4,687 research outputs found

    Aplicação do método AID estendido na identificação de linhagens de frangos resistentes a coccidiosis (Eimeria tenella).

    Get PDF
    O objetivo foi analisar dados de pesagens (y) de bovinos. De cada animal foram feitas nove pesagens do nascimento aos dois anos de idade. A variável y foi transformada por yl = (yl-1)/l (l 1 0), a qual foi eficiente na redução dos coeficientes de assimetria e da heterogeneidade de variância dos dados

    High-resolution tracking in a GEM-Emulsion detector

    Full text link
    SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic fiel

    Σp\Sigma^- p emission rates in KK^- absorptions at rest on 6^6Li, 7^7Li, 9^{9}Be, 13^{13}C and 16^{16}O

    Full text link
    An experimental study of the KstopAΣpAK^-_{stop}A\rightarrow \Sigma^- p A' reaction on A=6A=^6Li, 7^7Li, 9^9Be, 13^{13}C and 16^{16}O pp-shell nuclei is presented. The data were collected by the FINUDA spectrometer operating at the DAΦ\PhiNE ϕ\phi-factory (LNF-INFN, Italy). Emission rates for the reaction in the mentioned nuclei are measured and compared with the few existing data. The spectra of several observables are discussed; indications of Quasi-Free absorptions by a (np)(np) pair embedded in the AA nucleus can be obtained from the study of the missing mass distributions.Comment: Version accepted by PR

    Improved Experimental Limits on the Production of Magnetic Monopoles

    Get PDF
    We present new limits on low mass accelerator-produced point-like Dirac magnetic monopoles trapped and bound in matter surrounding the D\O collision region of the Tevatron at Fermilab (experiment E-882). In the context of a Drell-Yan mechanism, we obtain cross section limits for the production of monopoles with magnetic charge values of 1, 2, 3, and 6 times the minimum Dirac charge of the order of picobarns, some hundred times smaller than found in similar previous Fermilab searches. Mass limits inferred from these cross section limits are presented.Comment: 5 pages, 4 eps figures, REVTe

    Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    Get PDF
    The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.Comment: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 200

    A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP

    Full text link
    The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the {\mu}TPC and analog readout, with time and charge measurements will allow to reach the 130 {\mu}m spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field
    corecore