5,578 research outputs found

    Sensitivity Analysis of Stress State and Bond Strength of Fiber-reinforced Polymer/Concrete Interface to Boundary Conditions in Single Shear Pull-out Test

    Get PDF
    The bond between fiber-reinforced polymer and concrete substrate plays a key role in the performance of concrete structures after strengthened by externally bonded fiber-reinforced polymer composite materials. The single shear pull-out test is generally used to determine the interface characteristics, and various bond–slip models have been proposed based on the results of this test. However, the sensitivity of the bond strength to the boundary conditions has not yet been considered in the available models in the literatures. This article presents an experimental and numerical study targeted at understanding the influence of the boundary conditions on the bond strength of the fiber-reinforced polymer/concrete interface in the single shear pull-out test. The validated finite element analysis by experimental results is used for the sensitivity study of the bond strength and stress state of the interface to the boundary conditions of the concrete block. It is found that the constraint height of the concrete block at the loaded side is an influential parameter on the stress state of the interface and the bond strength

    Finite Element Analysis of FRP Debonding Failure at the Tip of Flexural/Shear Crack in Concrete Beam

    Get PDF
    One of the most common failure modes of strengthened RC beams with externally bonded FRP is intermediate crack (IC) debonding of FRP initiated at the tip of flexural/shear cracks. This study presents a method, using extended finite element method (XFEM), to model IC debonding in an FRP-strengthened concrete beam. In XFEM, as soon as a damage initiation criterion is reached in an element, additional degrees of element freedom are added to model crack initiation. Crack propagation is then modeled using fracture energy criterion. This method can be used to simulate debonding failure along an arbitrary, solution-dependent path without the requirement of remeshing. The numerical results are validated against experimental data and good agreement is found. A sensitivity analysis is conducted to study the effects of damage band properties and geometry on FRP debonding failure. This verifies that shear strength and critical mode II fracture energy are the parameters most affecting the FRP debonding model when the crack tip is subjected to mode II loading

    An Improved Traffic Matrix Decomposition Method with Frequency-Domain Regularization

    Full text link
    We propose a novel network traffic matrix decomposition method named Stable Principal Component Pursuit with Frequency-Domain Regularization (SPCP-FDR), which improves the Stable Principal Component Pursuit (SPCP) method by using a frequency-domain noise regularization function. An experiment demonstrates the feasibility of this new decomposition method.Comment: Accepted to IEICE Transactions on Information and System

    Bond–slip Behavior of Fiber-reinforced Polymer/concrete Interface in Single Shear Pull-out and Beam Tests

    Get PDF
    It has been assumed that the fiber-reinforced polymer/concrete interface is subjected to in-plane shear condition when intermediate crack debonding failure occurs. Therefore, the single shear pull-out test results are often used to predict the intermediate crack debonding failure in beams. In this study, the behavior of fiber-reinforced polymer-strengthened concrete beams and single shear pull-out specimens were studied experimentally and numerically. The bond–slip behavior of the fiber-reinforced polymer/concrete interface was obtained by single shear pull-out and beam tests. In all beam specimens, a concrete wedge located at the edge of the notch detached with the fiber-reinforced polymer debonding failure. This phenomenon shows that the initiation of debonding is due to a diagonal crack formation close to the major flexural/shear crack inside the concrete. The diagonal crack formation is due to a local moment at the tip of the notch. This causes the different stress state and slip of the fiber-reinforced polymer/concrete interface of beam specimens from that of the pull-out specimens. It is found that the bond–slip relation obtained from the pull-out test does not represent the bond–slip relation of the fiber-reinforced polymer/concrete interface in the fiber-reinforced polymer-strengthened concrete beams, and it cannot be directly used for predicting the load capacity of the fiber-reinforced polymer-strengthened concrete beams
    corecore