252 research outputs found

    Long-term follow-up after active surveillance or curative treatment: quality-of-life outcomes of men with low-risk prostate cancer

    Get PDF
    Purpose: To compare long-term (4–10 years) quality of life (QoL) of men with low-risk prostate cancer (PCa) treated by different modalities and a reference group without PCa. Methods: In this cross-sectional study, four groups were sent a one-time QoL-questionnaire; PCa patients (1) following the structured Prostate cancer Research International Active Surveillance protocol, (2) who underwent radical prostatectomy (RP) in the context of t

    Hypofractionated radiotherapy for prostate cancer: How far can we go?

    Get PDF

    Hvordan påvirkes prestasjonen ved et 25 minutters løp av korte innslag av anaerobe arbeid?

    Get PDF
    Masteroppgave - Norges idrettshøgskole, 2021Introduksjon: De bestemmende faktorene for prestasjonen i kondisjonsidretter er grovt inndelt: Det maksimale oksygenopptaket, utnyttingsgraden, den anaerobe kapasiteten og arbeidsøkonomien. Hittil har melkesyrekonsentrasjonen i blodet blitt brukt som et indirekte mål på utnyttingsgraden, og utnyttingsgraden har i mindre grad blitt målt direkte. Alle studier av utnyttingsgraden så vidt oss bekjent, har blitt gjennomført med en konstant intensitet. I praksis er det derimot svært vanskelig å holde en jevn intensitet i idretter som f.eks. langrenn, orientering og terrengsykling. Hensikten med denne studien var derfor å måle utnyttingsgraden direkte, og undersøke hvordan prestasjonen ville påvirkes av tre anaerobe arbeidsinnslag, ved en prestasjonstest på ca. 25 minutter. Metode: Syv godt trente løpere, en kvinne og seks menn (VO2maks: 73 ± 4,46 ml/kg*min, alder: 27,9 ± 2,85 år, kroppsmasse: 66,7 ± 9,02 kg) gjennomførte en screening-, tilvenning-, og to eksperimentelle dager, hvor alle tester ble gjennomført på tredemølle. Dag 1 inneholdt en laktatprofil og VO2mkas-test. På bakgrunn av disse resultatene ble det beregnet en distanse til hver deltager, som ville ta om lag 25 minutter å gjennomføre. På dag 2 fikk deltagerne teste farten i 15-20 minutter, samt øvd på å styre farten selv. På dag 3 og 4 ble det gjennomført en prestasjonstest uten/med anaerobe arbeidsinnslag (105% av VO2maks) på 30 sek x 3, med mål om å gjennomføre den beregna distansen (6500-7300 m) så raskt som mulig. Ventilasjonen og oksygenopptaket ble målt kontinuerlig ved begge tester. HF ble registrert hvert minutt og [La-] målt 1 minutt før hver spurt. Resultater: Tiden var 25,4 ± 0,925 min og 25,2 ± 0,894 min (p = 0,081) henholdsvis for testen med og uten spurter, men ikke signifikant forskjellig. Det var heller ingen signifikante forskjeller i akkumulert VO2, gjennomsnittlig arbeidsøkonomi, utnyttingsgrad, hjertefrekvens, ventilasjon eller laktat mellom prestasjonstesten uten og med spurter. Konklusjon: Tre korte perioder (30 s) med anaerobt bidrag (105% av VO2maks) har liten betydning for prestasjonen (0,9%; p = 0,08) ved løp mellom 6500-7300 m. Dette indikerer at korte spurter underveis i et løp, f.eks. for å hente inn teten eller rykke ifra, kan være en god «pacing-strategi», uten at det påvirker prestasjonen negativt.Institutt for fysisk prestasjonsevne / Department of Physical Performanc

    Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time

    Get PDF
    Purpose: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). Methods: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified. Results: For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65°/30° and 295°/-30°, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum Dmean, D1cc, V40GyEq and V60GyEq were 19.4 ± 10.6%, 4.2 ± 2.7%, 34.9 ± 20.3%, and 39.7 ± 23.2%, respectively (all p&lt;0.001). There was no difference in bladder D1cc, while bladder Dmean reduced by 17.9 ± 11.0% (p&lt;0.001). Also, the clinically evaluated urethra D5%, D10%, and D50% showed small, but statistically significant improvements. All patient VX with X = 2, 5, 10, 20, and 30 Gy were reduced with VMAT+CS, with a maximum relative reduction for V10Gy of 19.0 ± 7.3% (p&lt;0.001). Total delivery times with VMAT+CS only increased by 1.9 ± 0.7 min compared to VMAT (9.1 ± 0.7 min). The dosimetric quality of VMAT+CS plans was equivalent to VMAT+5, while optimization times were reduced by a factor of 25 due to avoidance of individualized BAO. Compared to VMAT+CS, the 30-NCP plans were only favorable in terms of dose bath, at the cost of much enhanced optimization and delivery times. Conclusions: The proposed two-beam non-coplanar class solution to complement coplanar dual-arc VMAT resulted in substantial plan quality improvements for OARs (especially rectum) and reduced irradiated patient volumes with minor increases in treatment delivery times.</p

    M1a prostate cancer:Results of a Dutch multidisciplinary consensus meeting

    Get PDF
    ObjectivesTo determine the consensus of a Dutch multidisciplinary expert panel on the diagnostic evaluation and treatment of de novo and recurrent metastatic prostate cancer (PCa) limited to non-regional lymph nodes (M1a) in daily clinical practice.Materials and methodsThe panel consisted of 37 Dutch specialists from disciplines involved in the management of M1a PCa (urology, medical and radiation oncology, radiology, and nuclear medicine). We used a modified Delphi method consisting of two voting rounds and a consensus meeting (video conference). Consensus (good agreement) was defined as the situation in which ≥ 75% of the panelists chose the same option.ResultsConsensus existed for 57% of the items. The panel agreed that prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA-PET/CT) is the most appropriate standard imaging modality to identify de novo (100%) and recurrent (97%) M1a PCa. Androgen deprivation therapy (ADT) combined with radiotherapy to the prostate ± the M1a lesion(s) was most frequently considered an option for de novo M1a PCa. For M1a as recurrent disease, ADT alone, deferring treatment, or local radiotherapy to the M1a lesion(s) were judged to be the most important treatment options. However, no specific indications for treatment choice in relation to disease characteristics could be formulated.ConclusionsThe Dutch consensus panel preferred PSMA-PET/CT as the standard diagnostic modality to detect M1a PCa. Although potential treatment options were identified, explicit recommendations could not be formulated. This might (partly) be explained by the absence of high-level clinical evidence in this subset of patients. Further research is, therefore, strongly encouraged

    Skeletal <sup>18</sup>F-PSMA-1007 uptake in prostate cancer patients

    Get PDF
    Background/objectives: Accurate and uniform interpretation and reporting of metastatic prostate cancer (PCa) lesions on prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) are indispensable. 18F-PSMA-1007 is increasingly used because of its favorable imaging characteristics. However, increased non-specific skeletal uptake may be an important pitfall of this radioligand. Therefore, we aimed to assess the interobserver variation in reporting skeletal 18F-PSMA-1007 uptake on PET/CT.Design/methods: In total, 33 18F-PSMA-1007 PET/CT scans of 21 patients with primary PCa and 12 patients with biochemical recurrence were included, and a total of 85 skeletal lesions were evaluated by three independent observers. The primary endpoint was the interobserver variability of the likelihood of malignancy of the skeletal lesions on both patient and lesion level (kappa analysis).Results: Observers qualified most lesions as not malignant (81–91%) and the overall mean interobserver agreement was moderate on both patient (κ: 0.54) and lesion level (κ: 0.55). In 52 lesions without corresponding CT substrate, the rating resulted in not malignant in 95–100%. Availability of additional imaging (60% of lesions) did not improve interobserver agreement (κ: 0.39 on lesion level) and resulted in unchanged rating for all observers in 78%.Conclusion: This interobserver analysis of skeletal 18F-PSMA-1007 uptake resulted in moderate agreement, in line with rates reported in literature. Importantly, the presence of non-specific skeletal uptake without CT substrate, as a potential shortcoming of 18F-PSMA-1007, did not impair interobserver agreement.</p

    Oligometastatic Prostate Cancer:Results of a Dutch Multidisciplinary Consensus Meeting

    Get PDF
    Background: Oligometastatic prostate cancer (OMPC) is a heterogeneous disease state that is imperfectly understood, and its clinical implications are unclear. Objective: To determine the consensus of a Dutch multidisciplinary expert panel on biological aspects, treatment goals, and management of OMPC in daily clinical practice. Design, setting, and participants: The study comprised a modified Delphi method including an explorative survey with various statements and questions, followed by a consensus meeting to discuss and determine the agreement with revised statements and related items. The panel consisted of 34 Dutch representatives from urology, medical and radiation oncology, radiology, nuclear medicine, and basic research. Outcome measurements and statistical analysis: Agreement was determined with statements (five-point scale). Consensus was defined as ≥75% panel agreement with a statement. Results and limitations: Consensus existed for 56% of statements. The panel agreed that OMPC comprises a limited metastatic spread in the hormone-sensitive setting, in both the synchronous and the metachronous presentation. Limited metastatic spread was believed to involve three to five metastases and a maximum of two organs. Prostate-specific membrane antigen positron emission tomography/computed tomography scan was currently perceived as the most accurate diagnostic imaging modality. Although there was a consensus that targeted treatment of all metastases in OMPC will delay further dissemination of the disease, opinions on specific treatment regimens were divided. Panel outcomes were limited by the lack of scientific evidence on OMPC. Conclusions: A multidisciplinary panel reached a consensus that OMPC is a specific disease state requiring a tailored treatment approach. OMPC registries and clinical studies should focus on both the biology and the clinical parameters in relation to optimal treatment strategies in synchronous and metachronous OMPC. Patient summary: A group of Dutch medical specialists agreed that prostate cancer patients having few metastases may benefit from a new therapeutic approach. Clinical studies need to determine which treatment is best for each specific situation. A multidisciplinary panel reached consensus that oligometastatic prostate cancer (OMPC) is a specific disease state requiring a tailored treatment approach. OMPC registries and clinical studies should provide insight into the biology and clinical parameters in relation to optimal treatment strategies in synchronous and metachronous OMPC

    Inter-fraction motion robustness and organ sparing potential of proton therapy for cervical cancer

    Get PDF
    Purpose: Large-field photon radiotherapy is current standard in the treatment of cervical cancer patients. However, with the increasing availability of Pencil Beam Scanning Proton Therapy (PBS-PT) and robust treatment planning techniques, protons may have significant advantages for cervical cancer patients in the reduction of toxicity. In this study, PBS-PT and photon Volumetric Modulated Arc Therapy (VMAT) were compared, examining target coverage and organ at risk (OAR) dose, taking inter- and intra-fraction motion into account. Materials and methods: Twelve cervical cancer patients were included in this in-silico planning study. In all cases, a planning CT scan, five weekly repeat CT scans (reCTs) and an additional reCT 10 min after the first reCT were available. Two-arc VMAT and robustly optimised two- and four-field (2F and 4F) PBS-PT plans were robustly evaluated on planCTs and reCTs using set-up and range uncertainty. Nominal OAR doses and voxel-wise minimum target coverage robustness were compared. Results: Average voxel-wise minimum accumulated doses for pelvic target structures over all patients were adequate for both photon and proton treatment techniques (D98 > 95%, [91.7–99.3%]). Average accumulated dose of the para-aortic region was lower than the required 95%, D98 > 94.4% [91.1–98.2%]. With PBS-PT 4F, dose to all OARs was significantly lower than with VMAT. Major differences were observed for mean bowel bag V15Gy: 60% [39–70%] for VMAT vs 30% [10–52%] and 32% [9–54%] for PBS-PT 2F and 4F and for mean bone marrow V10Gy: 88% [82–97%] for VMAT vs 66% [60–73%] and 67% [60–75%] for PBS-PT 2F and 4F. Conclusion: Robustly optimised PBS-PT for cervical cancer patients shows equivalent target robustness against inter- and intra-fraction variability compared to VMAT, and offers significantly better OAR sparing
    corecore