434 research outputs found

    Transverse Magnetic Anisotropy in Mn12-acetate: Direct Determination by Inelastic Neutron Scattering

    Full text link
    A high resolution inelastic neutron scattering (INS) study of fully deuterated Mn12_{12}-acetate provides the most accurate spin Hamiltonian parameters for this prototype single molecule magnet so far. The Mn12_{12}-clusters deviate from axial symmetry, a non-zero rhombic term in the model Hamiltonian leading to excellent agreement with observed positions and intensities of the INS peaks. The following parameter set provides the best agreement with the experimental data: D=0.0570(1)D=-0.0570(1) meV, B40=2.78(7)106B_{4}^0=-2.78(7)\cdot 10^{-6} meV, B44=3.2(6)106B_{4}^4=-3.2(6)\cdot 10^{-6} meV and \mid\textit{E}=6.8(15)104\mid =6.8(15)\cdot 10^{-4} meV. Crystal dislocations are not the likely cause of the symmetry lowering. Rather, this study lends strong support to a recently proposed model, which is based on the presence of several molecular isomers with distinct spin Hamiltonian parameters.Comment: 4 pages, 4 figure

    Investigating Complex Geometrical Features in LPBF-Produced Parts: A Material-Based Comparison Between Different Titanium Alloys

    Get PDF
    The Ti–6Al–4V (Ti64) alloy is a well-established material to be processed via laser powder bed fusion (LPBF). Recently, other α + β titanium alloys are receiving attention, such as Ti–6Al–2Sn–4Zr–6Mo (Ti6246). Their typical industrial fields of application (aerospace, automotive), often require critical design choices, such as low wall thicknesses and hollow channels. Thus, a comparative analysis between these two competitor alloys in terms of processability was conducted in this work. To do so, specific sample designs were developed. The specimens were analyzed in terms of geometrical compliance with the initial design, porosity, and microstructure. A correlation between the width of the specimens and their porosity, micro- structure and hardness was found. Overall, both the alloys proved to be well processable, even for very low wall thickness (300 μm) and channel diameter (1 mm) values. Nevertheless, the Ti6246 alloy seemed to behave better in specific scenarios. For instance, some Ti64 specimens provided delamination. The hollow channels proved to be challenging for both materi- als, mainly due to the high amount of residual powder particles adhered to the upper part of the holes. This works aims at giving a materials perspective on process-related issues, considering the LPBF-induced defectology and microstructural variations in these Ti alloys

    Joint Sentinel-1 and SMAP data assimilation to improve soil moisture estimates

    Get PDF
    SMAP (Soil Moisture Active and Passive) radiometer observations at similar to 40 km resolution are routinely assimilated into the NASA Catchment Land Surface Model to generate the 9 km SMAP Level-4 Soil Moisture product. This study demonstrates that adding high-resolution radar observations from Sentinel-1 to the SMAP assimilation can increase the spatiotemporal accuracy of soil moisture estimates. Radar observations were assimilated either separately from or simultaneously with radiometer observations. Assimilation impact was assessed by comparing 3-hourly, 9 km surface and root-zone soil moisture simulations with in situ measurements from 9 km SMAP core validation sites and sparse networks, from May 2015 to December 2016. The Sentinel-1 assimilation consistently improved surface soil moisture, whereas root-zone impacts were mostly neutral. Relatively larger improvements were obtained from SMAP assimilation. The joint assimilation of SMAP and Sentinel-1 observations performed best, demonstrating the complementary value of radar and radiometer observations

    Methodology of calculation of construction and hydrodynamic parameters of a foam layer apparatus for mass-transfer processes

    Get PDF
    Промислова реалізація методу стабілізації газорідинного шару дозволяє значно розширити галузь застосування пінних апаратів і відкриває нові можливості інтенсифікації технологічних процесів з одночасним створенням маловідходних технологій. У статті встановлені основні параметри, що впливають на гідродинаміку пінних апаратів, розглянуті основні конструкції та режими роботи пінних апаратів. Виявлено зв'язок гідродинамічних параметрів. Розглянуто гідродинамічні закономірності пінного шару. Вказані фактори, що впливають на процес масообміну, як в газовій, так і в рідкій фазах. Проведений аналіз ряду досліджень показав, що перспективним напрямком інтенсифікації процесу масообміну є розробка апаратів з трифазним псевдозрідженим шаром зрошуваної насадки складних форм із сітчастих матеріалів. Отже, необхідне проведення спеціальних досліджень гідродинамічних режимів роботи апарату з сітчастою насадкою і визначенням параметрів, що впливають на швидкість переходу насадки з одного режиму в інший.Industrial implementation of the stabilization method of the gas-liquid layer can significantly expand the field of use of foaming apparatus and opens up new opportunities for intensifying technological processes with the simultaneous creation of low-waste technologies. The article establishes the basic parameters influencing the hydrodynamics of foam apparatus, considers the basic constructions and operating modes of foam apparatus. The connection of hydrodynamic parameters is revealed. The hydrodynamic laws of the foam layer are considered. The indicated factors affecting the process of mass transfer, both in the gas and in the liquid phases. The conducted analysis of a number of studies showed that the perspective direction of intensification of the mass transfer process is the development of apparatuses with a three-phase fluidized bed of an irrigated nozzle of complex forms with mesh materials

    A literature review and expert consensus statement on diagnostics in suspected metal implant allergy

    Get PDF
    Background Although rare, allergic reactions to metal implants represent a diagnostic challenge in view of missing guidelines. Objectives To develop an European expert consensus on characteristics of metal allergy reactions and the utility of various diagnostic tools in suspected metal implant allergy. Methods A nominal group technique (NGT) was applied to develop consensus statements. Initially an online literature database was created on a secure server to enable a comprehensive information. Twenty-three statements were formulated on potential aspects of metal implant allergy with a focus on diagnostics and grouped into five domains. For the consensus development, the panel of 12 experts initially did refine and reformulate those statements that were ambiguous or had unclear wording. By face-to-face (9/12) or virtual participation (3/12), an anonymous online voting was performed. Results Consensus (≥80% of agreement) was reached in 20/23 statements. The panel agreed that implant allergy despite being rare should be considered in case of persistent unexplained symptoms. It was, however, recommended to allow adequate time for resolution of symptoms associated with healing and integration of an implant. Obtaining questionnaire-aided standardized medical history and standardized scoring of patient outcomes was also considered an important step by all experts There was broad consensus regarding the utility/performance of patch testing with additional late reading. It was recognized that the lymphocyte transformation test (LTT) has to many limitations to be generally recommended. Prior to orthopaedic implant, allergy screening of patients without a history of potential allergy to implant components was not recommended. Conclusions Using an expert consensus process, statements concerning allergy diagnostics in suspected metal implant allergy were created. Areas of nonconsensus were identified, stressing uncertainty among the experts around topics such as preoperative testing in assumed allergy, histological correlate of periimplant allergy and in vitro testing, which underscores the need for further research

    Bringing the commercial determinants of health out of the shadows : a review of how the commercial determinants are represented in conceptual frameworks

    Get PDF
    BACKGROUND: The term 'commercial determinants of health' (CDOH) is increasingly focussing attention upon the role of tobacco, alcohol and food and beverage companies and others-as important drivers of non-communicable diseases (NCDs). However, the CDOH do not seem to be clearly represented in the most common social determinants of health (SDOH) frameworks. We review a wide range of existing frameworks of the determinants of health to determine whether and how commercial determinants are incorporated into current SDOH thinking. METHODS: We searched for papers and non-academic reports published in English since 2000 describing influences on population health outcomes. We included documents with a formal conceptual framework or diagram, showing the integration of the different determinants. RESULTS: Forty-eight framework documents were identified. Only one explicitly included the CDOH in a conceptual diagram. Ten papers discussed the commercial determinants in some form in the text only and fourteen described negative impacts of commercial determinants in the text. Twelve discussed positive roles for the private sector in producing harmful commodities. Overall, descriptions of commercial determinants are frequently understated, not made explicit, or simply missing. The role of commercial actors as vectors of NCDs is largely absent or invisible in many of the most influential conceptual diagrams. CONCLUSIONS: Our current public health models may risk framing public health problems and solutions in ways that obscure the role that the private sector, in particular large transnational companies, play in shaping the broader environment and individual behaviours, and thus population health outcomes

    The contribution of the environment (especially diet) to breast cancer risk

    Get PDF
    Environmental factors play an important role in breast carcinogenesis. Opportunities for prevention are limited, however, because most of the known or suspected risk factors are not targets for modification. Dietary factors have generally not emerged as crucial contributors to mammary tumor causation. We still appear to be missing a critical piece of the breast cancer puzzle because we can only explain a moderate proportion of international and national variation in breast cancer rates. Research needs to pursue new avenues, focusing on exposure windows that have not yet been sufficiently explored, such as events between conception and adolescence, and on modifiable risk factors that show large variation within or between populations

    Nutritional behavior of cyclists during a 24-hour team relay race: a field study report

    Get PDF
    Background Information about behavior of energy intake in ultra-endurance cyclists during a 24-hour team relay race is scarce. The nutritional strategy during such an event is an important factor which athletes should plan carefully before the race. The purpose of this study was to examine and compare the nutritional intake of ultra-endurance cyclists during a 24-hour team relay race with the current nutritional guidelines for endurance events. Additionally, we analyzed the relationship among the nutritional and performance variables. Methods Using a observational design, nutritional intake of eight males (mean ± SD: 36.7 ± 4.7 years; 71.6 ± 4.9 kg; 174.6 ± 7.3 cm; BMI 23.5 ± 0.5 kg/m2) participating in a 24-hour team relay cycling race was assessed. All food and fluid intake by athletes were weighed and recorded. Additionally, distance and speed performed by each rider were also recorded. Furthermore, before to the race, all subjects carried out an incremental exercise test to determine two heart rate-VO2 regression equations which were used to estimate the energy expenditure. Results The mean ingestion of macronutrients during the event was 943 ± 245 g (13.1 ± 4.0 g/kg) of carbohydrates, 174 ± 146 g (2.4 ± 1.9 g/kg) of proteins and 107 ± 56 g (1.5 ± 0.7 g/kg) of lipids, respectively. This amount of nutrients reported an average nutrient intake of 22.8 ± 8.9 MJ which were significantly lower compared with energy expenditure 42.9 ± 6.8 MJ (P = 0.012). Average fluid consumption corresponded to 10497 ± 2654 mL. Mean caffeine ingestion was 142 ± 76 mg. Additionally, there was no relationship between the main nutritional variables (i.e. energy intake, carbohydrates, proteins, fluids and caffeine ingestion) and the main performance variables (i.e. distance and speed). Conclusions A 24-hour hours cycling competition in a team relay format elicited high energy demands which were not compensated by energy intake of the athletes despite that dietary consumption of macronutrients did not differ to the nutritional guidelines for longer events
    corecore