13 research outputs found
Analysis of neuroretinal rim distribution and vascular pattern in eyes with presumed large physiological cupping: a comparative study
Background: To investigate possible differences in neuroretinal rim distribution, vascular pattern, and peripapillary region appearance between eyes with presumed large physiological optic disc cupping (pLPC) and eyes with minimal optic disc excavation.Methods: We prospectively enrolled consecutive subjects with pLPC and individuals with minimal excavation (optic disc excavation within normal limits; control group). All eyes had normal visual fields and untreated intraocular pressure (IOP) = 0.6 and >= 30 months of follow-up with no evidence of glaucomatous neuropathy. for controls, VCDR was limited to <= 0.5. We compared ocular signs and characteristics related to the neuroretinal rim distribution, vascular pattern, peripapillary region appearance and disc size between groups. Whenever both eyes were eligible, one was randomly selected for analysis.Results: A total of 74 patients (mean age, 45.6 +/- 14.9 years) with pLPC and 45 controls (mean age, 44.8 +/- 11.6 years) were enrolled (p = 0.76). Median disc size and VCDR was significantly larger in eyes with pLPC compared to controls (p < 0.01). the proportion of eyes with violation of the ISNT rule, laminar dot sign, nasal shifting of the central vessels, nasal excavation and baring of circumlinear vessel was significantly greater in the eyes with pLPC compared to controls (p < 0.01). There were no significant differences regarding the proportions of eyes with peripapillary atrophy between groups (p < 0.09). Finally, disc size was significantly associated with VCDR (r(2) = 0.47, p < 0.01), with an increase of 0.21 in VCDR for each 1 mm(2) in disc area.Conclusion: Compared to normal controls, eyes with pLPC may present a higher proportion of optic nerve head findings frequently observed in glaucomatous eyes. This seems to be explained in part by the larger discs found in these eyes. We believe care should be taken while classifying them as glaucomatous or not based solely on these characteristics.Universidade Federal de São Paulo, Dept Ophthalmol, BR-04021001 São Paulo, BrazilHosp Med Olhos, Glaucoma Unit, BR-06018180 Osasco, SP, BrazilMayo Clin, Dept Ophthalmol, Jacksonville, FL 32224 USAUniversidade Federal de São Paulo, Dept Ophthalmol, BR-04021001 São Paulo, BrazilWeb of Scienc
Mecanismos de fechamento angular sem bloqueio pupilar: análise de prevalência e resultados terapêuticos
Purpose: To assess the prevalence and treatment outcomes of angle-closure mechanisms other than pupillary block in a population of Brazilian patients.Methods: A retrospective chart review was conducted to evaluate patients who had undergone laser peripheral iridotomy (LPI) due to occludable angles at a single institution between July 2009 and April 2012. An occludable angle was defined as an eye in which the posterior trabecular meshwork was not visible for >= 180 degrees on dark-room gonioscopy. Key exclusion criteria were any form of secondary glaucoma and the presence of >90 degrees of peripheral anterior synechiae. Collected data were age, race, gender, angle-closure mechanism (based on indentation goniocopy and ultrasound biomicroscopy), intraocular pressure (IOP), number of antiglaucoma medications and subsequent management during follow-up. If both eyes were eligible, the right eye was arbitrarily selected for analysis.Results: A total of 196 eyes of 196 consecutive patients (mean age 58.3 +/- 11.6 years) who underwent LPI were included. in most of the patients [86% (169 patients; 133 women and 36 men]), LPI sucessfully opened the angle. Mean IOP was reduced from 18.3 +/- 6.4 mmHg to 15.4 +/- 4.5 mmHg after LPI (p<0.01). Among the 27 patients with persistent occludable angles, the most common underlying mechanisms were plateau iris (56%) and lens-induced component (34%). Most of these patients (85%) were treated with argon laser peripheral iridoplasty (ALPI); approximately 90% showed non-occludable angles following the laser procedure (mean IOP reduction of 18.9%), with no significant differences between patients with plateau iris and lens-induced components (p=0.34; mean follow-up of 11.4 +/- 3.6 months).Conclusions: Our findings suggest that, in this population of Brazilian patients, several eyes with angle closure were not completely treated with LPI. in the present large case series involving middle-age patients, plateau iris was the leading cause of persistent angle closure and was effectively treated with ALPI. A detailed eye examination with indentation gonioscopy should always be performed after LPI to rule out persistent angle closure due to non-pupillary block mechanisms.Hosp Med Olhos, Glaucoma Unit, Osasco, SP, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilMayo Clin, Jacksonville, FL 32224 USAUniversidade Federal de São Paulo, São Paulo, BrazilWeb of Scienc
Spiradenocylindrocarcinoma. Report of a case with a low-grade component of spiradenocarcinoma and an immunohistochemical study
Effects of inspired oxygen fractions in rabbits anesthetized with isoflurane or sevoflurane, maintained on spontaneous ventilation
ABSTRACT It is important to identify the best inspired fraction of oxygen in a variety of situations, including sevoflurane or isoflurane anesthesia, in spontaneously breathing rabbits. For this, 64 rabbits were assigned to eight groups: GI100 (FiO2= 1,0 + isoflurane), GS100 (FiO2= 1,0 + sevoflurane), GI80 (FiO2= 0,8 + isoflurane), GS80 (FiO2= 0,8 + sevoflurane), GI60 (FiO2= 0,6 + isoflurane), GS60 (FiO2= 0,6 + sevoflurane), GI21 (FiO2= 0,21 + isoflurane), GS21 (FiO2= 0,21 + sevoflurane). The induction was performed with (2.5MAC) of the anesthetic. The vaporizer was setted at 1.5 MAC and FiO2 as attributed for each group. After the induction, the concentration was changed to 1 MAC. Measurements of parameters were performed 30 minutes after induction (T0), and then at 15 minute intervals (from T15 to T60). The arterial partial pressures of oxygen (PaO2), alveolar oxygen partial pressure (PAO2) and alveolar-arterial oxygen gradient [P(A-a)O2] were higher with the use of high FiO2. The GI80 showed higher levels of PaO2 FiO2 ratio and respiratory index (RI). In conclusion, the FiO2 of 0.21 is not indicated, because it causes hypoxemia. The isoflurane determines better ventilation when compared to sevoflurane, but isoflurane associated with 80% of oxygen promotes intrapulmonary shunt increase.</jats:p
Blood gas analysis in pigs submitted to different concentrations of nitrous oxide or oxygen, under different ventilatory modalities
ABSTRACT The effects of different concentrations of oxygen and nitrous oxide on blood gas parameters in pigs maintained under spontaneous or pressure-controlled ventilation, with or without positive end-expiratory pressure (PEEP), were compared. Forty-eight pigs were randomly divided into six groups, submitted to different concentrations of compressed air or N2O, associated with different fractions of inspired oxygen (FiO2). The group subject to 30% of compressed air (GA30) showed the closest proximity to the physiological range of partial pressure (PaO2) expected for the species. For oxygen saturation (SaO2), the values obtained were below the lower physiological limit in the group administered 30% N2O (GN30). Use of PEEP positively interfered in PaCO2 independent of FiO2, however, its effectiveness can be compromised when complemented by N2O-based anesthesia. For SaO2, only GN30 showed values lower than adequate for maintaining tissue oxygenation. The pH, base deficit and bicarbonate in arterial blood were influenced by FiO2 and N2O. In conclusion, the use of compressed air maintains blood gas parameters at their most stable, especially GA30 and PEEP, which seemed to positively influence the experimental groups, with some interference from FiO2 and N2O.</jats:p
Effects of inspired oxygen fractions in rabbits anesthetized with isoflurane or sevoflurane, maintained on spontaneous ventilation
ABSTRACT It is important to identify the best inspired fraction of oxygen in a variety of situations, including sevoflurane or isoflurane anesthesia, in spontaneously breathing rabbits. For this, 64 rabbits were assigned to eight groups: GI100 (FiO2= 1,0 + isoflurane), GS100 (FiO2= 1,0 + sevoflurane), GI80 (FiO2= 0,8 + isoflurane), GS80 (FiO2= 0,8 + sevoflurane), GI60 (FiO2= 0,6 + isoflurane), GS60 (FiO2= 0,6 + sevoflurane), GI21 (FiO2= 0,21 + isoflurane), GS21 (FiO2= 0,21 + sevoflurane). The induction was performed with (2.5MAC) of the anesthetic. The vaporizer was setted at 1.5 MAC and FiO2 as attributed for each group. After the induction, the concentration was changed to 1 MAC. Measurements of parameters were performed 30 minutes after induction (T0), and then at 15 minute intervals (from T15 to T60). The arterial partial pressures of oxygen (PaO2), alveolar oxygen partial pressure (PAO2) and alveolar-arterial oxygen gradient [P(A-a)O2] were higher with the use of high FiO2. The GI80 showed higher levels of PaO2 FiO2 ratio and respiratory index (RI). In conclusion, the FiO2 of 0.21 is not indicated, because it causes hypoxemia. The isoflurane determines better ventilation when compared to sevoflurane, but isoflurane associated with 80% of oxygen promotes intrapulmonary shunt increase.</div
Blood gas analysis in pigs submitted to different concentrations of nitrous oxide or oxygen, under different ventilatory modalities
ABSTRACT The effects of different concentrations of oxygen and nitrous oxide on blood gas parameters in pigs maintained under spontaneous or pressure-controlled ventilation, with or without positive end-expiratory pressure (PEEP), were compared. Forty-eight pigs were randomly divided into six groups, submitted to different concentrations of compressed air or N2O, associated with different fractions of inspired oxygen (FiO2). The group subject to 30% of compressed air (GA30) showed the closest proximity to the physiological range of partial pressure (PaO2) expected for the species. For oxygen saturation (SaO2), the values obtained were below the lower physiological limit in the group administered 30% N2O (GN30). Use of PEEP positively interfered in PaCO2 independent of FiO2, however, its effectiveness can be compromised when complemented by N2O-based anesthesia. For SaO2, only GN30 showed values lower than adequate for maintaining tissue oxygenation. The pH, base deficit and bicarbonate in arterial blood were influenced by FiO2 and N2O. In conclusion, the use of compressed air maintains blood gas parameters at their most stable, especially GA30 and PEEP, which seemed to positively influence the experimental groups, with some interference from FiO2 and N2O
Association between corneal biomechanical properties and optic nerve head morphology in newly diagnosed glaucoma patients
Background: To investigate the association between corneal biomechanics and optic nerve head morphology in newly diagnosed primary open-angle glaucoma patients. Design: Hospital based prospective study. Participants: Forty-two untreated newly diagnosed primary open-angle glaucoma patients. Methods: Patients underwent corneal hysteresis measurement using the Ocular Response Analyzer and confocal scanning laser ophthalmoscopy for optic nerve head topography evaluation. One eye was selected randomly for analysis. Data collected included age, race, gender, intraocular pressure and central corneal thickness. Main Outcome Measures: Multiple regression analysis (controlling for baseline intraocular pressure and disc area) was used to investigate factors associated with the following optic nerve head topographic parameters: linear cup-to-disc ratio and mean cup depth. Results: Mean age of participants was 66.7 +/- 11.8 years. Corneal hysteresis was the only factor significantly associated with both mean cup depth (correlation coefficient [r] = -0.34, P = 0.03) and cup-to-disc ratio (r = -0.41, P = 0.01). Central corneal thickness was significantly associated with mean cup depth (r = -0.35, P = 0.02), but not with cup-to-disc ratio (r = -0.25, P = 0.13). Although a trend towards a positive association between age and cup-to-disc ratio was identified (r = 0.26, P = 0.08), age was not significantly associated with mean cup depth (r = 0.06, P = 0.72). When comparing fellow eyes of patients with bilateral glaucoma, the eye with higher corneal hysteresis had smaller cup-to-disc ratio in 75% of the cases. Conclusions: in untreated newly diagnosed primary open-angle glaucoma patients, those with thinner corneas and mainly lower corneal hysteresis values had a larger cup-to-disc ratio and deeper cup, independently of intraocular pressure values and disc size.New York Glaucoma Research Institute, New York, NYUniversidade Federal de São Paulo, Dept Ophthalmol, Glaucoma Serv, BR-05466040 São Paulo, BrazilHosp Med Olhos, São Paulo, BrazilNew York Eye & Ear Infirm, Einhorn Clin Res Ctr, New York, NY 10003 USANew York Med Coll, Valhalla, NY 10595 USAUniversidade Federal de São Paulo, Dept Ophthalmol, Glaucoma Serv, BR-05466040 São Paulo, BrazilWeb of Scienc
Blood gas analysis in pigs submitted to different concentrations of nitrous oxide or oxygen, under different ventilatory modalities
ABSTRACT The effects of different concentrations of oxygen and nitrous oxide on blood gas parameters in pigs maintained under spontaneous or pressure-controlled ventilation, with or without positive end-expiratory pressure (PEEP), were compared. Forty-eight pigs were randomly divided into six groups, submitted to different concentrations of compressed air or N2O, associated with different fractions of inspired oxygen (FiO2). The group subject to 30% of compressed air (GA30) showed the closest proximity to the physiological range of partial pressure (PaO2) expected for the species. For oxygen saturation (SaO2), the values obtained were below the lower physiological limit in the group administered 30% N2O (GN30). Use of PEEP positively interfered in PaCO2 independent of FiO2, however, its effectiveness can be compromised when complemented by N2O-based anesthesia. For SaO2, only GN30 showed values lower than adequate for maintaining tissue oxygenation. The pH, base deficit and bicarbonate in arterial blood were influenced by FiO2 and N2O. In conclusion, the use of compressed air maintains blood gas parameters at their most stable, especially GA30 and PEEP, which seemed to positively influence the experimental groups, with some interference from FiO2 and N2O.</div
