54,866 research outputs found
Automated software quality visualisation using fuzzy logic techniques
In the past decade there has been a concerted effort by the software industry to improve the quality of its products. This has led to the inception of various techniques with which to control and measure the process involved in software development. Methods like the Capability Maturity Model have introduced processes and strategies that require measurement in the form of software metrics. With the ever increasing number of software metrics being introduced by capability based processes, software development organisations are finding it more difficult to understand and interpret metric scores. This is particularly problematic for senior management and project managers where analysis of the actual data is not feasible. This paper proposes a method with which to visually represent metric scores so that managers can easily see how their organisation is performing relative to quality goals set for each type of metric. Acting primarily as a proof of concept and prototype, we suggest ways in which real customer needs can be translated into a feasible technical solution. The solution itself visualises metric scores in the form of a tree structure and utilises Fuzzy Logic techniques, XGMML, Web Services and the .NET Framework. Future work is proposed to extend the system from the prototype stage and to overcome a problem with the masking of poor scores
RNA Interference by Single- and Double-stranded siRNA With a DNA Extension Containing a 3′ Nuclease-resistant Mini-hairpin Structure
Selective gene silencing by RNA interference (RNAi) involves double-stranded small interfering RNA (ds siRNA) composed of single-stranded (ss) guide and passenger RNAs. siRNA is recognized and processed by Ago2 and C3PO, endonucleases of the RNA-induced silencing complex (RISC). RISC cleaves passenger RNA, exposing the guide RNA for base-pairing with its homologous mRNA target. Remarkably, the 3' end of passenger RNA can accommodate a DNA extension of 19-nucleotides without loss of RNAi function. This construct is termed passenger-3'-DNA/ds siRNA and includes a 3'-nuclease-resistant mini-hairpin structure. To test this novel modification further, we have now compared the following constructs: (I) guide-3'-DNA/ds siRNA, (II) passenger-3'-DNA/ds siRNA, (III) guide-3'-DNA/ss siRNA, and (IV) passenger-3'-DNA/ss siRNA. The RNAi target was SIRT1, a cancer-specific survival factor. Constructs I-III each induced selective knock-down of SIRT1 mRNA and protein in both noncancer and cancer cells, accompanied by apoptotic cell death in the cancer cells. Construct IV, which lacks the SIRT1 guide strand, had no effect. Importantly, the 3'-DNA mini-hairpin conferred nuclease resistance to constructs I and II. Resistance required the double-stranded RNA structure since single-stranded guide-3'-DNA/ss siRNA (construct III) was susceptible to serum nucleases with associated loss of RNAi activity. The potential applications of 3'-DNA/siRNA constructs are discussed. Molecular Therapy-Nucleic Acids (2014) 2, e141; doi:10.1038/mtna.2013.68; published online 7 January 2014
Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer
Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors
Stability of fluorescence of sodium salicylate
Sodium salicylate fluorescence stability over long periods of time - prevention of contamination by impuritie
Catalytically active peptide–gold nanoparticle conjugates: Prospecting for artificial enzymes
The self‐assembly of peptides onto the surface of gold nanoparticles has emerged as a promising strategy towards the creation of artificial enzymes. The resulting high local peptide density surrounding the nanoparticle leads to cooperative and synergistic effects, which result in rate accelerations and distinct catalytic properties compared to the unconjugated peptide. This Minireview summarizes contributions to and progress made in the field of catalytically active peptide–gold nanoparticle conjugates. The origin of distinct properties, as well as potential applications, are also discussed
- …
