14,411 research outputs found
Parallel Temperatures in Supersonic Beams: Ultra Cooling of Light Atoms seeded in a Heavier Carrier Gas
We have found recently that, in a supersonic expansion of a mixture of two
monoatomic gases, the parallel temperatures of the two gases can be very
different. This effect is large if the seeded gas is highly diluted and if its
atomic mass is considerably smaller than the one of the carrier gas. In the
present paper, we present a complete derivation of our theoretical analysis of
this effect. Our calculation is a natural extension of the existing theory of
supersonic cooling to the case of a gas mixture, in the high dilution limit.
Finally, we describe a set of temperature measurements made on a beam of
lithium seeded in argon. Our experimental results are in very good agreement
with the results of our calculation.Comment: 24 novembre 200
Optimization of Single-Sided Charge-Sharing Strip Detectors
Simulation of the charge sharing properties of single-sided CZT strip detectors with small anode pads are presented. The effect of initial event size, carrier repulsion, diffusion, drift, trapping and detrapping are considered. These simulations indicate that such a detector with a 150 µm pitch will provide good charge sharing between neighboring pads. This is supported by a comparison of simulations and measurements for a similar detector with a coarser pitch of 225 µm that could not provide sufficient sharing. The performance of such a detector used as a gamma-ray imager is discussed
Continued Studies of Single-Sided Charge-Sharing CZT Strip Detectors
In this paper, we report progress in the study of thick single-sided charge-sharing cadmium zinc telluride (CZT) strip detector modules designed to perform gammaray spectroscopy and 3-D imaging. We report on continuing laboratory and simulation measurements of prototype detectors with 11×11 unit cells (15×15×7.5mm3 ). We report preliminary measurements of the 3-D spatial resolution. Our studies are aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma measurements while minimizing the number and complexity of the electronic readout channels. This is particularly important in space-based coded aperture and Compton telescope instruments that require large area, large volume detector arrays. Such arrays will be required for the NASA’s Black Hole Finder Probe (BHFP) and Advanced Compton Telescope (ACT). This design requires an anode pattern with contacts whose dimensions and spacing are roughly the size of the ionization charge cloud. The first prototype devices have 125µm anode contacts on 225µm pitch. Our studies conclude that finer pitch contacts will be required to improve imaging efficiency
Further studies of single-sided charge-sharing CZT strip detectors
We report progress in the study of a thick CZT strip detector module designed to perform gamma-ray spectroscopy and 3-D imaging. We report preliminary performance measurements of 7.5 mm thick single-sided charge-sharing strip detector prototype devices. This design features both row and column contacts on the anode surface. This electron-only approach addresses problems associated with poor hole transport in CZT that limit the thickness and energy range of double-sided strip detectors. This work includes laboratory and simulation studies aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma measurements while minimizing the number and complexity of the electronic readout channels. This is particularly important in space-based coded aperture and Compton telescope instruments that require large area, large volume detector arrays. Such arrays will be required for the NASA Black Hole Finder Probe (BHFP)and Advanced Compton Telescope (ACT). This new design requires an anode pattern with contacts whose dimensions and spacing are roughly the size of the ionization charge cloud. The first prototype devices have 125 μm anode contacts on 225 μm pitch. Our results demonstrate the principle of operation but suggest that even finer anode contact feature sizes will be necessary to achieve the desired performance
Single-sided CZT strip detectors
We report progress in the study of thick CZT strip detectors for 3-d imaging and spectroscopy and discuss two approaches to device design. We present the spectroscopic, imaging, detection efficiency and response uniformity performance of prototype devices. Unlike double-sided strip detectors, these devices feature both row and column contacts implemented on the anode surface. This electron-only approach circumvents problems associated with poor hole transport in CZT that normally limit the thickness and energy range of double-sided strip detectors. These devices can achieve similar performance to pixel detectors. The work includes laboratory and simulation studies aimed at developing compact, efficient, detector modules for 0.05 to 1 MeV gamma radiation measurements. The low channel count strip detector approach can significantly reduce the complexity and power requirements of the readout electronics. This is particularly important in space-based coded aperture or Compton telescope instruments requiring large area, large volume detector arrays. Such arrays will be required for NASA\u27s Black Hole Finder Probe (BHFP) and Advanced Compton Telescope (ACT)
Symmetry of Traveling Wave Solutions to the Allen-Cahn Equation in \Er^2
In this paper, we prove even symmetry of monotone traveling wave solutions to
the balanced Allen-Cahn equation in the entire plane. Related results for the
unbalanced Allen-Cahn equation are also discussed
Development of CZT strip detector modules for 0.05- to 1-MeV gamma-ray imaging and spectroscopy
We report progress in our study of cadmium zinc telluride (CZT) strip detectors featuring orthogonal coplanar anode contacts. We specifically report on the performance, characterization and stability of 5 and 10 mm thick prototype CZT detectors fabricated using material from several manufacturers. Our ongoing work includes laboratory and simulation studies aimed at optimizing and developing compact, efficient, high performance detector modules for 0.05 to 1 MeV gamma radiation measurements with space-based instrumentation. The coplanar anode strip configuration retains many of the performance advantages of pixel detectors yet requires far fewer electronic channels to perform both 3-d imaging and spectroscopy. Minimizing the channel count is important for large balloon or space instruments including coded aperture telescopes (such as MARGIE or EXIST) and Compton imaging telescopes (such as TIGRE or ACT). We also present plans for developing compact, space qualified imaging modules designed for integration into closely packed large area detector arrays. We discuss issues associated with detector module and array electronics design and development
Recommended from our members
Comparing the SF-12 and SF-36 Health Status Questionnaires in Patients With and Without Obesity
Objective: To assess how well the SF-36, a well-validated generic quality of life (QOL) instrument, compares with its shorter adaptation, the SF-12, in capturing differences in QOL among patients with and without obesity. Methods: We compared the correlation between the physical (PCS) and mental (MCS) component summary measures of the SF-12 and SF-36 among 356 primary care patients using Pearson coefficients (r) and conducted linear regression models to see how these summary measures captures the variation across BMI. We used model R to assess qualitatively how well each measure explained the variation across BMI. Results: Correlations between SF-12 and SF-36 were higher for the PCS in obese (r = 0.89) compared to overweight (r = 0.73) and normal weight patients (r = 0.75), p < 0.001, but were similar for the MCS across BMI. Compared to normal weight patients, obese patients scored 8.8 points lower on the PCS-12 and 5.7 points lower on the PCS-36 after adjustment for age, sex, and race; the model R was higher with PCS-12 (R = 0.22) than with PCS-36 (R = 0.16). BMI was not significantly associated with either the MCS-12 or MCS-36. Conclusion: The SF-12 correlated highly with SF-36 in obese and non-obese patients and appeared to be a better measure of differences in QOL associated with BMI
Readout and performance of thick CZT strip detectors with orthogonal coplanar anodes
We report progress in the study of CZT strip detectors featuring orthogonal coplanar anode contacts. The work includes laboratory and simulation studies aimed at optimizing and developing compact, efficient, high performance detector modules for 0.05 to 1 MeV gamma radiation measurements. The novel coplanar anode strip configuration retains many of the performance advantages of pixel detectors yet requires far fewer electronic channels to perform both 3-d imaging and spectroscopy. We report on studies aimed at determining an optimum configuration of the analog signal processing electronics to employ with these detectors. We report measurements of energy and spatial resolution in three dimensions for prototype 5 and 10 mm thick CZT detectors using a set of shaping and summing amplifiers
Metaplectic Ice
Spherical Whittaker functions on the metaplectic n-fold cover of GL(r+1) over
a nonarchimedean local field containing n distinct n-th roots of unity may be
expressed as the partition functions of statistical mechanical systems that are
variants of the six-vertex model. If n=1 then in view of the Casselman-Shalika
formula this fact is related to Tokuyama's deformation of the Weyl character
formula. It is shown that various properties of these Whittaker functions may
be expressed in terms of the commutativity of row transfer matrices for the
system. Potentially these properties (which are already proved by other
methods, but very nontrivial) are amenable to proof by the Yang-Baxter
equation
- …
