1,741 research outputs found
Mediators of leukocyte yctivation play a role in disseminated intravascular coagulation during orthotopic liver transplantation
Leukocytes play an important role in the development of disseminated intravascular coagulation (DIC). In the reperfusion phase of OLT a DIC-like situation has been described and has been held responsible for the high blood loss during this phase.
We investigated the role of leukocytes in the pathogenesis of DIC in OLT by measuring the leukocytic mediators released upon activation (cathepsin B, elastase, TNF, neopterin) and the levels of thrombin-antithrombin III (TAT) complexes, seen as markers of prothrombin activation. Arterial blood samples were taken at 10 different time points during and after OLT. Samples were also taken of the perfusate released from the liver graft vein during the flushing procedure before the reperfusion phase. Aprotinin was given as a continuous infusion (0.2-0.4 Mill. KlU/hr) and its plasma levels were determined.
Significantly elevated levels of neopterin (15-fold; P<0.01), cathepsin B (440-fold; P<0.01) in the perfusate, as compared with the systemic circulation, as well as their significant increases in the early reperfusion phase suggested that they were released by the graft liver. This was paralleled by elevated levels of elastase (1.3-fold, P<0.05), TNF (1.5-fold, P=NS), and TAT complexes (1.4-fold; P<0.1) in the perfusate. Significant correlations could be identified between the parameters of leukocyte activation and TAT complexes, whereas no correlation was observed between any of the parameters investigated and the aprotinin levels.
Our results strongly indicate a release of leukocytic mediators from the graft liver during its reperfusion which seems to be related to the parallely increased prothrombin activation. No correlation could be seen between levels of aprotinin and levels of leukocytic mediators
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
In this paper, we report high-precision absolute distance and vibration
measurements performed with frequency scanned interferometry using a pair of
single-mode optical fibers. Absolute distance was determined by counting the
interference fringes produced while scanning the laser frequency. A
high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency
changes during scanning. Two multiple-distance-measurement analysis techniques
were developed to improve distance precision and to extract the amplitude and
frequency of vibrations. Under laboratory conditions, measurement precision of
50 nm was achieved for absolute distances ranging from 0.1 meters to 0.7
meters by using the first multiple-distance-measurement technique. The second
analysis technique has the capability to measure vibration frequencies ranging
from 0.1 Hz to 100 Hz with amplitude as small as a few nanometers, without a
priori knowledge.Comment: 16 pages, 7 figures, 1 table, accepted for publication in Applied
Optic
High-precision Absolute Distance Measurement using Dual-Laser Frequency Scanned Interferometry Under Realistic Conditions
In this paper, we report on new high-precision absolute distance measurements
performed with frequency scanned interferometry using a pair of single-mode
optical fibers. Absolute distances were determined by counting the interference
fringes produced while scanning the frequencies of the two chopped lasers.
High-finesse Fabry-Perot interferometers were used to determine frequency
changes during scanning. Dual lasers with oppositely scanning directions,
combined with a multi-distance-measurement technique previously reported, were
used to cancel drift errors and to suppress vibration effects and interference
fringe uncertainties. Under realistic conditions, a precision about 0.2 microns
was achieved for a distance of 0.41 meters.Comment: 14 pages, 5 figures, submitted to Applied Optic
SEMS vs cSEMS in duodenal and small bowel obstruction : high risk of migration in the covered stent group
Aim: To compare clinical success and complications of uncovered self-expanding metal stents (SEMS) vs covered SEMS (cSEMS) in obstruction of the small bowel.
Methods: Technical success, complications and outcome of endoscopic SEMS or cSEMS placement in tumor related obstruction of the duodenum or jejunum were retrospectively assessed. The primary end points were rates of stent migration and overgrowth. Secondary end points were the effect of concomitant biliary drainage on migration rate and overall survival. The data was analyzed according to the Strengthening the Reporting of Observational Studies in Epidemiology guidelines.
Results: Thirty-two SEMS were implanted in 20 patients. In all patients, endoscopic stent implantation was successful. Stent migration was observed in 9 of 16 cSEMS (56%) in comparison to 0/16 SEMS (0%) implantations (P = 0.002). Stent overgrowth did not significantly differ between the two stent types (SEMS: 3/16, 19%; cSEMS: 2/16, 13%). One cSEMS dislodged and had to be recovered from the jejunum by way of laparotomy. Time until migration between SEMS and cSEMS in patients with and without concomitant biliary stents did not significantly differ (HR = 1.530, 95%CI 0.731-6.306; P = 0.556). The mean follow-up was 57 ± 71 d (range: 1-275 d).
Conclusion: SEMS and cSEMS placement is safe in small bowel tumor obstruction. However, cSEMS is accompanied with a high rate of migration in comparison to uncovered SEMS
Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling.
Giant magnetoresistive (GMR) sensors have been shown to be among the most sensitive biosensors reported. While high-density and scalable sensor arrays are desirable for achieving multiplex detection, scalability remains challenging because of long data acquisition time using conventional readout methods. In this paper, we present a scalable magnetoresistive biosensor array with an on-chip magnetic field generator and a high-speed data acquisition method. The on-chip field generators enable magnetic correlated double sampling (MCDS) and global chopper stabilization to suppress 1/f noise and offset. A measurement with the proposed system takes only 20 ms, approximately 50× faster than conventional frequency domain analysis. A corresponding time domain temperature correction technique is also presented and shown to be able to remove temperature dependence from the measured signal without extra measurements or reference sensors. Measurements demonstrate detection of magnetic nanoparticles (MNPs) at a signal level as low as 6.92 ppm. The small form factor enables the proposed platform to be portable as well as having high sensitivity and rapid readout, desirable features for next generation diagnostic systems, especially in point-of-care (POC) settings
Comparison of the collagen haemostat Sangustop(R) versus a carrier-bound fibrin sealant during liver resection; ESSCALIVER-study
Background: Haemostasis in liver surgery remains a challenge despite improved resection techniques. Oozing from blood vessels too small to be ligated necessitate a treatment with haemostats in order to prevent complications attributed to bleeding. There is good evidence from randomised trials for the efficacy of fibrin sealants, on their own or in combination with a carrier material. A new haemostatic device is Sangustop(R). It is a collagen based material without any coagulation factors. Pre-clinical data for Sangustop(R) showed superior haemostatic effect. This present study aims to show that in the clinical situation Sangustop(R) is not inferior to a carrier-bound fibrin sealant (Tachosil(R)) as a haemostatic treatment in hepatic resection. Methods: This is a multi-centre, patient-blinded, intra-operatively randomised controlled trial. A total of 126 patients planned for an elective liver resection will be enrolled in eight surgical centres. The primary objective of this study is to show the non-inferiority of Sangustop(R) versus a carrier-bound fibrin sealant (Tachosil(R)) in achieving haemostasis after hepatic resection. The surgical intervention is standardised with regard to devices and techniques used for resection and primary haemostasis. Patients will be followed-up for three months for complications and adverse events. Discussion: This randomised controlled trial (ESSCALIVER) aims to compare the new collagen haemostat Sangustop(R) with a carrier-bound fibrin sealant which can be seen as a "gold standard" in hepatic and other visceral organ surgery. If non-inferiority is shown other criteria than the haemostatic efficacy (e.g. costs, adverse events rate) may be considered for the choice of the most appropriate treatment. Trial Registration: NCT0091861
Different aprotinin applications influencing hemostatic chances in orthotopic liver transplantation
The effect of different aprotinin applications on hemmtatic changes and blood product requirements in orthotopic liver transplantation was investigated in a prospective, open, and randomized study.
From November 1989 to June 1990, 13 patients received aprotinin as a bolus of 0.5 Mill, kallikrein inac-tivator units (KIU) on three occasions in the course of an OLT, whereas 10 other patients were treated with continuous aprotinin infusion of 0.1-0.4 Mill. KIU/hr. Before and after reperfusion of the graft liver, signs of hyperfibrinolysis, measured by thrombelastography, were significantly lower in the infusion group. Tissue-type plasminogen activator (t-PA) activity increased during the anhepatic phase but to a significantly lesser extent in the infusion group. Blood product requirements during OLT were tendentiously higher in the bolus group but not significantly so. However, the use of packed red blood cells was significantly lower in the postoperative period, whereas there was no significant difference in fresh frozen plasma requirements between the two groups.
All 23 patients have survived, and only one woman of each group required retransplantation due to severe host-versus-graft reactions.
Furthermore, we investigated the perfusate of the graft liver in both groups and detected signs of a decreased t-PA release in the infusion group.
Our results demonstrate an advantage of aprotinin given as continuous infusion over bolus application in OLT
Prognostische Bedeutung der R1 Resektion : verbessertes Überleben in der Ära elektiver Chemotherapie
Einleitung: Die Resektion kolorektaler Lebermetastasen ist der alleinigen Chemotherapie überlegen und erfolgt unter kurativer Zielsetzung. Multimodale Therapiekonzepte erlauben zunehmend primär irresektable Metastasen sekundär zu resezieren. Bei einem Teil der Patienten wird das Ziel der Tumorfreiheit nicht erreicht. Anhand einer retrospektiven Analyse wurde der Anteil der nicht kurativ resezierten Patienten nach primärer und sekundärer Resektion und ihr Überleben bestimmt. Material und Methoden: Bei 152 Patienten wurden zwischen 1/02 – 7/07 insgesamt 174 Leberresektionen aufgrund kolorektaler Metastasen durchgeführt. Dieses Kollektiv wurde anhand des R-Status der Leberresektion in eine kurativ- (Gruppe I) und in eine nicht kurativ resezierte Gruppe (Gruppe II) unterteilt. Die Auswertung erfolgte retrospektiv nach Überleben, Metastasenausdehnung, neoadjuvanter Chemotherapie und primärem Tumorstadium. Ergebnisse: 174 Leberresektionen schlossen 44 Re-Resektion und 6 zweizeitige Resektionen ein. Bei 61 Patienten erfolgte eine neoadjuvante Chemotherapie vor der Leberresektion. Die demographischen Daten beider Gruppen zeigten keinen signifikanten Unterschied (Gr. I: Männer: 60%, Alter: 63+/-1; Gr. II: Männer: 65%, Alter: 57+/-2,4). Die Anzahl der resezierten Metastasen war in Gruppe II signifikant höher (Gr. I: 1,5+/-0,1; Gr. II: 3,5+/-0,7, p<0,01), während die lokale Primärtumor-Ausdehnung gemessen am T-Stadium (Gr. I: 2,8 +/- 0,1, Gr. II: 2,8 +/- 0,13, n.s.) keinen Unterschied zeigte. Der Anteil der nicht kurativ resezierten Patienten war nach primärer und sekundärer Resektion gleich (17% vs. 21%, n.s.). Das Gesamtüberleben (4-Jahre, Kaplan-Meier) (Gr. I: 61%, Gr. II: 29%, p<0,05) und das mediane Überleben (Gr. I: 4,4, Gr. II: 2,4 [Jahre], p<0,05) wiesen einen signifikanten Unterschied auf. Schlussfolgerung: Der R-Status nach Resektion kolorektaler Lebermetastasen ist weiterhin ein entscheidender prognostischer Faktor. R-1 resezierte Patienten erreichen jedoch mit 2,4 Jahren ein besseres medianes Überleben als vergleichbare historische Kollektive. Sekundäre Resektionen nach neoadjuvanter Therapie weisen eine vergleichbar hohe Rate an R1 Resektionen auf wie bei primären Resektionen
Anastomoseninsuffizienz nach kolorektalen Resektionen : welche Aussagekraft hat der Verlauf des C-reaktiven Proteins (CRP)?
Einleitung: Anastomoseninsuffizienzen sind schwerwiegende Komplikationen nach Kolonresektionen. Nur selten sind klinische oder laborchemische Zeichen Vorboten einer Insuffizienz. Material und Methoden: Wir haben unser Patientenkollektiv nach kolorektalen Resektionen retrospektiv untersucht in Hinblick auf einen Anstieg des C-rektiven Proteins (CRP) postoperativ als Zeichen einer Insuffizienz. Hierzu wurde der Unterschied vom präoperativen Messwert zum Messwert am 1. bis 7. postoperativen Tag berechnet. Bei Patienten mit Anastomoseninsuffizienz wurden die Werte nur bis zum Tag der Insuffizienz einbezogen, um einen Anstieg durch eine eventuelle Revision auszuklammern. Ergebnisse: Im Zeitraum von 8/2002 bis 8/2005 wurden bei 342 Patienten eine Kolonresektion durchgeführt. Im einzelnen waren dies 101 (29,5%) Sigmaresektionen, 89 (26,0%) Hemikolektomien rechts, 56 (16,4%) Rektumresektionen, 38 (11,1%) Ileocoecalresektionen, 24 (7,0%) Hemikolektomien links, 22 (6,4%) Segmentresektionen, 12 (3,5%) Kolektomien. Das Alter der Patienten lag bei 61,6 +/- 15,0 Jahren. Es wurden 142 (41,5%) Frauen und 200 (58,5%) Männer operiert, 301 (88%) Patienten elektiv und 41 (12%) als Notfall. Die Inzidenz von symptomatischen und asymptomatischen Anastomosen-insuffizienzen lag im Gesamtkollektiv bei 26/342 (7,6%), sie traten durchschnittlich 8,7 +/- 7,1 (1-27) Tage nach der Operation auf. Eine Analyse der CRP-Werte ergab bei den Patienten die im Verlauf eine Anastomoseninsuffizienz entwickelten signifikant höhere Anstiege von präoperativ bis zum 3. (+10,9 mg/dl versus +16,5 mg/dl, p=0,018), 5. (+4,2 mg/dl versus +13,1 mg/dl, p=0,002), 6. (+3,8 mg/dl versus +14,6 mg/dl, p=0,002), und 7. (+2,8 mg/dl versus +18,3 mg/dl, p<0,001) postoperativen Tag. Die Differenz zum 4. postoperativen Tag zeigte keinen signifikanten Unterschied (+6,5 mg/dl versus +11,2 mg/dl, p=0,3). Die absoluten Messwerte waren nicht signifikant unterschiedlich. Andere Laborparameter wie Leukozyten, Kreatinin, Albumin ergaben keinen Unterschied im Vergleich der beiden Gruppen.Die Untersuchung von Risikofaktoren für eine Anastomoseninsuffizienz konnte keinen signifikanten Unterschied zeigen für: Alter, Geschlecht, ASA, OP-Dauer, Zugang (offen oder laparoskopisch), benigne oder maligne Erkrankung, Kolon- oder Rektumresektion, elektive oder Notfalloperation. Schlussfolgerung: Der Verlauf des CRP ist ein signifikanter Marker für das Auftreten von Anastomoseninsuffizienzen nach kolorektalen Resektionen
- …
