3,241 research outputs found
Simulation of underground gravity gradients from stochastic seismic fields
We present results obtained from a finite-element simulation of seismic
displacement fields and of gravity gradients generated by those fields. The
displacement field is constructed by a plane wave model with a 3D isotropic
stochastic field and a 2D fundamental Rayleigh field. The plane wave model
provides an accurate representation of stationary fields from distant sources.
Underground gravity gradients are calculated as acceleration of a free test
mass inside a cavity. The results are discussed in the context of
gravity-gradient noise subtraction in third generation gravitational-wave
detectors. Error analysis with respect to the density of the simulated grid
leads to a derivation of an improved seismometer placement inside a 3D array
which would be used in practice to monitor the seismic field.Comment: 24 pages, 12 figure
A comprehensive study of the delay vector variance method for quantification of nonlinearity in dynamical systems
Although vibration monitoring is a popular method to monitor and assess dynamic structures, quantification of linearity or nonlinearity of the dynamic responses remains a challenging problem. We investigate the delay vector variance (DVV) method in this regard in a comprehensive manner to establish the degree to which a change in signal nonlinearity can be related to system nonlinearity and how a change in system parameters affects the nonlinearity in the dynamic response of the system. A wide range of theoretical situations are considered in this regard using a single degree of freedom (SDOF) system to obtain numerical benchmarks. A number of experiments are then carried out using a physical SDOF model in the laboratory. Finally, a composite wind turbine blade is tested for different excitations and the dynamic responses are measured at a number of points to extend the investigation to continuum structures. The dynamic responses were measured using accelerometers, strain gauges and a Laser Doppler vibrometer. This comprehensive study creates a numerical and experimental benchmark for structurally dynamical systems where output-only information is typically available, especially in the context of DVV. The study also allows for comparative analysis between different systems driven by the similar input
Radiation hardness of CMS pixel barrel modules
Pixel detectors are used in the innermost part of the multi purpose
experiments at LHC and are therefore exposed to the highest fluences of
ionising radiation, which in this part of the detectors consists mainly of
charged pions. The radiation hardness of all detector components has thoroughly
been tested up to the fluences expected at the LHC. In case of an LHC upgrade,
the fluence will be much higher and it is not yet clear how long the present
pixel modules will stay operative in such a harsh environment. The aim of this
study was to establish such a limit as a benchmark for other possible detector
concepts considered for the upgrade.
As the sensors and the readout chip are the parts most sensitive to radiation
damage, samples consisting of a small pixel sensor bump-bonded to a CMS-readout
chip (PSI46V2.1) have been irradiated with positive 200 MeV pions at PSI up to
6E14 Neq and with 21 GeV protons at CERN up to 5E15 Neq.
After irradiation the response of the system to beta particles from a Sr-90
source was measured to characterise the charge collection efficiency of the
sensor. Radiation induced changes in the readout chip were also measured. The
results show that the present pixel modules can be expected to be still
operational after a fluence of 2.8E15 Neq. Samples irradiated up to 5E15 Neq
still see the beta particles. However, further tests are needed to confirm
whether a stable operation with high particle detection efficiency is possible
after such a high fluence.Comment: Contribution to the 11th European Symposium on Semiconductor
Detectors June 7-11, 2009 Wildbad Kreuth, German
Gravitational-Wave Stochastic Background from Kinks and Cusps on Cosmic Strings
We compute the contribution of kinks on cosmic string loops to stochastic
background of gravitational waves (SBGW).We find that kinks contribute at the
same order as cusps to the SBGW.We discuss the accessibility of the total
background due to kinks as well as cusps to current and planned gravitational
wave detectors, as well as to the big bang nucleosynthesis (BBN), the cosmic
microwave background (CMB), and pulsar timing constraints. As in the case of
cusps, we find that current data from interferometric gravitational wave
detectors, such as LIGO, are sensitive to areas of parameter space of cosmic
string models complementary to those accessible to pulsar, BBN, and CMB bounds.Comment: 24 pages, 3 figure
Opioid prescribing by multiple providers in Medicare: retrospective observational study of insurance claims
Objectives: To estimate the frequency and characteristics of opioid prescribing by multiple providers in Medicare and the association with hospital admissions related to opioid use. Design: Retrospective cohort study. Setting: Database of prescription drugs and medical claims in 20% random sample of Medicare beneficiaries in 2010. Participants: 1 808 355 Medicare beneficiaries who filled at least one prescription for an opioid from a pharmacy in 2010. Main outcome measures Proportion of beneficiaries who filled opioid prescriptions from multiple providers; proportion of these prescriptions that were concurrently supplied; adjusted rates of hospital admissions related to opioid use associated with multiple provider prescribing. Results: Among 1 208 100 beneficiaries with an opioid prescription, 418 530 (34.6%) filled prescriptions from two providers, 171 420 (14.2%) from three providers, and 143 344 (11.9%) from four or more providers. Among beneficiaries with four or more opioid providers, 110 671 (77.2%) received concurrent opioid prescriptions from multiple providers, and the dominant provider prescribed less than half of the mean total prescriptions per beneficiary (7.9/15.2 prescriptions). Multiple provider prescribing was highest among beneficiaries who were also prescribed stimulants, non-narcotic analgesics, and central nervous system, neuromuscular, and antineoplastic drugs. Hospital admissions related to opioid use increased with multiple provider prescribing: the annual unadjusted rate of admission was 1.63% (95% confidence interval 1.58 to 1.67%) for beneficiaries with one provider, 2.08% (2.03% to 2.14%) for two providers, 2.87% (2.77% to 2.97%) for three providers, and 4.83% (4.70% to 4.96%) for four or more providers. Results were similar after covariate adjustment. Conclusions: Concurrent opioid prescribing by multiple providers is common in Medicare patients and is associated with higher rates of hospital admission related to opioid use
CDMS, Supersymmetry and Extra Dimensions
The CDMS experiment aims to directly detect massive, cold dark matter
particles originating from the Milky Way halo. Charge and lattice excitations
are detected after a particle scatters in a Ge or Si crystal kept at ~30 mK,
allowing to separate nuclear recoils from the dominating electromagnetic
background. The operation of 12 detectors in the Soudan mine for 75 live days
in 2004 delivered no evidence for a signal, yielding stringent limits on dark
matter candidates from supersymmetry and universal extra dimensions. Thirty Ge
and Si detectors are presently installed in the Soudan cryostat, and operating
at base temperature. The run scheduled to start in 2006 is expected to yield a
one order of magnitude increase in dark matter sensitivity.Comment: To be published in the proceedings of the 7th UCLA symposium on
sources and detection of dark matter and dark energy in the universe, Marina
del Rey, Feb 22-24, 200
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.Comment: 4 pages, 3 figure
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
We report the result of a blinded search for Weakly Interacting Massive
Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an
exposure of 1690 kg days, a single candidate event is observed, consistent with
expected backgrounds. This analysis (combined with previous Ge results) sets an
upper limit on the spin-independent WIMP--nucleon cross section of () cm at 46 GeV/. These results set the
strongest limits for WIMP--germanium-nucleus interactions for masses 12
GeV/
Upper Limits on a Stochastic Background of Gravitational Waves
The Laser Interferometer Gravitational-Wave Observatory has performed a third science run with much improved sensitivities of all three interferometers. We present an analysis of approximately 200 hours of data acquired during this run, used to search for a stochastic background of gravitational radiation. We place upper bounds on the energy density stored as gravitational radiation for three different spectral power laws. For the flat spectrum, our limit of Ω_0<8.4×10^(-4) in the 69–156 Hz band is ~10^5 times lower than the previous result in this frequency range
- …
