881 research outputs found

    A 3-D Track-Finding Processor for the CMS Level-1 Muon Trigger

    Full text link
    We report on the design and test results of a prototype processor for the CMS Level-1 trigger that performs 3-D track reconstruction and measurement from data recorded by the cathode strip chambers of the endcap muon system. The tracking algorithms are written in C++ using a class library we developed that facilitates automatic conversion to Verilog. The code is synthesized into firmware for field-programmable gate-arrays from the Xilinx Virtex-II series. A second-generation prototype has been developed and is currently under test. It performs regional track-finding in a 60 degree azimuthal sector and accepts 3 GB/s of input data synchronously with the 40 MHz beam crossing frequency. The latency of the track-finding algorithms is expected to be 250 ns, including geometrical alignment correction of incoming track segments and a final momentum assignment based on the muon trajectory in the non-uniform magnetic field in the CMS endcaps.Comment: 7 pages, 5 figures, proceedings for the conference on Computing in High Energy and Nuclear Physics, March 24-28 2003, La Jolla, Californi

    SUSY Survey with Inclusive Muon and Same-Sign Dimuon Accompanied by Jets and MET with CMS

    Get PDF
    Generic signatures of supersymmetry with R-parity conservation include those of single isolated muons or like-sign isolated dimuon pairs, accompanied with energetic jets and missing transverse energy. The ability of CMS to discover supersymmetry with these signals is estimated for 10 fb^{-1} of data collected with the inclusive single-muon and dimuon High-Level-Trigger paths. The selection criteria are optimized and the systematic effects are studied for a single low-mass benchmark point of the constrained MSSM with m_0 = 60,GeV/c^2, m_{1/2} = 250,GeVc^2, tan beta=10, A_0=0 and mu> 0. Discovery contours in the m_0, m_{1/2}) plane are presented for integrated luminosities ranging from 1 to 100, fb^{-1}

    The CMS Modular Track Finder boards, MTF6 and MTF7

    Get PDF
    To accommodate the increase in energy and luminosity of the upgraded LHC, the CMS Endcap Muon Level 1 Trigger system has to be significantly modified. To provide the best track reconstruction, the Trigger system must now import all available trigger primitives generated by Cathode Strip Chambers and by other regional subsystems, such as Resistive Plate Chambers. In addition to massive input bandwidth, this also requires a significant increase in logic and memory resources. To satisfy these requirements, a new Sector Processor unit for muon track finding is being designed. This unit follows the micro-TCA standard recently adopted by CMS. It consists of three modules. The Core Logic module houses the large FPGA that contains the processing logic and multi-gigabit serial links for data exchange. The Optical module contains optical receivers and transmitters; it communicates with the Core Logic module via a custom backplane section. The Look-Up Table module contains a large amount of low-latency memory that is used to assign the final transverse momentum of the muon candidate tracks. The name of the unit — Modular Track Finder — reflects the modular approach used in the design. Presented here are the details of the hardware design of the prototype unit based on Xilinx's Virtex-6 FPGA family, MTF6, as well as results of the conducted tests. Also presented are plans for the pre-production prototype based on the Virtex-7 FPGA family, MTF7

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore