5,282 research outputs found

    Redox Switchable Thianthrene Cavitands

    Get PDF
    A redox activated vase-to-kite conformational change is reported for a new resorcinarene-based cavitand appended with four quinoxaline-fused thianthrene units. In its neutral state, the thianthrene-containing cavitand was shown by 1H NMR to adopt a closed vase conformation. Upon oxidation the electrostatic repulsion among the thianthrene radical cations promotes a kite conformation in the thianthrene-containing cavitand. The addition of acid produced a shoulder feature below 300 nm in the cavitand’s UV-Vis spectrum that we have assigned to the vase-to-kite conformation change. UV-Vis spectroelectrochemical studies of the cavitand revealed a development of a similar shoulder peak consistent with the oxidation-induced vase-to-kite conformation change. To support that the shoulder peak is diagnostic for a vase-to-kite conformation change, a model molecule constituting a single quinoxaline wall of the cavitand was synthesized and studied. As expected UV-Vis spectroelectrochemical studies of the cavitand arm did not display a shoulder peak below 300 nm. The oxidation-induced vase-to-kite conformation is further confirmed by the distinctive upfield shift in 1H chemical shift of the methine signal. Key words: redox active, thianthrene, resorcinarene cavitands, electrochemical switching, conformation changeNational Science Foundation (U.S.). Center for Energy Efficient Electronics Science (Award ECCS0939514)Singapore. Agency for Science, Technology and Research (Graduate Scholarship

    High-resolution tracking in a GEM-Emulsion detector

    Full text link
    SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic fiel

    Aplicação do método AID estendido na identificação de linhagens de frangos resistentes a coccidiosis (Eimeria tenella).

    Get PDF
    O objetivo foi analisar dados de pesagens (y) de bovinos. De cada animal foram feitas nove pesagens do nascimento aos dois anos de idade. A variável y foi transformada por yl = (yl-1)/l (l 1 0), a qual foi eficiente na redução dos coeficientes de assimetria e da heterogeneidade de variância dos dados

    A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP

    Full text link
    The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/{\psi} and {\psi}(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the {\mu}TPC and analog readout, with time and charge measurements will allow to reach the 130 {\mu}m spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field

    Quantum dynamics under coherent and incoherent effects of a spin bath in the Keldysh formalism: application to a spin swapping operation

    Get PDF
    We develop the Keldysh formalism for the polarization dynamics of an open spin system. We apply it to the swapping between two qubit states in a model describing an NMR cross-polarization experiment. The environment is a set of interacting spins. For fast fluctuations in the environment, the analytical solution shows effects missed by the secular approximation of the Quantum Master Equation for the density matrix: a frequency decrease depending on the system-environment escape rate and the quantum quadratic short time behavior. Considering full memory of the bath correlations yields a progressive change of the swapping frequency.Comment: 16 pages, 3 figures, final for

    Σp\Sigma^- p emission rates in KK^- absorptions at rest on 6^6Li, 7^7Li, 9^{9}Be, 13^{13}C and 16^{16}O

    Full text link
    An experimental study of the KstopAΣpAK^-_{stop}A\rightarrow \Sigma^- p A' reaction on A=6A=^6Li, 7^7Li, 9^9Be, 13^{13}C and 16^{16}O pp-shell nuclei is presented. The data were collected by the FINUDA spectrometer operating at the DAΦ\PhiNE ϕ\phi-factory (LNF-INFN, Italy). Emission rates for the reaction in the mentioned nuclei are measured and compared with the few existing data. The spectra of several observables are discussed; indications of Quasi-Free absorptions by a (np)(np) pair embedded in the AA nucleus can be obtained from the study of the missing mass distributions.Comment: Version accepted by PR

    Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    Get PDF
    The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.Comment: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 200
    corecore