45 research outputs found
Analysis of a five year experience of permanent pacemaker implantation at a Nigerian Teaching Hospital: Need for a national database
Introduction: Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker datacollection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods: The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code. Results: Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%).Conclusion: Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry
Preliminary experience in the management of tracheobronchial foreign bodies in Lagos, Nigeria
Aspiration of tracheobronchial foreign bodies commonly affects young children, is potentially life threatening and requires early intervention for extraction. Access to facilities and skill manpower for bronchoscopic extraction is however limited in Nigeria. The aim of this study is to describe the experience in our institution with bronchoscopic removal of tracheobronchial foreign bodies and highlight the challenges encountered. This is a retrospective study of all patients referred to the Lagos State University Teaching Hospital with a diagnosis of tracheobronchial foreign body within the period of February 2008 and February 2013. Data extracted from the medical records were age, sex, time interval between aspiration and presentation, location of tracheobronchial foreign body, bronchoscopic technique, complications and outcome. A total of 24 patients were referred and confirmed at bronchoscopy to have tracheobronchial foreign bodies. Mean age was 6.6 + 5 years. Male to female ratio was 1:1. Delayed presentation was common with 22 patients (91.7%) presenting more than 24 hours after aspiration. Aspirated material was inorganic in 17 patients (70.8%) and organic in 7 patients (29.2%). Location of tracheobronchial foreign bodies was right main bronchus in 16 patients (66.7%), left main bronchus in 6 patients (25%) and the trachea in 2 patients (8.3%). Challenges to speedy and safe removal of the foreign bodies were delayed presentation and a limited range of bronchoscopic equipment early in the series which caused prolonged procedures and increased complications. Two mortalities occurred early in the series; one from airway obstruction and the other from respiratory failure caused by tracheobronchial oedema. Extraction of tracheobronchial foreign bodies was faster, more complete and safer later in the series due to a wider range of bronchoscopy equipment which included both flexible and rigid videobronchoscopy with the use of optical forceps. This preliminary experience suggests that an adequate armamentarium of bronchoscopy equipment is required to increase the chances of complete extraction, speed up the procedure and reduce the risk of complications of Tracheobronchial Foreign Bodies in our environment. Delayed presentation increases the difficulty of the procedure so earlier referral of these patients would help reduce the risk involved in their management.Key words: Bronchoscopy, Tracheobronchial Foreign Bodies, Lagos, Nigeri
Characterisation of heart failure with normal ejection fraction in a tertiary hospital in Nigeria
<p>Abstract</p> <p>Background</p> <p>The study aimed to determine the frequency and characteristics of heart failure with normal EF in a native African population with heart failure.</p> <p>Methods</p> <p>It was a hospital cohort study. Subjects were 177 consecutive individuals with heart failure and ninety apparently normal control subjects. All the subjects underwent transthoracic echocardiography. The group with heart failure was further subdivided into heart failure with normal EF (EF ≥ 50) (HFNEF) and heart failure with low EF(EF <50)(HFLEF).</p> <p>Results</p> <p>The subjects with heart failure have a mean age of 52.3 ± 16.64 years vs 52.1 ± 11.84 years in the control subjects; p = 0.914. Other baseline characteristics except blood pressure parameters and height were comparable between the group with heart failure and the control subjects. The frequency of HFNEF was 39.5%. Compared with the HFLEF group, the HFNEF group have a smaller left ventricular diameter (in diastole and systole): (5.2 ± 1.22 cm vs 6.2 ± 1.39 cm; p < 0.0001 and 3.6 ± 1.24 cm vs 5.4 ± 1.35 cm;p < 0.0001) respectively, a higher relative wall thickness and deceleration time of the early mitral inflow velocity: (0.4 ± 0.12 vs 0.3 ± 0.14 p < 0.0001 and 149.6 ± 72.35 vs 110.9 ± 63.40 p = 0.001) respectively.</p> <p>The two groups with heart failure differed significantly from the control subjects in virtually all echocardiographic measurements except aortic root diameter, LV posterior wall thickness(HFLEF), and late mitral inflow velocity(HFNEF). HFNEF accounted for 70(39.5%) of cases of heart failure in this study.</p> <p>Hypertension is the underlying cardiovascular disease in 134(75.7%) of the combined heart failure population, 58 (82.9%) of the subjects with HFNEF group and 76(71%) of the HFLEF group. Females accounted for 44 (62.9%) of the subjects with HFNEF against 42(39.3%) in the HFLEF group (p = 0.002).</p> <p>Conclusion</p> <p>The frequency of heart failure with normal EF in this native African cohort with heart failure is comparable with the frequency in other populations. These groups of patients are more likely female, hypertensive with concentric pattern of left ventricular hypertrophy.</p
Echocardiographic partition values and prevalence of left ventricular hypertrophy in hypertensive Nigerians
BACKGROUND: Left ventricular hypertrophy (LVH) is a well known independent risk factor for cardiovascular events. It has been shown that combination of left ventricular mass (LVM) and relative wall thickness (RWT) can be used to identify different forms of left ventricular (LV) geometry. Prospective studies have shown that LV geometric patterns have prognostic implications, with the worst prognosis associated with concentric hypertrophy. The methods for the normalization or indexation of LVM have also recently been shown to confer some prognostic value especially in obese population. We sought to determine the prevalence of echocardiographic lLVH using eight different and published cut-off or threshold values in hypertensive subjects seen in a developing country's tertiary centre. METHODS: Echocardiography was performed in four hundred and eighty consecutive hypertensive subjects attending the cardiology clinic of the University college Hospital Ibadan, Nigeria over a two-year period. RESULTS: Complete data was obtained in 457 (95.2%) of the 480 subjects (48.6% women). The prevalence of LVH ranged between 30.9–56.0%. The highest prevalence was when LVM was indexed to the power of 2.7 with a partition value of 49.2 g/ht(2.7 )in men and 46.7 g/ht(2.7 )in women. The lowest prevalence was observed when LVM was indexed to body surface area (BSA) and a partition value of 125 g/m(2 )was used for both sexes. Abnormal LV geometry was present in 61.1%–74.0% of our subjects and commoner in women. CONCLUSION: The prevalence of LVH hypertensive patients is strongly dependent on the cut-off value used to define it. Large-scale prospective study will be needed to determine the prognostic implications of the different LV geometry in native Africans
Endomyocardial Fibrosis: Still a Mystery after 60 Years
The pathologist Jack N. P. Davies identified endomyocardial fibrosis in Uganda in 1947. Since that time, reports of this restrictive cardiomyopathy have come from other parts of tropical Africa, South Asia, and South America. In Kampala, the disease accounts for 20% of heart disease patients referred for echocardiography. We conducted a systematic review of research on the epidemiology and etiology of endomyocardial fibrosis. We relied primarily on articles in the MEDLINE database with either “endomyocardial fibrosis” or “endomyocardial sclerosis” in the title. The volume of publications on endomyocardial fibrosis has declined since the 1980s. Despite several hypotheses regarding cause, no account of the etiology of this disease has yet fully explained its unique geographical distribution
Ethylene glycol oxidation on ternary PtRhNi/C electrocatalyst with different metal compositions
Current trends in the management of chest trauma
No Abstract. Keywords: chest trauma; resuscitation; trauma; trauma careArchives of Ibadan Medicine Vol. 7 (1) 2006: 26-3
Case Report: Post- Traumatic Pseudoanuerysm of the Popliteal Artery
Post-traumatic popliteal pseudoaneurysm (PP) is rare. This is an unusual case of posttraumatic PP associated with severe hemorrhage as a result of glass-cut injury. Our patient had bled repeatedly from the injury, necessitating transfusion with a total of seven pints of blood over a four week period prior to presentation. Duplex ultrasonography established the diagnosis of PP which was confirmed at surgery. This case highlights the significance of duplex ultrasonography in the pre-operative evaluation of patients with vascular trauma, especially in sub-Saharan Africa where computed tomography and digital subtraction angiography may not be readily available or affordable.
Keywords: Pseudoaneurysm (“False Aneurysm”), Trauma, Duplex Ultrasonography Popliteal Arter
Is recombinant activated factor VII effective in the treatment of excessive bleeding after paediatric cardiac surgery?
A best evidence topic in paediatric cardiac surgery was written according to a structured protocol. The question addressed was whether recombinant activated factor VII was effective for the treatment of excessive bleeding after paediatric cardiac surgery. Altogether 150 papers were found using the reported search; 13 papers were identified that provided the best evidence to answer the question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these studies were tabulated. A total of 311 children experienced excessive bleeding following cardiac surgery that was refractory to the conventional methods of achieving haemostasis. One hundred and ninety-two patients received the rFVIIa while 116 were in control arm from five studies. The primary end-point was on chest tube drainage, the plasma prothrombin time, the activated partial thromboplastin time after the administration of rFVIIa and the secondary end-point was reduction of blood products transfusion. Thrombosis was a complication in 8 patients (4.2%); three deaths (1.6%) but not attributable to thromboembolic events following the use of rFVIIa. Most of the studies failed to clearly state the doses but the extracted doses ranged between 30 and 180 µg/kg/dose, the interval between doses ranged between 15 and 120 min with a maximum of four doses. However, most of the patients had 180 µg/kg/dose with interval between dose of 2 h and maximum of two doses with dosage moderated with respect to weight, prior coagulopathy and responsiveness. There were two randomized studies with good sample size. One showed no significant differences in the secondary end points between the two arms and noted no adverse complications. However, the rFVIIa was used prophylactically. The other observed that there were no increase in thromboembolic events rather rFVIIa was effective in decreasing excessive bleeding that may complicate cardiac surgery in children. In conclusion, the studies were in support of the notion that the use of rFVIIa was effective in decreasing excessive bleeding which may complicate paediatric cardiac surgery, and care should be exercised when using it in the children on ECMO circuit
