Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube
The aim of this paper is to fully characterize the new multi-anode
photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective
active area (77%), its pixel size, the low dark signal rate and the capability
to detect single photon signals make this tube suitable for an application in
high energy physics, such as for RICH detectors. Four tubes and two different
bias voltage dividers have been tested. The results of a standard
characterization of the gain and the anode uniformity, the dark signal rate,
the cross-talk and the device behaviour as a function of temperature have been
studied. The behaviour of the tube is studied in a longitudinal magnetic field
up to 100 Gauss. Shields made of a high permeability material are also
investigated. The deterioration of the device performance due to long time
operation at intense light exposure is studied. A quantitative analysis of the
variation of the gain and the dark signals rate due to the aging is described.Comment: 22 page
Estudo do aproveitamento de quatro resíduos agroindustriais para produção de carvão vegetal.
Resumo. Disponível online. MIPE
Large area Si low-temperature light detectors with Neganov-Luke effect
Next generation calorimetric experiments for the search of rare events rely
on the detection of tiny amounts of light (of the order of 20 optical photons)
to discriminate and reduce background sources and improve sensitivity.
Calorimetric detectors are the simplest solution for photon detection at
cryogenic (mK) temperatures. The development of silicon based light detectors
with enhanced performance thanks to the use of the Neganov-Luke effect is
described. The aim of this research line is the production of high performance
detectors with industrial-grade reproducibility and reliability.Comment: 4 pages, 2 figure
Response of microchannel plates to single particles and to electromagnetic showers
We report on the response of microchannel plates (MCPs) to single
relativistic particles and to electromagnetic showers. Particle detection by
means of secondary emission of electrons at the MCP surface has long been
proposed and is used extensively in ion time-of-flight mass spectrometers. What
has not been investigated in depth is their use to detect the ionizing
component of showers. The time resolution of MCPs exceeds anything that has
been previously used in calorimeters and, if exploited effectively, could aid
in the event reconstruction at high luminosity colliders. Several prototypes of
photodetectors with the amplification stage based on MCPs were exposed to
cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The
time resolution and the efficiency of the MCPs are measured as a function of
the particle multiplicity, and the results used to model the response to
high-energy showers.Comment: Paper submitted to NIM
Response of microchannel plates in ionization mode to single particles and electromagnetic showers
Hundreds of concurrent collisions per bunch crossing are expected at future
hadron colliders. Precision timing calorimetry has been advocated as a way to
mitigate the pileup effects and, thanks to their excellent time resolution,
microchannel plates (MCPs) are good candidate detectors for this goal. We
report on the response of MCPs, used as secondary emission detectors, to single
relativistic particles and to electromagnetic showers. Several prototypes, with
different geometries and characteristics, were exposed to particle beams at the
INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency
are measured for single particles and as a function of the multiplicity of
particles. Efficiencies between 50% and 90% to single relativistic particles
are reached, and up to 100% in presence of a large number of particles. Time
resolutions between 20ps and 30ps are obtained.Comment: 20 pages, 9 figures. Paper submitted to NIM
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
We report the results of a search for axions from the 14.4 keV M1 transition
from Fe-57 in the core of the sun using the axio-electric effect in TeO2
bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a
facility used to test bolometers for the CUORE experiment at the Laboratori
Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made
using a newly developed low energy trigger which was optimized to reduce the
detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established
at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the
Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the
flavor-singlet axial vector matrix element. Bounds are given for the interval
0.15 < S < 0.55.Comment: 14 pages, 6 figures, submitted to JCA
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta () decay in Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
decay half-life limits previously reported for CUORE-0,
yr, and in combination with the Cuoricino
limit, yr.Comment: 18 pages, 18 figures. (Version 3 reflects only minor changes to the
text. Few additional details, no major content changes.
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.Comment: 9 pages, 10 figure
- …