2,381 research outputs found
The 1/5-th Rule with Rollbacks: On Self-Adjustment of the Population Size in the GA
Self-adjustment of parameters can significantly improve the performance of
evolutionary algorithms. A notable example is the
genetic algorithm, where the adaptation of the population size helps to achieve
the linear runtime on the OneMax problem. However, on problems which interfere
with the assumptions behind the self-adjustment procedure, its usage can lead
to performance degradation compared to static parameter choices. In particular,
the one fifth rule, which guides the adaptation in the example above, is able
to raise the population size too fast on problems which are too far away from
the perfect fitness-distance correlation.
We propose a modification of the one fifth rule in order to have less
negative impact on the performance in scenarios when the original rule reduces
the performance. Our modification, while still having a good performance on
OneMax, both theoretically and in practice, also shows better results on linear
functions with random weights and on random satisfiable MAX-SAT instances.Comment: 17 pages, 2 figures, 1 table. An extended two-page abstract of this
work will appear in proceedings of the Genetic and Evolutionary Computation
Conference, GECCO'1
Contribution de l'infirmière de pratique avancée en diabétologie: Le soin à la personne âgée diabétique
Automatic adjustment of noninvasive pressure support with abilevel home ventilator in patients with acute respiratory failure: afeasibility study
Objective: To test the feasibility of applying noninvasive ventilation (NIV) using aprototype algorithm implemented in abilevel ventilation device designed to adjust pressure support (PS) to maintain aclinician-set alveolar ventilation in patients with acute respiratory failure after initial stabilization. Design and setting: Prospective crossover interventional study in an intensive care unit, university hospital. Patients: 19 patients receiving NIV for acute hypercapnic respiratory failure (13 men, 6 women; mean age 70 ± 11 years). Methods: The same bilevel ventilator was used with manually adjusted PS and with the automated algorithm (autoPS), set to maintain the same alveolar ventilation as in PS. Sequence (measurements at end of each period): (a) prior to initiating NIV (baseline 1); (b) 45 min with manually set PS; (c) 60 min without NIV; (d) 45 min with autoPS; (e) 60 min without NIV; (f) 45 min with manually set PS. Results: The magnitude of decrease in PaCO2 and increase in pH with autoPS was comparable to that of conventional PS, with the same alveolar ventilation and level of PS. No technical problem occurred in autoPS mode, and no NIV trial had to be discontinued because of patient discomfort. Conclusions: These results suggest that the alveolar ventilation based automatic control of PS during NIV with abilevel device is feasible and leads to beneficial effects in patients with acute respiratory failure comparable to those of manually set PS. Further studies should now explore the potential of this system over longer periods in patients with acute and chronic respiratory failur
Ecological niche overlap in sister species: how do oil-collecting bees Macropis europaea and Macropis fulvipes (Hymenoptera: Melittidae) avoid hybridization and competition?
Oil-collecting bees are found worldwide and always in association with particular oil-producing flowers. In the Western Palearctic, three oil-collecting bee species within the genus Macropis (Hymenoptera, Melittidae) interact in a tight pollination mutualism with species of the only European oil-producing plant genus Lysimachia L. (Myrsinaceae). Two of these oil-collecting bees (Macropis europaea and Macropis fulvipes) show overlapping geographic distributions, comparable morphologies, and similar ecological characteristics (e.g., habitat type, floral preferences). In view of these similarities, we presume that hybridization should occur between the two species unless potential variation among the species' ecological niches prevents it, simultaneously decreasing competition for resources. Using modern genetic analyses and ecological niche modeling on a large bee sampling throughout Europe, we discuss new perspectives on the ecology and evolutionary history of this mutualis
Synthesis and Spectral Characterization of Benzo[6,7] [1,5]diazocino[2,1-a]isoindol-12-(14H)-one Derivatives
© 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).A simple synthetic route to benzo[6,7][1,5]diazocino[2,1-a]isoindol-12(14H)-one ring system is developed from readily available starting materials 3-(2-oxo-2-phenylethyl) isobenzofuran-1(3H)-ones and 2-(aminomethyl)aniline catalysed by para-toluenesulfonic acid in toluene in 27-85% yields. The 1H- and 13C-NMR spectra of the final products were assigned using a variety of one and two-dimensional NMR experiments. The distinction between the two potential isomers of the final products was made on the basis of heteronuclear multiple bond connectivity NMR spectra (HMBC).Peer reviewe
Bioimpedance spectroscopy for swelling evaluation following total knee arthroplasty: a validation study
BACKGROUND: The evaluation of swelling is important for the outcome of total knee arthroplasty (TKA) surgery. The circumference or volume measurements are applicable at the bedside of the patient but are altered by muscular atrophy and the post-surgical dressing. Bioimpedance spectroscopy might overcome these limitations; however, it should be validated. This study aimed to explore the validity, the reliability and the responsiveness of bioimpedance spectroscopy for measuring swelling after TKA.
METHODS: The degree of swelling in 25 patients undergoing TKA surgery was measured using bioimpedance spectroscopy (BIS R0), knee circumference and limb volume. The measurements were performed on D-1 (day before surgery), D + 2 (2 days after surgery) and D + 8 (8 days after surgery). The BIS R0 measurements were repeated twice, alternating between two evaluators. The percentage of the difference between the limbs was calculated for BIS R0, circumference and volume. The intra- and inter-observer intraclass correlation coefficients (ICCs), limits of agreement (LOA), effect size (Cohen's d), correlations between the methods and diagnostic sensitivity were calculated.
RESULTS: BIS R0, circumference and volume detected swelling < 3.5% at D-1. The swelling at D2 and D8 was greater with BIS R0 [mean (SD) 29.9% (±9.8) and 38.27 (±7.8)] than with volume [14.7 (±9.5) and 14.9 (±8.2)] and circumference [11.1 (±5.7) and 11.7 (±4.1)]. The BIS R0 intra- and inter-evaluator ICCs ranged from 0.89 to 0.99, whereas the LOA were < 5.2%. The BIS R0 correlation was 0.73 with volume and 0.75 with circumference. The BIS R0 Cohen's d was 3.32 for the D-1-D2 evolution. The diagnostic sensitivity was 83% D2 and 96% at D8.
CONCLUSION: Bioimpedance is a valid method for the evaluation of swelling following TKA. BIS R0 also demonstrated excellent intra- and inter-evaluator reliability. The diagnostic sensitivity and responsiveness is superior to that of concurrent methods. BIS R0 is an efficient method for post-surgical follow up at the bedside of the patient. The measurement of BIS R0 is a straightforward, valid, reliable and responsive method for lower limb swelling following TKA surgery that could be used in clinics and research.
TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00627770
Alteration and recovery of arm usage in daily activities after rotator cuff surgery.
BACKGROUND: The objective measurement of dominant/nondominant arm use proportion in daily life may provide relevant information on healthy and pathologic arm behavior. This prospective case-control study explored the potential of such measurements as indicators of upper limb functional recovery after rotator cuff surgery.
METHODS: Data on dominant/nondominant arm usage were acquired with body-worn sensors for 7 hours. The postsurgical arm usage of 21 patients was collected at 3, 6, and 12 months after rotator cuff surgery in the sitting, walking, and standing postures and compared with a reference established with 41 healthy subjects. The results were calculated for the dominant and nondominant surgical side subgroups at all stages. The correlations with clinical scores were calculated.
RESULTS: Healthy right-handed and left-handed dominant arm usage was 60.2% (±6.3%) and 53.4% (±6.6%), respectively. Differences in use of the dominant side were significant between the right- and left-handed subgroups for sitting (P = .014) and standing (P = .009) but not for walking (P = .328). The patient group showed a significant underuse of 10.7% (±8.9%) at 3 months after surgery (P < .001). The patients recovered normal arm usage within 12 months, regardless of surgical side. The arm underuse measurement was weakly related to function and pain scores.
CONCLUSION: This study provided new information on arm recovery after rotator cuff surgery using an innovative measurement method. It highlighted that objective arm underuse measurement is a valuable indicator of upper limb postsurgical outcome that captures a complementary feature to clinical scores
- …
