192 research outputs found

    Research of the Additional Losses Occurring in Optical Fiber at its Multiple Bends in the Range Waves 1310nm, 1550nm and 1625nm Long

    Get PDF
    Article is devoted to research of the additional losses occurring in the optical fiber at its multiple bends in the range waves of 1310 nanometers, 1550 nanometers and 1625 nanometers long. Article is directed on creation of the external factors methods which allow to estimate and eliminate negative influence. The automated way of calculation of losses at a bend is developed. Results of scientific researches are used by engineers of "Kazaktelekom" AS for practical definition of losses service conditions. For modeling the Wolfram|Alpha environment - the knowledge base and a set of computing algorithms was chosen. The greatest losses are noted on wavelength 1310nm and 1625nm. All dependences are nonlinear. Losses with each following excess are multiplicative

    Broad, broader, broadest

    Get PDF

    Algoritmos de Detecçao de Taquicardias Incorporado a Desfibriladores Automáticos Implantáveis. 1) Desfibriladores Monocamerais

    Get PDF
    Diversos algoritmos foram incorporados aos cardioversores-desfibriladores automáticos implantáveis (CDIs) para identificar os distúrbios do ritmo ventricular e, sobretudo, para os diferenciar de taquicardias supraventriculares que nao necessitam terapia. Esses benefícios também sao encontrados nos CDIs bicamerais que têm como benefício a detecçao atrial acoplada à detecçao do ventrículo. O objetivo dos algoritmos é de identificar todas as arritmias ventriculares (sensibilidade de 100%), para que sejam tratadas corretamente. Devem ainda evitar erros de identificaçao de arritmias supraventriculares (especificidade máxima). Infelizmente, nao é possível alcançar 100% de sensibilidade e especificidade. Além disso, todo aumento da especificidade será acompanhado por uma diminuiçao da sensibilidade. Essa diminuiçao de especificidade pode conduzir a falha na detecçao dos distúrbios do ritmo ventricular, e como conseqüência, isto é pior que o tratamento inadequado de uma taquicardia sinusal ou supraventricular

    Algoritmos de Detecçao de Taquicardias Incorporado a Desfibriladores Automáticos Implantáveis. 1) Desfibriladores Monocamerais

    Get PDF
    Diversos algoritmos foram incorporados aos cardioversores-desfibriladores automáticos implantáveis (CDIs) para identificar os distúrbios do ritmo ventricular e, sobretudo, para os diferenciar de taquicardias supraventriculares que nao necessitam terapia. Esses benefícios também sao encontrados nos CDIs bicamerais que têm como benefício a detecçao atrial acoplada à detecçao do ventrículo. O objetivo dos algoritmos é de identificar todas as arritmias ventriculares (sensibilidade de 100%), para que sejam tratadas corretamente. Devem ainda evitar erros de identificaçao de arritmias supraventriculares (especificidade máxima). Infelizmente, nao é possível alcançar 100% de sensibilidade e especificidade. Além disso, todo aumento da especificidade será acompanhado por uma diminuiçao da sensibilidade. Essa diminuiçao de especificidade pode conduzir a falha na detecçao dos distúrbios do ritmo ventricular, e como conseqüência, isto é pior que o tratamento inadequado de uma taquicardia sinusal ou supraventricular

    Effect of Systemic Hypertension With Versus Without Left Ventricular Hypertrophy on the Progression of Atrial Fibrillation (from the Euro Heart Survey).

    Get PDF
    Hypertension is a risk factor for both progression of atrial fibrillation (AF) and development of AF-related complications, that is major adverse cardiac and cerebrovascular events (MACCE). It is unknown whether left ventricular hypertrophy (LVH) as a consequence of hypertension is also a risk factor for both these end points. We aimed to assess this in low-risk AF patients, also assessing gender-related differences. We included 799 patients from the Euro Heart Survey with nonvalvular AF and a baseline echocardiogram. Patients with and without hypertension were included. End points after 1 year were occurrence of AF progression, that is paroxysmal AF becoming persistent and/or permanent AF, and MACCE. Echocardiographic LVH was present in 33% of 379 hypertensive patients. AF progression after 1 year occurred in 10.2% of 373 patients with rhythm follow-up. In hypertensive patients with LVH, AF progression occurred more frequently as compared with hypertensive patients without LVH (23.3% vs 8.8%, p = 0.011). In hypertensive AF patients, LVH was the most important multivariably adjusted determinant of AF progression on multivariable logistic regression (odds ratio 4.84, 95% confidence interval 1.70 to 13.78, p = 0.003). This effect was only seen in male patients (27.5% vs 5.8%, p = 0.002), while in female hypertensive patients, no differences were found in AF progression rates regarding the presence or absence of LVH (15.2% vs 15.0%, p = 0.999). No differences were seen in MACCE for hypertensive patients with and without LVH. In conclusion, in men with hypertension, LVH is associated with AF progression. This association seems to be absent in hypertensive women
    corecore