5,282 research outputs found
Redox Switchable Thianthrene Cavitands
A redox activated vase-to-kite conformational change is reported for a new resorcinarene-based cavitand appended with four quinoxaline-fused thianthrene units. In its neutral state, the thianthrene-containing cavitand was shown by 1H NMR to adopt a closed vase conformation. Upon oxidation the electrostatic repulsion among the thianthrene radical cations promotes a kite conformation in the thianthrene-containing cavitand. The addition of acid produced a shoulder feature below 300 nm in the cavitand’s UV-Vis spectrum that we have assigned to the vase-to-kite conformation change. UV-Vis spectroelectrochemical studies of the cavitand revealed a development of a similar shoulder peak consistent with the oxidation-induced vase-to-kite conformation change. To support that the shoulder peak is diagnostic for a vase-to-kite conformation change, a model molecule constituting a single quinoxaline wall of the cavitand was synthesized and studied. As expected UV-Vis spectroelectrochemical studies of the cavitand arm did not display a shoulder peak below 300 nm. The oxidation-induced vase-to-kite conformation is further confirmed by the distinctive upfield shift in 1H chemical shift of the methine signal. Key words: redox active, thianthrene, resorcinarene cavitands, electrochemical switching, conformation changeNational Science Foundation (U.S.). Center for Energy Efficient Electronics Science (Award ECCS0939514)Singapore. Agency for Science, Technology and Research (Graduate Scholarship
High-resolution tracking in a GEM-Emulsion detector
SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the
CERN SPS aiming at the observation of long lived particles very weakly coupled
with ordinary matter mostly produced in the decay of charmed hadrons. The beam
dump facility of SHiP is also a copious factory of neutrinos of all three kinds
and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus.
The neutrino detector exploits the Emulsion Cloud Chamber technique with a
modular structure, alternating walls of target units and planes of electronic
detectors providing the time stamp to the event. GEM detectors are one of the
possible choices for this task. This paper reports the results of the first
exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a
GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the
emulsion detector, the position resolution of the GEM chamber as a function of
the particle inclination was evaluated in two configurations, with and without
the magnetic fiel
Aplicação do método AID estendido na identificação de linhagens de frangos resistentes a coccidiosis (Eimeria tenella).
O objetivo foi analisar dados de pesagens (y) de bovinos. De cada animal foram feitas nove pesagens do nascimento aos dois anos de idade. A variável y foi transformada por yl = (yl-1)/l (l 1 0), a qual foi eficiente na redução dos coeficientes de assimetria e da heterogeneidade de variância dos dados
A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector
that collects data provided by the collision in the Beijing Electron Positron
Collider II (BEPCII), hosted at the Institute of High Energy Physics of
Beijing. Since the beginning of its operation, BESIII has collected the world
largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the
luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC
decreases its efficiency in the first layers up to 35% with respect to the
value in 2014. Since BESIII has to take data up to 2022 with the chance to
continue up to 2027, the Italian collaboration proposed to replace the inner
part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM).
The CGEM-IT project will deploy several new features and innovation with
respect the other current GEM based detector: the {\mu}TPC and analog readout,
with time and charge measurements will allow to reach the 130 {\mu}m spatial
resolution in 1 T magnetic field requested by the BESIII collaboration. In this
proceeding, an update of the status of the project will be presented, with a
particular focus on the results with planar and cylindrical prototypes with
test beams data. These results are beyond the state of the art for GEM
technology in magnetic field
Quantum dynamics under coherent and incoherent effects of a spin bath in the Keldysh formalism: application to a spin swapping operation
We develop the Keldysh formalism for the polarization dynamics of an open
spin system. We apply it to the swapping between two qubit states in a model
describing an NMR cross-polarization experiment. The environment is a set of
interacting spins. For fast fluctuations in the environment, the analytical
solution shows effects missed by the secular approximation of the Quantum
Master Equation for the density matrix: a frequency decrease depending on the
system-environment escape rate and the quantum quadratic short time behavior.
Considering full memory of the bath correlations yields a progressive change of
the swapping frequency.Comment: 16 pages, 3 figures, final for
emission rates in absorptions at rest on Li, Li, Be, C and O
An experimental study of the reaction
on Li, Li, Be, C and O -shell nuclei is
presented. The data were collected by the FINUDA spectrometer operating at the
DANE -factory (LNF-INFN, Italy). Emission rates for the reaction in
the mentioned nuclei are measured and compared with the few existing data. The
spectra of several observables are discussed; indications of Quasi-Free
absorptions by a pair embedded in the nucleus can be obtained from
the study of the missing mass distributions.Comment: Version accepted by PR
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC
proton collider (CERN, Switzerland) will employ an online gas analysis and
monitoring system of the freon-based gas mixture used. We give an overview of
the CMS RPC gas system, describe the project parameters and first results on
gas-chromatograph analysis. Finally, we report on preliminary results for a set
of monitor RPC.Comment: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali
di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 200
- …