136 research outputs found
Are There Age Spreads in Star Forming Regions?
A luminosity spread at a given effective temperature is ubiquitously seen in
the Hertzsprung-Russell (HR) diagrams of young star forming regions and often
interpreted in terms of a prolonged period (>=10 Myr) of star formation. I
review the evidence that the observed luminosity spreads are genuine and not
caused by astrophysical sources of scatter. I then address whether the
luminosity spreads necessarily imply large age spreads, by comparing HR diagram
ages with ages from independent clocks such as stellar rotation rate, the
presence of circumstellar material and lithium depletion. I argue that whilst
there probably is a true luminosity dispersion, there is little evidence to
support age spreads larger than a few Myr. This paradox could be resolved by
brief periods of rapid accretion during the class I pre main-sequence phase.Comment: To appear in the proceedings of JENAM10: Star Clusters in the Era of
Large Surveys, 8 page
Community led active schools programme (CLASP) exploring the implementation of health interventions in primary schools: headteachers’ perspectives
Background: Schools are repeatedly utilised as a key setting for health interventions. However, the translation of effective research findings to the school setting can be problematic. In order to improve effective translation of future interventions, it is imperative key challenges and facilitators of implementing health interventions be understood from a school's perspective. Methods: Nineteen semi-structured interviews were conducted in primary schools (headteachers n = 16, deputy headteacher n = 1, healthy school co-ordinator n = 2). Interviews were transcribed verbatim and analysed using thematic analysis. Results: The main challenges for schools in implementing health interventions were; government-led academic priorities, initiative overload, low autonomy for schools, lack of staff support, lack of facilities and resources, litigation risk and parental engagement. Recommendations to increase the application of interventions into the school setting included; better planning and organisation, greater collaboration with schools and external partners and elements addressing sustainability. Child-centred and cross-curricular approaches, inclusive whole school approaches and assurances to be supportive of the school ethos were also favoured for consideration. Conclusions: This work explores schools' perspectives regarding the implementation of health interventions and utilises these thoughts to create guidelines for developing future school-based interventions. Recommendations include the need to account for variability between school environments, staff and pupils. Interventions with an element of adaptability were preferred over the delivery of blanket fixed interventions. Involving schools in the developmental stage would add useful insights to ensure the interventions can be tailored to best suit each individual schools' needs and improve implementation.11 page(s
Managing depression in people with multimorbidity: a qualitative evaluation of an integrated collaborative care model
Dentifrices, mouthwashes, and remineralization/caries arrestment strategies
While our knowledge of the dental caries process and its prevention has greatly advanced over the past fifty years, it is fair to state that the management of this disease at the level of the individual patient remains largely empirical. Recommendations for fluoride use by patients at different levels of caries risk are mainly based on the adage that more is better. There is a general understanding that the fluoride compound, concentration, frequency of use, duration of exposure, and method of delivery can influence fluoride efficacy. Two important factors are (1) the initial interaction of relatively high concentrations of fluoride with the tooth surface and plaque during application and (2) the retention of fluoride in oral fluids after application
Fast and flexible analysis of direct dark matter search data with machine learning
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture nonlinear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs, such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable
Effective field theory analysis of the first LUX dark matter search
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6×10-46 cm2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4×104 kg·day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass
Improved Modeling of β Electronic Recoils in Liquid Xenon Using LUX Calibration Data
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the decays of H and C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction
Investigation of background electron emission in the LUX detector
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments
Search for two neutrino double electron capture of ¹²⁴Xe and ¹²⁶Xe in the full exposure of the LUX detector
Two-neutrino double electron capture is a process allowed in the standard model of particle physics. This rare decay has been observed in 78Kr, 130Ba and more recently in 124Xe. In this publication we report on the search for this process in 124Xe and 126Xe using the full exposure of the large underground xenon (LUX) experiment, in a total of 27769.5 kg-days. No evidence of a signal was observed, allowing us to set 90% C.L. lower limits for the half-lives of these decays of 2.0 × 1021 years for 124Xe and 1.9 × 1021 years for 126Xe
First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data
We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live-days × 118 kg. Here, the calculations of the mirror electron scattering rate in liquid xenon take into account the shielding effects from mirror dark matter captured within the Earth. Annual and diurnal modulation of the dark matter flux and atomic shell effects in xenon are also accounted for. Having found no evidence for an electron recoil signal induced by mirror dark matter interactions we place an upper limit on the kinetic mixing parameter over a range of local mirror electron temperatures between 0.1 and 0.6 keV. This limit shows significant improvement over the previous experimental constraint from orthopositronium decays and significantly reduces the allowed parameter space for the model. We exclude mirror electron temperatures above 0.3 keV at a 90% confidence level, for this model, and constrain the kinetic mixing below this temperature
- …
