542 research outputs found

    Drug Hypersensitivity Syndrome toCarbamazepine and Human Herpes Virus 6 Infection: Case Reportand Literature Review

    Get PDF
    Abstract.: We describe a patient with a drug-induced hypersensitivity syndrome to carbamazepine and a concomitant active infection with human herpes virus 6 (HHV-6). The potential role of HHV-6 regarding the drug-induced hypersensitivity syndrome is discussed and the main clinical features of this potentially fatal adverse drug reaction are highlighte

    Crater formation by fast ions: comparison of experiment with Molecular Dynamics simulations

    Full text link
    An incident fast ion in the electronic stopping regime produces a track of excitations which can lead to particle ejection and cratering. Molecular Dynamics simulations of the evolution of the deposited energy were used to study the resulting crater morphology as a function of the excitation density in a cylindrical track for large angle of incidence with respect to the surface normal. Surprisingly, the overall behavior is shown to be similar to that seen in the experimental data for crater formation in polymers. However, the simulations give greater insight into the cratering process. The threshold for crater formation occurs when the excitation density approaches the cohesive energy density, and a crater rim is formed at about six times that energy density. The crater length scales roughly as the square root of the electronic stopping power, and the crater width and depth seem to saturate for the largest energy densities considered here. The number of ejected particles, the sputtering yield, is shown to be much smaller than simple estimates based on crater size unless the full crater morphology is considered. Therefore, crater size can not easily be used to estimate the sputtering yield.Comment: LaTeX, 7 pages, 5 EPS figures. For related figures/movies, see: http://dirac.ms.virginia.edu/~emb3t/craters/craters.html New version uploaded 5/16/01, with minor text changes + new figure

    SMOS calibration and validation activities with airborne interferometric radiometer HUT-2D during spring 2010

    Get PDF
    In this paper we present calibration and validation activities of European Space Agency’s SMOS mission, which utilize airborne interferomentric L-band radiometer system HUT-2D of the Aalto University. During spring 2010 the instrument was used to measure three SMOS validation target areas, one in Denmark and two in Germany. We present these areas shortly, and describe the airborne activities. We show some exemplary measurements of the radiometer system and demonstrate the studies using the data

    Skin testing in patients with hypersensitivity reactions to iodinated contrast media - a European multicenter study

    Get PDF
    BACKGROUND: Iodinated contrast media cause both immediate and nonimmediate hypersensitivity reactions. The aim of this prospective study was to determine the specificity and sensitivity of skin tests in patients who have experienced such reactions. METHODS: Skin prick, intradermal and patch tests with a series of contrast media were conducted in 220 patients with either immediate or nonimmediate reaction. Positive skin tests were defined according to internationally accepted guidelines. Seventy-one never-exposed subjects and 11 subjects who had tolerated contrast medium exposure, served as negative controls. RESULTS: Skin test specificity was 96-100%. For tests conducted within the time period from 2 to 6 months after the reaction, up to 50% of immediate reactors and up to 47% of nonimmediate reactors were skin test positive. For immediate reactors, the intradermal tests were the most sensitive, whereas delayed intradermal tests in combination with patch tests were needed for optimal sensitivity in nonimmediate reactors. Contrast medium cross-reactivity was more common in the nonimmediate than in the immediate group. Interestingly, 49% of immediate and 52% of nonimmediate symptoms occurred in previously unexposed patients. Many of these patients were skin test positive, indicating that they were already sensitized at the time of first contrast medium exposure. CONCLUSIONS: These data suggest that at least 50% of hypersensitivity reactions to contrast media are caused by an immunological mechanism. Skin testing appears to be a useful tool for diagnosis of contrast medium allergy and may play an important role in selection of a safe product in previous reactors

    Comparison of SMOS and SMAP Soil Moisture Retrieval Approaches Using Tower-based Radiometer Data over a Vineyard Field

    Get PDF
    The objective of this study was to compare several approaches to soil moisture (SM) retrieval using L-band microwave radiometry. The comparison was based on a brightness temperature (TB) data set acquired since 2010 by the L-band radiometer ELBARA-II over a vineyard field at the Valencia Anchor Station (VAS) site. ELBARA-II, provided by the European Space Agency (ESA) within the scientific program of the SMOS (Soil Moisture and Ocean Salinity) mission, measures multiangular TB data at horizontal and vertical polarization for a range of incidence angles (30-60). Based on a three year data set (2010-2012), several SM retrieval approaches developed for spaceborne missions including AMSR-E (Advanced Microwave Scanning Radiometer for EOS), SMAP (Soil Moisture Active Passive) and SMOS were compared. The approaches include: the Single Channel Algorithm (SCA) for horizontal (SCA-H) and vertical (SCA-V) polarizations, the Dual Channel Algorithm (DCA), the Land Parameter Retrieval Model (LPRM) and two simplified approaches based on statistical regressions (referred to as 'Mattar' and 'Saleh'). Time series of vegetation indices required for three of the algorithms (SCA-H, SCA-V and Mattar) were obtained from MODIS observations. The SM retrievals were evaluated against reference SM values estimated from a multiangular 2-Parameter inversion approach. The results obtained with the current base line algorithms developed for SMAP (SCA-H and -V) are in very good agreement with the reference SM data set derived from the multi-angular observations (R2 around 0.90, RMSE varying between 0.035 and 0.056 m3m3 for several retrieval configurations). This result showed that, provided the relationship between vegetation optical depth and a remotely-sensed vegetation index can be calibrated, the SCA algorithms can provide results very close to those obtained from multi-angular observations in this study area. The approaches based on statistical regressions provided similar results and the best accuracy was obtained with the Saleh methods based on either bi-angular or bipolarization observations (R2 around 0.93, RMSE around 0.035 m3m3). The LPRM and DCA algorithms were found to be slightly less successful in retrieving the 'reference' SM time series (R2 around 0.75, RMSE around 0.055 m3m3). However, the two above approaches have the great advantage of not requiring any model calibrations previous to the SM retrievals

    Skin testing in patients with hypersensitivity reactions to iodinated contrast media - a European multicenter study

    Get PDF
    BACKGROUND: Iodinated contrast media cause both immediate and nonimmediate hypersensitivity reactions. The aim of this prospective study was to determine the specificity and sensitivity of skin tests in patients who have experienced such reactions. METHODS: Skin prick, intradermal and patch tests with a series of contrast media were conducted in 220 patients with either immediate or nonimmediate reaction. Positive skin tests were defined according to internationally accepted guidelines. Seventy-one never-exposed subjects and 11 subjects who had tolerated contrast medium exposure, served as negative controls. RESULTS: Skin test specificity was 96-100%. For tests conducted within the time period from 2 to 6 months after the reaction, up to 50% of immediate reactors and up to 47% of nonimmediate reactors were skin test positive. For immediate reactors, the intradermal tests were the most sensitive, whereas delayed intradermal tests in combination with patch tests were needed for optimal sensitivity in nonimmediate reactors. Contrast medium cross-reactivity was more common in the nonimmediate than in the immediate group. Interestingly, 49% of immediate and 52% of nonimmediate symptoms occurred in previously unexposed patients. Many of these patients were skin test positive, indicating that they were already sensitized at the time of first contrast medium exposure. CONCLUSIONS: These data suggest that at least 50% of hypersensitivity reactions to contrast media are caused by an immunological mechanism. Skin testing appears to be a useful tool for diagnosis of contrast medium allergy and may play an important role in selection of a safe product in previous reactors

    Effect of thoracic venting on arterial pressure, and flow during external cardiopulmonary resuscitation in animals

    Get PDF
    To test the hypothesis that fluctuations in global intrathoracic pressure are the dominant cause of blood flow during external cardiopulmonary resuscitation (CPR) the authors studied the effects of open pneumothorax on experimental CPR in 7 domestic pigs and 12 mongrel dogs. Similar studies were conducted independently at three laboratories and are reported jointly. All studies were conducted during electrically induced ventricular fibrillation and with standard CPR technique, including ventral-dorsal chest compression at 60/min, 0.5 sec compression duration, 1:5ventilation:compression ratio. During alternate periods of CPR, intrathoracic pressure was vented through bilateral chest tubes, placed to create open pneumothorax and partial collapse of the lungs. During this maneuver, global intrathoracic pressure fluctuations were greatly attenuated, but direct but direct cardiac compression and adequate ventilation continued. In the three laboratories, systolic/diastolic arterial pressures during CPR with thoracic venting (± SE) averaged 68 ± 4.2/28 ± 3.3, 60 ± 10/18 ± 4.5, and 66 ± 6.3/23 ± 1.5 mm Hg. These values are compared to 68 ± 4.4/27 ± 3.0, 67 ± 12/17 ± 6.1, and 56± 6.2/22 ± 1.9 mm Hg with the thorax intact. Carotid artery mean flow, measured with an in-line flowmeter, was 13.0 ± 2.2 ml/min vented vs. 13.4 ± 2.6 intact in 7 pigs; 11.4 ± 3.8 ml/min vented vs. 11.2 ± 3.7 intact in 5 dogs. Cardiac output, determined by indicator dilution, was 25 ± 4.3 ml/min/kg vented vs. 20 ± 4.3 intact in 7 dogs. Thoracic venting did not decrease blood pressures and flows during CPR, as would be predicted from the hypothesis that generalized intrathoracic pressure fluctuations are the dominant hemodynamic mechanism. The results are consistent with the classical notion that CPR works by compression of the heart between the sternum and the spine. This mechanism should not be discounted in future attempts to improve CPR

    Methodology of calculation of construction and hydrodynamic parameters of a foam layer apparatus for mass-transfer processes

    Get PDF
    Промислова реалізація методу стабілізації газорідинного шару дозволяє значно розширити галузь застосування пінних апаратів і відкриває нові можливості інтенсифікації технологічних процесів з одночасним створенням маловідходних технологій. У статті встановлені основні параметри, що впливають на гідродинаміку пінних апаратів, розглянуті основні конструкції та режими роботи пінних апаратів. Виявлено зв'язок гідродинамічних параметрів. Розглянуто гідродинамічні закономірності пінного шару. Вказані фактори, що впливають на процес масообміну, як в газовій, так і в рідкій фазах. Проведений аналіз ряду досліджень показав, що перспективним напрямком інтенсифікації процесу масообміну є розробка апаратів з трифазним псевдозрідженим шаром зрошуваної насадки складних форм із сітчастих матеріалів. Отже, необхідне проведення спеціальних досліджень гідродинамічних режимів роботи апарату з сітчастою насадкою і визначенням параметрів, що впливають на швидкість переходу насадки з одного режиму в інший.Industrial implementation of the stabilization method of the gas-liquid layer can significantly expand the field of use of foaming apparatus and opens up new opportunities for intensifying technological processes with the simultaneous creation of low-waste technologies. The article establishes the basic parameters influencing the hydrodynamics of foam apparatus, considers the basic constructions and operating modes of foam apparatus. The connection of hydrodynamic parameters is revealed. The hydrodynamic laws of the foam layer are considered. The indicated factors affecting the process of mass transfer, both in the gas and in the liquid phases. The conducted analysis of a number of studies showed that the perspective direction of intensification of the mass transfer process is the development of apparatuses with a three-phase fluidized bed of an irrigated nozzle of complex forms with mesh materials
    corecore