2,478 research outputs found

    Summary report: A preliminary investigation into the use of fuzzy logic for the control of redundant manipulators

    Get PDF
    The Rice University Department of Mechanical Engineering and Materials Sciences' Robotics Group designed and built an eight degree of freedom redundant manipulator. Fuzzy logic was proposed as a control scheme for tasks not directly controlled by a human operator. In preliminary work, fuzzy logic control was implemented for a camera tracking system and a six degree of freedom manipulator. Both preliminary systems use real time vision data as input to fuzzy controllers. Related projects include integration of tactile sensing and fuzzy control of a redundant snake-like arm that is under construction

    A multi-sensor system for robotics proximity operations

    Get PDF
    Robots without sensors can perform only simple repetitive tasks and cannot cope with unplanned events. A multi-sensor system is needed for a robot to locate a target, move into its neighborhood and perform operations in contact with the object. Systems that can be used for such tasks are described

    Multiple cyclotron line-forming regions in GX 301-2

    Get PDF
    We present two observations of the high-mass X-ray binary GX 301-2 with NuSTAR, taken at different orbital phases and different luminosities. We find that the continuum is well described by typical phenomenological models, like a very strongly absorbed NPEX model. However, for a statistically acceptable description of the hard X-ray spectrum we require two cyclotron resonant scattering features (CRSF), one at ~35 keV and the other at ~50 keV. Even though both features strongly overlap, the good resolution and sensitivity of NuSTAR allows us to disentangle them at >=99.9% significance. This is the first time that two CRSFs are seen in GX 301-2. We find that the CRSFs are very likely independently formed, as their energies are not harmonically related and, if it were a single line, the deviation from a Gaussian shape would be very large. We compare our results to archival Suzaku data and find that our model also provides a good fit to those data. We study the behavior of the continuum as well as the CRSF parameters as function of pulse phase in seven phase bins. We find that the energy of the 35 keV CRSF varies smoothly as function of phase, between 30-38 keV. To explain this variation, we apply a simple model of the accretion column, taking the altitude of the line-forming region, the velocity of the in-falling material, and the resulting relativistic effects into account. We find that in this model the observed energy variation can be explained simply due to a variation of the projected velocity and beaming factor of the line forming region towards us.Comment: 18 pages, 10 figures, accepted for publication in A&

    Spectral and Timing Analysis of the accretion-powered pulsar 4U 1626-67 observed with Suzaku and NuSTAR

    Get PDF
    We present an analysis of the spectral shape and pulse profile of the accretion-powered pulsar 4U 1626-67 observed with Suzaku and NuSTAR during a spin-up state. The pulsar, which experienced a torque reversal to spin-up in 2008, has a spin period of 7.7 s. Comparing the phase-averaged spectra obtained with Suzaku in 2010 and with NuSTAR in 2015, we find that the spectral shape changed between the two observations: the 3-10 keV flux increased by 5% while the 30-60 keV flux decreased significantly by 35%. Phase-averaged and phase-resolved spectral analysis shows that the continuum spectrum observed by NuSTAR is well described by an empirical NPEX continuum with an added broad Gaussian emission component around the spectral peak at 20 keV. Taken together with the observed Pdot value obtained from Fermi/GBM, we conclude that the spectral change between the Suzaku and NuSTAR observations was likely caused by an increase of the accretion rate. We also report the possible detection of asymmetry in the profile of the fundamental cyclotron line. Furthermore, we present a study of the energy-resolved pulse profiles using a new relativistic ray tracing code, where we perform a simultaneous fit to the pulse profiles assuming a two-column geometry with a mixed pencil- and fan-beam emission pattern. The resulting pulse profile decompositions enable us to obtain geometrical parameters of accretion columns (inclination, azimuthal and polar angles) and a fiducial set of beam patterns. This information is important to validate the theoretical predictions from radiation transfer in a strong magnetic field.Comment: 19 pages, 14 figures, Accepted for publication in ApJ on May 5, 201

    Cyclotron resonant scattering feature simulations. I. Thermally averaged cyclotron scattering cross sections, mean free photon-path tables, and electron momentum sampling

    Get PDF
    Electron cyclotron resonant scattering features (CRSFs) are observed as absorption-like lines in the spectra of X-ray pulsars. A significant fraction of the computing time for Monte Carlo simulations of these quantum mechanical features is spent on the calculation of the mean free path for each individual photon before scattering, since it involves a complex numerical integration over the scattering cross section and the (thermal) velocity distribution of the scattering electrons. We aim to numerically calculate interpolation tables which can be used in CRSF simulations to sample the mean free path of the scattering photon and the momentum of the scattering electron. The tables also contain all the information required for sampling the scattering electron's final spin. The tables were calculated using an adaptive Simpson integration scheme. The energy and angle grids were refined until a prescribed accuracy is reached. The tables are used by our simulation code to produce artificial CRSF spectra. The electron momenta sampled during these simulations were analyzed and justified using theoretically determined boundaries. We present a complete set of tables suited for mean free path calculations of Monte Carlo simulations of the cyclotron scattering process for conditions expected in typical X-ray pulsar accretion columns (0.01<B/B_{crit}<=0.12, where B_{crit}=4.413x10^{13} G and 3keV<=kT<15keV). The sampling of the tables is chosen such that the results have an estimated relative error of at most 1/15 for all points in the grid. The tables are available online at http://www.sternwarte.uni-erlangen.de/research/cyclo.Comment: A&A, in pres

    Prospective Study Examining Clinical Outcomes Associated with a Negative Pressure Wound Therapy System and Barker’s Vacuum Packing Technique

    Get PDF
    Background The open abdomen has become a common procedure in the management of complex abdominal problems and has improved patient survival. The method of temporary abdominal closure (TAC) may play a role in patient outcome. Methods A prospective, observational, open-label study was performed to evaluate two TAC techniques in surgical and trauma patients requiring open abdomen management: Barker’s vacuum-packing technique (BVPT) and the ABTheraTM open abdomen negative pressure therapy system (NPWT). Study endpoints were days to and rate of 30-day primary fascial closure (PFC) and 30-day all-cause mortality. Results Altogether, 280 patients were enrolled from 20 study sites. Among them, 168 patients underwent at least 48 hours of consistent TAC therapy (111 NPWT, 57 BVPT). The two study groups were well matched demographically. Median days to PFC were 9 days for NPWT versus 12 days for BVPT (p = 0.12). The 30-day PFC rate was 69 % for NPWT and 51 % for BVPT (p = 0.03). The 30-day all-cause mortality was 14 % for NPWT and 30 % for BVPT (p = 0.01). Multivariate logistic regression analysis identified that patients treated with NPWT were significantly more likely to survive than the BVPT patients [odds ratio 3.17 (95 % confidence interval 1.22–8.26); p = 0.02] after controlling for age, severity of illness, and cumulative fluid administration. Conclusions Active NPWT is associated with significantly higher 30-day PFC rates and lower 30-day all-cause mortality among patients who require an open abdomen for at least 48 h during treatment for critical illness
    corecore