A new automated and putatively versatile synthesis of the PSMA-ligand derivative [18F]DCFPyL using the FASTlabTM synthesizer.
BACKGROUND
Noninvasive molecular imaging using peptides and biomolecules labelled with positron emitters has become important for detection of cancer and other diseases with PET (positron emission tomography). The positron emitting radionuclide fluorine-18 is widely available in high yield from cyclotrons and has favorable decay (t1/2 109.7 min) and imaging properties. 18F-Labelling of biomolecules and peptides for use as radiotracers is customarily achieved in a two-step approach, which can be challenging to automate. 6-[18F]Fluoronicotinic acid 2,3,5,6-tetrafluorophenyl ester ([18F]F-Py-TFP) is a versatile 18F-prosthetic group for this purpose, which can be rapidly be produced in an one-step approach on solid support. This work details an automated procedure on the cassette-based GE FASTlab™ platform for the labeling of a peptidomimetic, exemplified by the case of using the Glu-CO-Lys motif to produce [18F]DCFPyL, a ligand targeting the prostate specific membrane antigen (PSMA).
RESULTS
From fluorine-18 delivery a fully automated two-step radiosynthesis of [18F]DCFPyL was completed in 56 min with an overall end of synthesis yield as high as 37% using solid phase extraction (SPE) purification on the GE FASTlab™ platform.
CONCLUSIONS
Putatively, this radiolabeling methodology is inherently amenable to automation with a diverse set of synthesis modules, and it should generalize for production of a broad spectrum of biomolecule-based radiotracers for use in PET imaging
Parametric Study of a Taut Compliant Mooring System for a FOWT Compared to a Catenary Mooring
The catenary mooring system is a well recognized station keeping method. However, there could be economical and environmental benefits of reducing the footprint. In the last decades, more focus has been given to synthetic mooring lines and different mooring layouts to optimize the levelized cost of energy (LCOE) for offshore renevable energy converters such as wave energy converters. Therefore, this work presents a parametric study of two important parameters, namely the mooring line angle and line pretension, for a taut mooring configuration focusing on the dynamic response when applied to the TetraSpar floating foundation compared to a catenary mooring system. The work is based on experimental results conducted in the wave basin at Aalborg University (AAU) and compared to analytical stiffness calculations. In addition, a numerical model was tuned based on the main dynamics to achieve the tension response. The results showed satisfying dynamic behavior where the angle and pretension mainly influenced the surge and yaw natural periods. The motion response showed similar behavior between the chosen parameters, and larger pitch amplitudes were found compared to the catenary system
Quantitative Determination of Fibrinogen of Patients with Coronary Heart Diseases through Piezoelectric Agglutination Sensor
Fibrinogen can transform fibrin through an agglutination reaction, finally forming fibrin polymer with grid structure. The density and viscosity of the reaction system changes drastically during the course of agglutination. In this research, we apply an independently-developed piezoelectric agglutination sensor to detect the fibrinogen agglutination reaction in patients with coronary heart diseases. The terminal judgment method of determining plasma agglutination reaction through piezoelectric agglutination sensor was established. In addition, the standard curve between plasma agglutination time and fibrinogen concentration was established to determinate fibrinogen content quantitatively. The results indicate the close correlation between the STAGO paramagnetic particle method and the method of piezoelectric agglutination sensor for the detection of Fibrinogen. The correlation coefficient was 0.91 (γ = 0.91). The determination can be completed within 10 minutes. The fibrinogen concentration in the coronary heart disease group was significantly higher than that of the healthy control group (P < 0.05). The results reveal that high fibrinogen concentration is closely correlated to the incurrence, development and prognosis of coronary heart diseases. Compared with other traditional methods, the method of piezoelectric agglutination sensor has some merits such as operation convenience, small size, low cost, quick detecting, good precision and the common reacting agents with paramagnetic particle method
Molecular imaging of angiogenesis with SPECT
Single-photon emission computed tomography (SPECT) and position emission tomography (PET) are the two main imaging modalities in nuclear medicine. SPECT imaging is more widely available than PET imaging and the radionuclides used for SPECT are easier to prepare and usually have a longer half-life than those used for PET. In addition, SPECT is a less expensive technique than PET. Commonly used gamma emitters are: 99mTc (Emax 141 keV, T1/2 6.02 h), 123I (Emax 529 keV, T1/2 13.0 h) and 111In (Emax 245 keV, T1/2 67.2 h). Compared to clinical SPECT, PET has a higher spatial resolution and the possibility to more accurately estimate the in vivo concentration of a tracer. In preclinical imaging, the situation is quite different. The resolution of microSPECT cameras (<0.5 mm) is higher than that of microPET cameras (>1.5 mm). In this report, studies on new radiolabelled tracers for SPECT imaging of angiogenesis in tumours are reviewed
Early molecular imaging of interstitial changes in patients after myocardial infarction: Comparison with delayed contrast-enhanced magnetic resonance imaging
18F-Fluciclovine PET/CT performance in biochemical recurrence of prostate cancer: a systematic review
Background
A systematic literature review of the performance of 18Fluorine-fluciclovine PET/CT for imaging of men with recurrent prostate cancer was performed.
Methods
Scientific literature databases (MEDLINE, ScienceDirect and Cochrane Libraries) were searched systematically during Oct 2020 using PRISMA criteria. No limit was put on the date of publication. Prospective studies reporting a patient-level 18F-fluciclovine detection rate (DR) from ≥25 patients with recurrent prostate cancer were sought. Proceedings of relevant meetings held from 2018 through Oct 2020 were searched for abstracts meeting criteria.
Results
Searches identified 321 unique articles. In total, nine articles (six papers and three conference abstracts), comprising a total of 850 patients met inclusion criteria. Most studies (n = 6) relied on ASTRO-Phoenix Criteria, EAU-ESTRO-SIOG, and/or ASTRO-AUA guidelines to identify patients with biochemical recurrence. Patients’ PSA levels ranged from 0.02–301.7 ng/mL (median level per study, 0.34–4.10 ng/mL [n = 8]). Approximately 64% of patients had undergone prostatectomy, but three studies focused solely on post-prostatectomy patients. Adherence to imaging protocol guidelines was heterogeneous, with variance seen in administered activity, uptake and scan times. Overall patient-level DR varied between studies from 26% to 83%, with 78% of studies reporting a DR > 50%. DR was proportional to PSA, but even at PSA < 0.5 ng/mL DR of up to 53% were reported. Prostate/bed DR (n = 7) ranged from 18% to 78% and extra-prostatic rates (n = 6) from 8% to 72%. Pelvic node and bone lesion DR ranged from 8% to 47% and 0% to 26%, respectively (n = 5). 18F-Fluciclovine PET/CT was shown to impact patient management and outcomes. Two studies reported 59–63% of patients to have a management change post-scan. A further study showed significant increase in failure-free survival following 18F-fluciclovine-guided compared with conventional imaging-guided radiotherapy planning.
Conclusions
18F-Fluciclovine PET/CT shows good performance in patients with recurrent prostate cancer leading to measurable clinical benefits. Careful adherence to recommended imaging protocols may help optimize DR
- …