1,312 research outputs found

    Percolation of strings and the first RHIC data on multiplicity and tranverse momentum distributions

    Get PDF
    The dependence of the multiplicity on the number of collisions and the transverse momentum distribution for central and peripheral Au-Au collisions are studied in the model of percolation of strings relative to the experimental conditions at RHIC. The comparison with the first RHIC data shows a good agreement.Comment: RevTeX, 11 pages, 4 eps figures included using epsfi

    D3-D7 Quark-Gluon Plasmas at Finite Baryon Density

    Get PDF
    We present the string dual to SU(Nc) N=4 SYM, coupled to Nf massless fundamental flavors, at finite temperature and baryon density. The solution is determined by two dimensionless parameters, both depending on the 't Hooft coupling λh\lambda_h at the scale set by the temperature T: ϵhλhNf/Nc\epsilon_h\sim\lambda_h Nf/Nc, weighting the backreaction of the flavor fields and δ~λh1/2nb/(NfT3)\tilde\delta\sim\lambda_h^{-1/2}nb/(Nf T^3), where nbnb is the baryon density. For small values of these two parameters the solution is given analytically up to second order. We study the thermodynamics of the system in the canonical and grand-canonical ensembles. We then analyze the energy loss of partons moving through the plasma, computing the jet quenching parameter and studying its dependence on the baryon density. Finally, we analyze certain "optical" properties of the plasma. The whole setup is generalized to non abelian strongly coupled plasmas engineered on D3-D7 systems with D3-branes placed at the tip of a generic singular Calabi-Yau cone. In all the cases, fundamental matter fields are introduced by means of homogeneously smeared D7-branes and the flavor symmetry group is thus a product of abelian factors.Comment: 27 pages; v2: 29 pages, 1 (new) figure, new section 4.4 on optical properties, references, comments added; v3: eq. (3.19), comments and a reference adde

    Three-dimensional coherent X-ray diffraction imaging of a ceramic nanofoam: determination of structural deformation mechanisms

    Full text link
    Ultra-low density polymers, metals, and ceramic nanofoams are valued for their high strength-to-weight ratio, high surface area and insulating properties ascribed to their structural geometry. We obtain the labrynthine internal structure of a tantalum oxide nanofoam by X-ray diffractive imaging. Finite element analysis from the structure reveals mechanical properties consistent with bulk samples and with a diffusion limited cluster aggregation model, while excess mass on the nodes discounts the dangling fragments hypothesis of percolation theory.Comment: 8 pages, 5 figures, 30 reference

    Formation of dense partonic matter in relativistic nucleus-nucleus collisions at RHIC: Experimental evaluation by the PHENIX collaboration

    Full text link
    Extensive experimental data from high-energy nucleus-nucleus collisions were recorded using the PHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The comprehensive set of measurements from the first three years of RHIC operation includes charged particle multiplicities, transverse energy, yield ratios and spectra of identified hadrons in a wide range of transverse momenta (p_T), elliptic flow, two-particle correlations, non-statistical fluctuations, and suppression of particle production at high p_T. The results are examined with an emphasis on implications for the formation of a new state of dense matter. We find that the state of matter created at RHIC cannot be described in terms of ordinary color neutral hadrons.Comment: 510 authors, 127 pages text, 56 figures, 1 tables, LaTeX. Submitted to Nuclear Physics A as a regular article; v3 has minor changes in response to referee comments. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (or will be) publicly available at http://www.phenix.bnl.gov/papers.htm

    The impact of hoist sling materials on interface pressure whilst sitting in healthy volunteers and wheelchair users : a comparative study

    Get PDF
    Aim of the study To evaluate the effect of three sling fabrics on gluteal interface pressure whilst sitting in a population of wheelchair users and to compare these to data previously collected in a pilot study with a healthy population. Materials and methods A repeated measures experimental design was used with 32 adult wheelchair users (15 women, 17 men). Healthy population pilot study consisted of 61 participants (51 women, 10 men) recruited from staff and students at The University of Salford. Methods Gluteal pressures at six pressure zones were recorded using the X-sensor PX100 pressure sensor at 30 second intervals for 10 minutes. Data were collected in 4 conditions with participants seated in a standardised chair, followed by the chair with slings made of three different fabrics. Results The spacer fabric reduced the mean gluteal pressure more effectively than slipfit and polyester (p=0.014 and p=0.01 respectively, 95%CI) and reduced peak pressure at the left ischial tuberosity and coccyx when compared to the slipfit (p=0.003 and p=0.005) with the wheelchair users. When comparing data with the pilot study, the mean gluteal pressure and peak pressures at the ischial tuberosities and coccyx were significantly higher in the wheelchair user group (p<0.005). Conclusion The fabric identified as the most effective in reducing mean and peak pressures in both groups was the spacer fabric, suggesting that a spacer fabric sling is more likely to reduce the risk of pressure ulcer development. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors

    What is case management in palliative care? An expert panel study

    Get PDF
    Contains fulltext : 110207.pdf (publisher's version ) (Open Access)ABSTRACT: BACKGROUND: Case management is a heterogeneous concept of care that consists of assessment, planning, implementing, coordinating, monitoring, and evaluating the options and services required to meet the client's health and service needs. This paper describes the result of an expert panel procedure to gain insight into the aims and characteristics of case management in palliative care in the Netherlands. METHODS: A modified version of the RAND(R)/University of California at Los Angeles (UCLA) appropriateness method was used to formulate and rate a list of aims and characteristics of case management in palliative care. A total of 76 health care professionals, researchers and policy makers were invited to join the expert panel, of which 61% participated in at least one round. RESULTS: Nine out of ten aims of case management were met with agreement. The most important areas of disagreement with regard to characteristics of case management were hands-on nursing care by the case manager, target group of case management, performance of other tasks besides case management and accessibility of the case manager. CONCLUSIONS: Although aims are agreed upon, case management in palliative care shows a high level of variability in implementation choices. Case management should aim at maintaining continuity of care to ensure that patients and those close to them experience care as personalised, coherent and consistent

    Results from the first use of low radioactivity argon in a dark matter search

    Get PDF
    Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).Comment: Accepted by Phys. Rev.

    Quantitative Constraints on the Transport Properties of Hot Partonic Matter from Semi-Inclusive Single High Transverse Momentum Pion Suppression in Au+Au collisions at sqrt(s_NN) = 200 GeV

    Full text link
    The PHENIX experiment has measured the suppression of semi-inclusive single high transverse momentum pi^0's in Au+Au collisions at sqrt(s_NN) = 200 GeV. The present understanding of this suppression is in terms of energy-loss of the parent (fragmenting) parton in a dense color-charge medium. We have performed a quantitative comparison between various parton energy-loss models and our experimental data. The statistical point-to-point uncorrelated as well as correlated systematic uncertainties are taken into account in the comparison. We detail this methodology and the resulting constraint on the model parameters, such as the initial color-charge density dN^g/dy, the medium transport coefficient , or the initial energy-loss parameter epsilon_0. We find that high transverse momentum pi^0 suppression in Au+Au collisions has sufficient precision to constrain these model dependent parameters at the +/1 20%-25% (one standard deviation) level. These constraints include only the experimental uncertainties, and further studies are needed to compute the corresponding theoretical uncertainties.Comment: 422 authors, 13 pages text, RevTeX-4, 9 figures, 2 tables. This version is updated with changes made during the review process and is now the same as what was published in Physical Review C. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are publicly available at http://www.phenix.bnl.gov/papers.htm

    A review of squeaking in ceramic total hip prostheses

    Get PDF
    The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Considering multifactor contributing to this phenomenon, many studies have been conducted over the last decade. Great efforts have been put on understanding the mechanics of the hip squeaking to gain a deep insight into factors resulting in sound emission from hip articulation. Disruption of fluid-film lubrication and friction were reported as main potential causes of hip squeaking, while patient and surgical factors as well as design and material of hip implants were identified as affecting factors. This review article therefore summarised the recent available literature on this subject to provide a platform for future developments. Moreover, high wear rates and ceramic liner fracture as viable consequences of hip squeaking were discussed.The first author gratefully acknowledges Macquarie University for International Macquarie University Research Excellence Scholarship (iMQRES)-No. 2010017. The second author would like to thank to the Portuguese Foundation for Science and Technology through the project UID/EEA/04436/2013
    corecore