8,868 research outputs found

    Glucocorticoids improve acute dizziness symptoms following acute unilateral vestibulopathy.

    Get PDF
    Acute unilateral vestibulopathy (AUV) is characterized by acute vertigo, nausea, and imbalance without neurological deficits or auditory symptomatology. Here, we explore the effect of glucocorticoid treatment on the degree of canal paresis in patients with AUV, and critically, establish its relationship with dizziness symptom recovery. We recruited consecutive patients who were retrospectively assigned to one of the two groups according to whether they received glucocorticoid treatment (n = 32) or not (n = 44). All patients underwent pure-tone audiometry, bithermal caloric testing, MRI brain imaging, and were asked to complete a dizziness handicap inventory on admission to hospital and just prior to hospital discharge. In the treatment group, the canal paresis at discharge was significantly lower than in the control group (mean ± SD % 38.04 ± 21.57 versus 82.79 ± 21.51, p < 0.001). We also observed a significant reduction in the intensity of nystagmus in patients receiving glucocorticoid treatment compared to the non-treatment group (p = 0.03). DHI test score was significantly lower at discharge in the treatment group (mean ± SD % 23.15 ± 12.40 versus 64.07 ± 12.87, p < 0.001), as was the length of hospital stay (2.18 ± 1.5 days versus 3.6 ± 1.7 days, p = 0.002). Glucocorticoid treatment leads to acute symptomatic improvement, with a reduced hospital stay and reduction in the intensity of acute nystagmus. Our findings suggest that glucocorticoids may accelerate vestibular compensation via a restoration of peripheral vestibular function, and therefore has important clinical implications for the treatment of AUV

    New measurement methods for anechoic chamber characterization

    Get PDF
    As a continuation of the work presented in 122nd AES Convention, this paper tries to study in depth the anechoic chambers qualification. The purpose of this paper is to find parameters that allow the characterization of this type of enclosures. The proposal that becomes in this work is trying to obtain data of the anechoic chambers absorption by means of the transfer functions between pairs of microphones, or by means of the impulse response between pairs of microphones. Based on the results of the transfer functions between pairs of microphones can be checked easily agreement of the inverse squared law, allowing to determine the chamber cut-off frequency. Making a band-pass filtering it could be confirmed the anechoic chambers qualification

    Volume modulus inflection point inflation and the gravitino mass problem

    Full text link
    Several models of inflection point inflation with the volume modulus as the inflaton are investigated. Non-perturbative superpotentials containing two gaugino condensation terms or one such term with threshold corrections are considered. It is shown that the gravitino mass may be much smaller than the Hubble scale during inflation if at least one of the non-perturbative terms has a positive exponent. Higher order corrections to the Kahler potential have to be taken into account in such models. Those corrections are used to stabilize the potential in the axion direction in the vicinity of the inflection point. Models with only negative exponents require uplifting and in consequence have the supersymmetry breaking scale higher than the inflation scale. Fine-tuning of parameters and initial conditions is analyzed in some detail for both types of models. It is found that fine-tuning of parameters in models with heavy gravitino is much stronger than in models with light gravitino. It is shown that recently proposed time dependent potentials can provide a solution to the problem of the initial conditions only in models with heavy gravitino. Such potentials can not be used to relax fine tuning of parameters in any model because this would lead to values of the spectral index well outside the experimental bounds.Comment: 27 pages, 9 figures, comments and references added, version to be publishe

    Occurrence of the Oribatid Mite Trhypochthoniellus longisetus longisetus (Acari: Trhypochthoniidae) on Tilapia (Oreochromis niloticus).

    Get PDF
    Mites as parasites infesting fish have been described in a few case reports involving Histiostoma anguillarum, H. papillata, and Schwiebea estradai. We describe the unexpected occurrence of oribatid mites of the genus Trhypochthoniellus on farmed tilapia Oreochromis niloticus. The fish had mites on the skin, fins, and gills, as well as in the mouth. The morphological characteristics of the mites, observed by optical and scanning electron microscopy, were consistent with those described for T. longisetus longisetus. All stages of development were observed, suggesting that the mites were able to actively reproduce on fis

    GRASSP: a spectrograph for the study of transient luminous events

    Get PDF
    We present the main parameters, design features, and optical characterization of the Granada Sprite Spectrograph and Polarimeter (GRASSP), a ground- based spectrographic system intended for the analysis of the spectroscopic signature of transient luminous events (TLEs) occurring in the mesosphere of the Earth. It has been designed to measure the spectra of the light emitted from TLEs with a mean spectral resolution of 0.235 nm and 0.07 nm/px dispersion in the wavelength range between 700 and 800 nm. (C) 2016 Optical Society of AmericaSpanish Ministry of Science and Innovation, Ministerio de Economia y Competitividad (MINECO) (ESP2013-48032-C5-5-R, ESP2015-69909-C5-2-R, FIS2014-61774-EXP); European Union FEDER Program; Ramon y Cajal Contract (RYC-2011-07801).Peer reviewe

    Lab-on-a-chip platforms based on highly sensitive nanophotonic Si biosensors for single nucleotide DNA testing

    Get PDF
    In order to solve the drawbacks of sensitivity and portability in optical biosensors we have developed ultrasensitive and miniaturized photonic silicon sensors able to be integrated in a "lab-on-a-chip" microsystem platform. The sensors are integrated Mach-Zehnder interferometers based on TIR optical waveguides (Si/SiO2/Si3N4) of micro/nanodimensions. We have applied this biosensor for DNA testing and for detection of single nucleotide polymorphisms at BRCA-1 gene, involved in breast cancer development, without target labeling. The oligonucleotide probe is immobilized by covalent attachment to the sensor surface through silanization procedures. The hybridization was performed for different DNA target concentrations showing a lowest detection limit at 10 pM. Additionally, we have detected the hybridization of different concentrations of DNA target with two mismatching bases corresponding to a mutation of the BRCA-1 gene. Following the way of the lab-on-a-chip microsystem, integration with the microfluidics has been achieved by using a novel fabrication method of 3-D embedded microchannels using the polymer SU-8 as structural material. The optofluidic chip shows good performances for biosensing
    corecore