1,241 research outputs found
Vertical axis wind turbine drive train transient dynamics
Start up of a vertical axis wind turbine causes transient torque oscillations in the drive train with peak torques which may be over two and one half times the rated torque of the turbine. A computer code, based on a lumped parameter model of the drive train, was developed and tested for the low cost 17 meter turbine; the results show excellent agreement with field data. The code was used to predict the effect of a slip clutch on transient torque oscillations. It was demonstrated that a slip clutch located between the motor and brake can reduce peak torques by thirty eight percent
Resonant isolator for maser amplifier
An isolator is described for use in a low noise maser amplifier, which provides low loss across a wide bandwidth and which can be constructed at moderate cost. The isolator includes a train of garnet or ferrite elements extending along the length of a microwave channel parallel to the slow wave structure, with the elements being of staggered height, so that the thin elements which are resonant to the microwaves are separated by much thicker elements. The thick garnet or ferrite elements reduce the magnetic flux passing through the thin elements to permit altering of the shape of the thin elements so as to facilitate their fabrication and to provide better isolation with reduced loss, by increasing the thickness of the thin elements and decreasing their length and width
Improved masers for X-band and Ku band
Slow-wave structure of traveling-wave maser utilizes comb system which is comprised of ruby on one side and alumina on other; alumina also supports isolator material. Radiation at pump frequency is coupled to ruby through shaped alumina strips. Contact between ruby bars and comb completes conductance path for heat transfer
Dielectric-loaded waveguide circulator for cryogenically cooled and cascaded maser waveguide structures
A dielectrically loaded four port waveguide circulator is used with a reflected wave maser connected to a second port between first and third ports to form one of a plurality of cascaded maser waveguide structures. The fourth port is connected to a waveguide loaded with microwave energy absorbing material. The third (output signal) port of one maser waveguide structure is connected by a waveguide loaded with dielectric material to the first (input) port of an adjacent maser waveguide structure, and the second port is connected to a reflected wave maser by a matching transformer which passes the signal to be amplified into and out of the reflected wavemaser and blocks pumping energy in the reflected wave maser from entering the circulator. A number of cascaded maser waveguide structures are thus housed in a relatively small volume of conductive material placed within a cryogenically cooled magnet assembly
Rogue Waves: From Nonlinear Schrödinger Breather Solutions to Sea-Keeping Test
Under suitable assumptions, the nonlinear dynamics of surface gravity waves can be modeled by the one-dimensional nonlinear Schrödinger equation. Besides traveling wave solutions like solitons, this model admits also breather solutions that are now considered as prototypes of rogue waves in ocean. We propose a novel technique to study the interaction between waves and ships/structures during extreme ocean conditions using such breather solutions. In particular, we discuss a state of the art sea-keeping test in a 90-meter long wave tank by creating a Peregrine breather solution hitting a scaled chemical tanker and we discuss its potential devastating effects on the ship
Staphylococcal biofilm formation on the surface of three different calcium phosphate bone grafts: a qualitative and quantitative in vivo analysis.
Differences in physico-chemical characteristics of bone grafts to fill bone defects have been demonstrated to influence in vitro bacterial biofilm formation. Aim of the study was to investigate in vivo staphylococcal biofilm formation on different calcium phosphate bone substitutes. A foreign-body guinea-pig infection model was used. Teflon cages prefilled with β-tricalcium phosphate, calcium-deficient hydroxyapatite, or dicalcium phosphate (DCP) scaffold were implanted subcutaneously. Scaffolds were infected with 2 × 10(3) colony-forming unit of Staphylococcus aureus (two strains) or S. epidermidis and explanted after 3, 24 or 72 h of biofilm formation. Quantitative and qualitative biofilm analysis was performed by sonication followed by viable counts, and microcalorimetry, respectively. Independently of the material, S. aureus formed increasing amounts of biofilm on the surface of all scaffolds over time as determined by both methods. For S. epidermidis, the biofilm amount decreased over time, and no biofilm was detected by microcalorimetry on the DCP scaffolds after 72 h of infection. However, when using a higher S. epidermidis inoculum, increasing amounts of biofilm were formed on all scaffolds as determined by microcalorimetry. No significant variation in staphylococcal in vivo biofilm formation was observed between the different materials tested. This study highlights the importance of in vivo studies, in addition to in vitro studies, when investigating biofilm formation of bone grafts
Collective responses of Bi-2212 stacked junction to 100 GHz microwave radiation under magnetic field oriented along the c-axis
We studied a response of Bi-2212 mesa type structures to 100 GHz microwave
radiation. We found that applying magnetic field of about 0.1 T across the
layers enables to observe collective Shapiro step response corresponding to a
synchronization of all 50 intrinsic Josephson junctions (IJJ) of the mesa. At
high microwave power we observed up to 10th harmonics of the fundamental
Shapiro step. Besides, we found microwave induced flux-flow step position of
which is proportional to the square root of microwave power and that can exceed
at high enough powers 1 THz operating frequency of IJJ oscillations.Comment: 11 pages including 5 figures, accepted for publication in JETP
Letter
Origin of Low-Energy Excitations in Charge-Ordered Manganites
The low-energy excitations in the charge-ordered phase of polycrystalline
La0.25Ca0.75MnO3 are explored by frequency-domain terahertz spectroscopy. In
the frequency range from 4 cm^-1 to 700 cm^-1 (energies 0.4 meV to 90 meV) and
at temperatures down to 5 K, we do not detect any feature that can be
associated with the collective response of the spatially modulated charge
continuum. In the antiferromagnetically ordered phase, broad absorption bands
appear in the conductivity and permittivity spectra around 30 cm^-1 and 100
cm^-1 which are assigned to former acoustic phonons optically activated due to
a fourfold superstructure in the crystal lattice. Our results indicate that
characteristic energies of collective excitations of the charge-ordered phase
in La0:25Ca0:75MnO3, if any, lie below 1 meV. At our lowest frequencies of only
few wavenumbers a strong relaxation is observed above 100 K connected to the
formation of the charge-ordered state.Comment: 5 pages, 3 figure
Reconstruction of body cavity volume in terrestrial tetrapods
tracts required for the digestion of plant fiber, this concept has not been addressed quantitatively. We estimated the volume of the torso in 126 terrestrial tetrapods (synapsids including basal synapsids and mammals, and diapsids including birds, non-avian dinosaurs and reptiles) classified as either herbivore or carnivore in digital models of mounted skeletons, using the convex hull method. The difference in relative torso volume between diet types was significant in mammals, where relative torso volumes of herbivores were about twice as large as that of carnivores, supporting the general hypothesis. However, this effect was not evident in diapsids. This may either reflect the difficulty to reliably reconstruct mounted skeletons in non-avian dinosaurs, or a fundamental difference in the bauplan of different groups of tetrapods, for example due to differences in respiratory anatomy. Evidently, the condition in mammals should not be automatically assumed in other, including more basal, tetrapod lineages. In both synapsids and diapsids, large animals showed a high degree of divergence with respect to the proportion of their convex hull directly supported by bone, with animals like elephants or Triceratops having a low proportion, and animals such as rhinoceros having a high proportion of bony support. The relevance of this difference remains to be further investigated
- …
