1,521 research outputs found

    Investigating and learning lessons from early experiences of implementing ePrescribing systems into NHS hospitals:a questionnaire study

    Get PDF
    Background: ePrescribing systems have significant potential to improve the safety and efficiency of healthcare, but they need to be carefully selected and implemented to maximise benefits. Implementations in English hospitals are in the early stages and there is a lack of standards guiding the procurement, functional specifications, and expected benefits. We sought to provide an updated overview of the current picture in relation to implementation of ePrescribing systems, explore existing strategies, and identify early lessons learned.Methods: a descriptive questionnaire-based study, which included closed and free text questions and involved both quantitative and qualitative analysis of the data generated.Results: we obtained responses from 85 of 108 NHS staff (78.7% response rate). At least 6% (n = 10) of the 168 English NHS Trusts have already implemented ePrescribing systems, 2% (n = 4) have no plans of implementing, and 34% (n = 55) are planning to implement with intended rapid implementation timelines driven by high expectations surrounding improved safety and efficiency of care. The majority are unclear as to which system to choose, but integration with existing systems and sophisticated decision support functionality are important decisive factors. Participants highlighted the need for increased guidance in relation to implementation strategy, system choice and standards, as well as the need for top-level management support to adequately resource the project. Although some early benefits were reported by hospitals that had already implemented, the hoped for benefits relating to improved efficiency and cost-savings remain elusive due to a lack of system maturity.Conclusions: whilst few have begun implementation, there is considerable interest in ePrescribing systems with ambitious timelines amongst those hospitals that are planning implementations. In order to ensure maximum chances of realising benefits, there is a need for increased guidance in relation to implementation strategy, system choice and standards, as well as increased financial resources to fund local activitie

    Antifungal activity of a novel chromene dimer

    Get PDF
    The activity on Aspergillus spp. growth and on ochratoxin A production of two novel chromene dimers (3) was evaluated. The results of the bioassays indicate that the chromene dimer 3a inhibited mycelia growth by approximately 50% (EC50) at 140.1 μmol L−1 for A. niger, 384.2 μmol L−1 for A. carbonarius, 69.1 μmol L−1 for A. alliaceus and 559.1 μmol L−1 for A. ochraceus. When applied at concentrations of 2 mmol L−1, 3a totally inhibited the growth of all Aspergillus spp. tested. Furthermore, ochratoxin A production by A. alliaceus was reduced by about 94% with a 200 μmol L−1 solution of this compound. A moderate inhibitory effect was observed for the analogous structure 3b on ochratoxin A production but not in mycelia growth. No inhibition was registered for compounds 2a and 2b, used as synthetic precursors of the dimeric species 3.Fundação para a Ciência e a Tecnologia (FCT) - SFRH/BD/ 11228/2002

    Mechanisms of spinal cord degeneration and repair in multiple sclerosis: A 3T MRI study of the spinal cord

    Get PDF
    The spinal cord is a clinically eloquent structure, commonly affected in multiple sclerosis (MS) and spinal neuroaxonal loss is an important cause of non-remitting, disability progression. Neuroaxonal loss in MS is likely to be multifactorial and caused by several disease pathways. In contrast, repair and adaptive mechanisms can ameliorate disability following clinical relapses. This thesis has explored some of these clinically relevant disease mechanisms by combining single-voxel proton spectroscopy (MRS) and Q-space imaging (QSI), two advanced MRI techniques, which have increased pathological specificity for neurodegeneration and myelin, and allow quantification of metabolites that reflect biological mechanisms, to study spinal neurodegeneration and repair in MS. In persons with early primary progressive MS (PPMS), spinal MRS and QSI exhibited increased sensitivity for detection of early disease changes than more conventional measures such as spinal cord atrophy and correlated with clinical disability measures suggesting these measures are functionally relevant. Region of interest analysis of the relationship between QSI indices in spinal white matter tracts and clinical scores which reflect the motor or sensory functions conveyed within those tracts, suggests a strong structure-function relationship exists between axonal integrity and disability. In persons with relapsing remitting MS (RRMS), with recent (within 4 weeks) symptoms suggestive of spinal cord relapse, serial imaging with spinal MRS and QSI over 6 months reflected clinical changes over that time. Specifically, rising spinal concentrations of total N-acetyl-aspartate (tNAA) and restriction of QSI-derived perpendicular diffusivity, which I hypothesise reflect, restoration of mitochondrial function and remyelination, respectively, underlie clinical recovery. Within the RRMS cohort, MRS and QSI measures at baseline were predictive of clinical outcomes at 6 months; elevated baseline spinal glutamate-glutamine (Glx), myo-inositol (Ins) and total creatine (tCr) concentrations and increased QSI-derived perpendicular diffusivity predicted poor outcomes and may reflect important mechanisms of disability progression such as; demyelination, neurodegeneration, astrogliosis and altered neuronal metabolism. Taken together the results suggest that mechanisms of disability following spinal cord relapse are complex and glutamate excitotoxicity, gliosis and axonal metabolic dysfunction may be important determinants of residual disability following relapses. This work suggests that newer, quantitative MRI techniques when applied to the spinal cord are sensitive markers of disease activity and progression and could be useful in monitoring therapies that aim to prevent neurodegeneration and enhance remyelination in MS

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Significant sequelae after bacterial meningitis in Niger: a cohort study

    Get PDF
    Beside high mortality, acute bacterial meningitis may lead to a high frequency of neuropsychological sequelae. The Sahelian countries belonging to the meningitis belt experience approximately 50% of the meningitis cases occurring in the world. Studies in Africa have shown that N. meningitidis could cause hearing loss in up to 30% of the cases, exceeding sometimes measles. The situation is similar in Niger which experiences yearly meningitis epidemics and where rehabilitation wards are rare and hearing aids remain unaffordable. The aim of this study was to estimate the frequency of neuropsychological sequelae after acute bacterial meningitis in four of the eight regions of Niger

    2019 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations : summary from the basic life support; advanced life support; pediatric life support; neonatal life support; education, implementation, and teams; and first aid task forces

    No full text
    The International Liaison Committee on Resuscitation has initiated a continuous review of new, peer-reviewed, published cardiopulmonary resuscitation science. This is the third annual summary of the International Liaison Committee on Resuscitation International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. It addresses the most recent published resuscitation evidence reviewed by International Liaison Committee on Resuscitation Task Force science experts. This summary addresses the role of cardiac arrest centers and dispatcher-assisted cardiopulmonary resuscitation, the role of extracorporeal cardiopulmonary resuscitation in adults and children, vasopressors in adults, advanced airway interventions in adults and children, targeted temperature management in children after cardiac arrest, initial oxygen concentration during resuscitation of newborns, and interventions for presyncope by first aid providers. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the certainty of the evidence on the basis of the Grading of Recommendations, Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations. Insights into the deliberations of the task forces are provided in the Justification and Evidence to Decision Framework Highlights sections. The task forces also listed priority knowledge gaps for further research

    An Easy and Efficient Method for Native and Immunoreactive Echinococcus granulosus Antigen 5 Enrichment from Hydatid Cyst Fluid

    Get PDF
    Background: Currently, the serodiagnosis of cystic echinococcosis relies mostly on crude Echinococcus granulosus hydatid cyst fluid as the antigen. Consequently, available immunodiagnostic tests lack standardization of the target antigen and, in turn, this is reflected on poor sensitivity and specificity of the serological diagnosis. Methodology/Principal Findings: Here, a chromatographic method enabling the generation of highly enriched Antigen 5 (Ag5) is described. The procedure is very easy, efficient and reproducible, since different hydatid cyst fluid (HCF) sources produced very similar chromatograms, notwithstanding the clearly evident and extreme heterogeneity of the starting material. In addition, the performance of the antigen preparation in immunological assays was preliminarily assessed by western immunoblotting and ELISA on a limited panel of cystic echinococcosis patients and healthy controls. Following western immunoblotting and ELISA experiments, a high reactivity of patient sera was seen, with unambiguous and highly specific results. Conclusions/Significance: The methods and results reported open interesting perspectives for the development of sensitive diagnostic tools to enable the timely and unambiguous detection of cystic echinococcosis antibodies in patient sera.This work was supported by Regione Autonoma della Sardegna (http://www.regione.sardegna.it/)Pubblicat

    Evidence for eosinophil and IL-17 mediated inflammation in allergic rhinitis.

    Get PDF
    Background: The aim was to determine the level of inflammatory cytokines, eosinophil cationic protein and IgE in allergic rhinitis (AR) patients. Subjects and methods: Blood samples were taken from 88 AR patients and 88 healthy controls (HC). Each sample was analysed for eosinophil counts by flow cytometry, IgE by ECLIA, ECP, IL-17, and IL-33 by using ELISA test. Results: There was no significant difference between AR patients and the control group in age and gender. Levels of eosinophils, IgE, ECP, IL-17, IL-33 and the total symptom scores were significantly higher in AR patients than the HC (P = 0.0001). Serum ECP correlated with IL-17 (P = 0.041, r = 0.42), IL-33 (P = 0.0001, r = 080), and IgE levels (P = 0.017, r = 0.45) in the R patients. There was no correlation between IL-17 and IL-33. There was a correlation between symptom scores and eosinophils (P = 0.026, r = 0.52), and IgE (P = 0.001, r = 0.60) in the patients. No correlation was observed between symptom scores and ECP, IL-17, and IL-33 in the AR patient. Conclusions: Patients with AR have significant higher serum levels of ECP, IL-17, and IL-33 than healthy controls. This indicates that these markers could be used to in order to diagnose AR and to monitor disease. Inhibitory molecules to IL-17 and IL-33 may be considered as novel treatment strategies

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    corecore