patients underwent one or more repeat biopsies. In this repeat-biopsy group, 28 CaP diagnoses were made. Age at first biopsy (P 20 ng/ml – 87.5%. Conclusion Based on our results, we recommend delaying the 1st repeat biopsy at low PSA range but to have a shorter interval to repeat biopsies at intermediate and higher PSA ranges
Laminar heat transfer enhancement downstream of a backward facing step by using a pulsating flow
This study is motivated by the need to devise means to enhance heat transfer in configurations, like the back step, that appear in certain types of MEMS that involve fluid flow and that are not very efficient from the thermal transfer point of view. In particular, the work described in this paper studies the effect that a prescribed flow pulsation (defined by two control parameters: velocity pulsation frequency and pressure gradient amplitude at the inlet section) has on the heat transfer rate behind a backward facing step in the unsteady laminar 2-D regime. The working fluid that we have considered is water with temperature dependent viscosity and thermal conductivity. We have found that, for inlet pressure gradients that avoid flow reversal at both the upstream and downstream boundary conditions, the timeaveraged Nusselt number behind the step depends on the two above mentioned control parameters and is always larger than in the steady-state case. At Reynolds 100 and pulsating at the resonance frequency, the maximum time-averaged Nusselt number in the horizontal wall region located behind the step whose length is four times the step height is 55% larger than in the steady-case. Away from the resonant pulsation frequency, the time-averaged Nusselt number smoothly decreases and approaches its steady-state value
- …
