230 research outputs found
A comparison of force-deflection relationships in half-round dental clasps, in vitro, fabricated by two casting methods
Introduction. From a clinical stand point it is important to know if the different casting techniques, using the same alloy, may change the stiffness of the cast denture clasp. Although rotary and vacuum-pressure casting methods have the same induction melting means, any similarity ends at this point. In the rotary method, the melting and casting process is carried out in air but for the vacuum-pressure method, melting is conducted in the vacuum and casting is done in forming gas. Aim of the study. The aim of this study was to compare the influence of two casting methods: a rotary-centrifugal method and a vacuum-pressure method on the deflection force of a straight clasp profile in vitro and disclose any differences in microstructure of cobalt chromium alloy cast profiles caused by using different casting technology. Material and Methods. A commercial cobalt-chromium alloy (Wironit® extrahard BEGO, Bremen, Germany) was used. The tested material were the straight clasp profiles of a half-round section, cast in standard wax patterns (BEGO, Bremen, Germany), by the use of two inductive casting devices: a vacuum-pressure microprocessor assisted method (VP) (in device Nautilus®-BEGO, Bremen, Germany) and a rotary (R) manually operated method (in device Fornax®-BEGO, Bremen, Germany). Thirteen castings were fabricated by each of the respective methods. The custom made measuring instrument consisted of a micrometer screw and an force into voltage extensometer converter was applied. After deflection force measurement chosen profiles undergone metallographic examination to reveal internal grain arrangements in them. Results. On the level of significance p = 0.05 the observed difference between the means was proved to be statistically significant with better results for vacuum-pressure method. The microstructure varied, and these differences correlated with differences in deflection force measurement with greater deflection force for bigger grains. The grains size of the samples was of different size from small to large
Speciation analysis of mercury in water samples by dispersive liquid-liquid microextraction coupled to capillary electrophoresis
In this study, a method of pretreatment and speciation analysis of mercury by dispersive liquid-liquid microextraction along with CE was developed. The method was based on the fact that mercury species including methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and Hg(II) were complexed with 1-(2-pyridylazo)-2-naphthol to form hydrophobic chelates and l-cysteine could displace 1-(2-pyridylazo)-2-naphthol to form hydrophilic chelates with the four mercury species. Factors affecting complex formation and extraction efficiency, such as pH value, type, and volume of extractive solvent and disperser solvent, concentration of the chelating agent, ultrasonic time, and buffer solution were investigated. Under the optimal conditions, the enrichment factors were 102, 118, 547, and 46, and the LODs were 1.79, 1.62, 0.23, and 1.50 g/L for MeHg, EtHg, PhHg, and Hg(II), respectively. Method precisions (RSD, n = 5) were in the range of 0.29-0.54% for migration time, and 3.08-7.80% for peak area. Satisfactory recoveries ranging from 82.38 to 98.76% were obtained with seawater, lake, and tap water samples spiked at three concentration levels, respectively, with RSD (n = 5) of 1.98-7.18%. This method was demonstrated to be simple, convenient, rapid, cost-effective, and environmentally benign, and could be used as an ideal alternative to existing methods for analyzing trace residues of mercury species in water samples.In this study, a method of pretreatment and speciation analysis of mercury by dispersive liquid-liquid microextraction along with CE was developed. The method was based on the fact that mercury species including methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and Hg(II) were complexed with 1-(2-pyridylazo)-2-naphthol to form hydrophobic chelates and l-cysteine could displace 1-(2-pyridylazo)-2-naphthol to form hydrophilic chelates with the four mercury species. Factors affecting complex formation and extraction efficiency, such as pH value, type, and volume of extractive solvent and disperser solvent, concentration of the chelating agent, ultrasonic time, and buffer solution were investigated. Under the optimal conditions, the enrichment factors were 102, 118, 547, and 46, and the LODs were 1.79, 1.62, 0.23, and 1.50 g/L for MeHg, EtHg, PhHg, and Hg(II), respectively. Method precisions (RSD, n = 5) were in the range of 0.29-0.54% for migration time, and 3.08-7.80% for peak area. Satisfactory recoveries ranging from 82.38 to 98.76% were obtained with seawater, lake, and tap water samples spiked at three concentration levels, respectively, with RSD (n = 5) of 1.98-7.18%. This method was demonstrated to be simple, convenient, rapid, cost-effective, and environmentally benign, and could be used as an ideal alternative to existing methods for analyzing trace residues of mercury species in water samples
A closer look at how the dispersive liquid–liquid microextraction method works. Investigation of the effect of solvent mixture composition on the quality and stability of the cloudy state
The dispersive liquid–liquid microextraction (DLLME) is one of the most popular miniaturized extraction procedures. In this paper, the degree of dispersion and dispersion stability were studied with the aim to assess the correlations of these parameters with efficiency for the selected analytical application. The dependence between the degree of dispersion (cloudy state quality) and its stability obtained by various emulsification procedures, such as solvent-assisted emulsification (using various dispersive solvents) and mechanical emulsification (using auxiliary energies), is investigated and discussed. It was found out that the degree of dispersion depends on the type of emulsification procedure and decreases in the series: solvent-assisted (SA-) = ultrasound-assisted (UA-) > air-assisted (AA-) > vortex-assisted (VA-) emulsification. The emulsion stability depends on the degree of dispersion and there were 1810 and 2070 s for the most effective emulsification procedures, such us solvent-assisted and ultrasound-assisted emulsification, respectively. A comparison between the sensitivity of the analytical methods (using spectrophotometric determination of the anionic surfactants) and the degree of dispersion have been made. The sensitivity of the methods was ranked as follows: DLLME > UA-LLME > VA-LLME > AA-LLME
Investigation of the acid-base properties of 2-[2-(4-methoxy-phenylamino)-vinyl]-1,3,3-trimethyl-3H-indolium reagent
Deep eutectic solvent-based shaking-assisted extraction for determination of bioactive compounds from Norway spruce roots
Polyphenolic compounds play an essential role in plant growth, reproduction, and defense mechanisms against pathogens and environmental stresses. Extracting these compounds is the initial step in assessing phytochemical changes, where the choice of extraction method significantly influences the extracted analytes. However, due to environmental factors, analyzing numerous samples is necessary for statistically significant results, often leading to the use of harmful organic solvents for extraction. Therefore, in this study, a novel DES-based shaking-assisted extraction procedure for the separation of polyphenolic compounds from plant samples followed by LC-ESI-QTOF-MS analysis was developed. The DES was prepared from choline chloride (ChCl) as the hydrogen bond acceptor (HBA) and fructose (Fru) as the hydrogen bond donor (HBD) at various molar ratios with the addition of 30% water to reduce viscosity. Several experimental variables affecting extraction efficiency were studied and optimized using one-variable-at-a-time (OVAT) and confirmed by response surface design (RS). Nearly the same experimental conditions were obtained using both optimization methods and were set as follows: 30 mg of sample, 300 mg of ChCl:Fru 1:2 DES containing 30% w/w of water, 500 rpm shaking speed, 30 min extraction time, 10°C extraction temperature. The results were compared with those obtained using conventional solvents, such as ethanol, methanol and water, whereby the DES-based shaking-assisted extraction method showed a higher efficiency than the classical procedures. The greenness of the developed method was compared with the greenness of existing procedures for the extraction of polyphenolic substances from solid plant samples using the complementary green analytical procedure index (ComplexGAPI) approach, while the results for the developed method were better or comparable to the existing ones. In addition, the practicability of the developed procedure was evaluated by application of the blue applicability grade index (BAGI) metric. The developed procedure was applied to the determination of spruce root samples with satisfactory results and has the potential for use in the analysis of similar plant samples
Trichotomy of nonoscillatory solutions to second-order neutral difference equation with quasi-difference
- …
