36 research outputs found
Topological (Sliced) Doping of a 3D Peierls System: Predicted Structure of Doped BaBiO3
At hole concentrations below x=0.4, Ba_(1-x)K_xBiO_3 is non-metallic. At x=0,
pure BaBiO3 is a Peierls insulator. Very dilute holes create bipolaronic point
defects in the Peierls order parameter. Here we find that the Rice-Sneddon
version of Peierls theory predicts that more concentrated holes should form
stacking faults (two-dimensional topological defects, called slices) in the
Peierls order parameter. However, the long-range Coulomb interaction, left out
of the Rice-Sneddon model, destabilizes slices in favor of point bipolarons at
low concentrations, leaving a window near 30% doping where the sliced state is
marginally stable.Comment: 6 pages with 5 embedded postscript figure
Clinical Significance of Exercise Pulmonary Hypertension With a Negative Diastolic Stress Test for Suspected Heart Failure With Preserved Ejection Fraction
BACKGROUND: Half of patients with heart failure with preserved ejection fraction (HFpEF) remain undiagnosed by resting evaluation alone. Therefore, exercise testing is proposed. The diastolic stress test (DST), however, has limited sensitivity. We aimed to determine the clinical significance of adding the mean pulmonary artery pressure over cardiac output (mPAP/CO) slope to the DST in suspected HFpEF. METHODS AND RESULTS: In this prospective cohort study, consecutive patients (n=1936) with suspected HFpEF underwent exercise echocardiography with simultaneous respiratory gas analysis. These patients were stratified by exercise E over e′ (exE/e′) and mPAP/CO slope, and peak oxygen uptake, natriuretic peptides (NT-proBNP [N-terminal pro-B-type natriuretic peptide]), and score-based HFpEF likelihood were compared. Twenty-two percent of patients (n=428) had exE/e′<15 despite a mPAP/CO slope>3 mm Hg/L per min, 24% (n=464) had a positive DST (exE/e′≥15), and 54% (n=1044) had a normal DST and slope. Percentage of predicted oxygen uptake was similar in the group with exE/e′<15 but high mPAP/CO slope and the positive DST group (−2% [−5% to +1%]), yet worse than in those with normal DST and slope (−12% [−14% to −9%]). Patients with exE/e′<15 but a high slope had NT-proBNP levels and H 2 FPEF (heavy, hypertensive, atrial fibrillation, pulmonary hypertension, elder; filling pressure) scores intermediate to the positive DST group and the group with both a normal DST and slope. CONCLUSIONS: Twenty-two percent of patients with suspected HFpEF presented with a mPAP/CO slope>3 mm Hg/L per min despite a negative DST. These patients had HFpEF characteristics and a peak oxygen uptake as low as patients with a positive DST. Therefore, an elevated mPAP/CO slope might indicate HFpEF irrespective of the DST result.</p
An absolute measurement of the neutron production rate of a spent nuclear fuel sample used for depletion code validation
A method to determine the neutron production rate of a spent nuclear fuel segment sample by means of non-destructive assay conducted under standard controlled-area conditions is described and demonstrated. A neutron well counter designed for routine nuclear safeguards applications is applied. The method relies on a transfer procedure that is adapted to the hot cell facilities at the Laboratory for High and Medium level Activity of SCK CEN in Belgium. Experiments with 252Cf(sf) sources, certified for their neutron emission rate, were carried out at the Joint Research Centre to determine the characteristics of the detection device. Measurements of a segment of a spent nuclear fuel rod were carried out at SCK CEN resulting in an absolute and non-destructive measurement of the neutron production rate avoiding any reference to a representative spent nuclear fuel sample to calibrate the device. Results of these measurements were used to study the performance of depletion codes, i.e., ALEPH2, SCALE, and Serpent2. The study includes a code-to-code and code-to-experiment comparison using different nuclear data libraries
Semaglutide and cardiovascular outcomes in patients with obesity and prevalent heart failure: a prespecified analysis of the SELECT trial
Background: Semaglutide, a GLP-1 receptor agonist, reduces the risk of major adverse cardiovascular events (MACE) in people with overweight or obesity, but the effects of this drug on outcomes in patients with atherosclerotic cardiovascular disease and heart failure are unknown. We report a prespecified analysis of the effect of once-weekly subcutaneous semaglutide 2·4 mg on ischaemic and heart failure cardiovascular outcomes. We aimed to investigate if semaglutide was beneficial in patients with atherosclerotic cardiovascular disease with a history of heart failure compared with placebo; if there was a difference in outcome in patients designated as having heart failure with preserved ejection fraction compared with heart failure with reduced ejection fraction; and if the efficacy and safety of semaglutide in patients with heart failure was related to baseline characteristics or subtype of heart failure. Methods: The SELECT trial was a randomised, double-blind, multicentre, placebo-controlled, event-driven phase 3 trial in 41 countries. Adults aged 45 years and older, with a BMI of 27 kg/m2 or greater and established cardiovascular disease were eligible for the study. Patients were randomly assigned (1:1) with a block size of four using an interactive web response system in a double-blind manner to escalating doses of once-weekly subcutaneous semaglutide over 16 weeks to a target dose of 2·4 mg, or placebo. In a prespecified analysis, we examined the effect of semaglutide compared with placebo in patients with and without a history of heart failure at enrolment, subclassified as heart failure with preserved ejection fraction, heart failure with reduced ejection fraction, or unclassified heart failure. Endpoints comprised MACE (a composite of non-fatal myocardial infarction, non-fatal stroke, and cardiovascular death); a composite heart failure outcome (cardiovascular death or hospitalisation or urgent hospital visit for heart failure); cardiovascular death; and all-cause death. The study is registered with ClinicalTrials.gov, NCT03574597. Findings: Between Oct 31, 2018, and March 31, 2021, 17 604 patients with a mean age of 61·6 years (SD 8·9) and a mean BMI of 33·4 kg/m2 (5·0) were randomly assigned to receive semaglutide (8803 [50·0%] patients) or placebo (8801 [50·0%] patients). 4286 (24·3%) of 17 604 patients had a history of investigator-defined heart failure at enrolment: 2273 (53·0%) of 4286 patients had heart failure with preserved ejection fraction, 1347 (31·4%) had heart failure with reduced ejection fraction, and 666 (15·5%) had unclassified heart failure. Baseline characteristics were similar between patients with and without heart failure. Patients with heart failure had a higher incidence of clinical events. Semaglutide improved all outcome measures in patients with heart failure at random assignment compared with those without heart failure (hazard ratio [HR] 0·72, 95% CI 0·60-0·87 for MACE; 0·79, 0·64-0·98 for the heart failure composite endpoint; 0·76, 0·59-0·97 for cardiovascular death; and 0·81, 0·66-1·00 for all-cause death; all pinteraction>0·19). Treatment with semaglutide resulted in improved outcomes in both the heart failure with reduced ejection fraction (HR 0·65, 95% CI 0·49-0·87 for MACE; 0·79, 0·58-1·08 for the composite heart failure endpoint) and heart failure with preserved ejection fraction groups (0·69, 0·51-0·91 for MACE; 0·75, 0·52-1·07 for the composite heart failure endpoint), although patients with heart failure with reduced ejection fraction had higher absolute event rates than those with heart failure with preserved ejection fraction. For MACE and the heart failure composite, there were no significant differences in benefits across baseline age, sex, BMI, New York Heart Association status, and diuretic use. Serious adverse events were less frequent with semaglutide versus placebo, regardless of heart failure subtype. Interpretation: In patients with atherosclerotic cardiovascular diease and overweight or obesity, treatment with semaglutide 2·4 mg reduced MACE and composite heart failure endpoints compared with placebo in those with and without clinical heart failure, regardless of heart failure subtype. Our findings could facilitate prescribing and result in improved clinical outcomes for this patient group. Funding: Novo Nordisk
A new Method for the Prediction of the Side Force on Keel and Rudder of a Sailing Yacht based on the Results of the Delft Systematic Yacht Hull Series
Study of the Pyrochlore-Related Structure of α-Cs2U4O12 by Powder Neutron and X-Ray Diffraction.
International audienc
X-Ray Photoelectron Spectroscopy on Uranium Oxides. A Comparison between Bulk and Thin Layers.
Abstract not availableJRC.E-Institute for Transuranium Elements (Karlsruhe
Study of the pyrochlore-related structure of α-Cs2U4O12 by powder neutron and X-ray diffraction
International audienc
