526 research outputs found

    Associations between cardiorespiratory fitness, physical activity and clustered cardiometabolic risk in children and adolescents: the HAPPY study

    Get PDF
    Clustering of cardiometabolic risk factors can occur during childhood and predisposes individuals to cardiometabolic disease. This study calculated clustered cardiometabolic risk in 100 children and adolescents aged 10-14 years (59 girls) and explored differences according to cardiorespiratory fitness (CRF) levels and time spent at different physical activity (PA) intensities. CRF was determined using a maximal cycle ergometer test, and PA was assessed using accelerometry. A cardiometabolic risk score was computed as the sum of the standardised scores for waist circumference, blood pressure, total cholesterol/high-density lipoprotein ratio, triglycerides and glucose. Differences in clustered cardiometabolic risk between fit and unfit participants, according to previously proposed health-related threshold values, and between tertiles for PA subcomponents were assessed using ANCOVA. Clustered risk was significantly lower (p < 0.001) in the fit group (mean 1.21 ± 3.42) compared to the unfit group (mean -0.74 ± 2.22), while no differences existed between tertiles for any subcomponent of PA. Conclusion These findings suggest that CRF may have an important cardioprotective role in children and adolescents and highlights the importance of promoting CRF in youth

    Choice of activity-intensity classification thresholds impacts upon accelerometer-assessed physical activity-health relationships in children

    Get PDF
    It is unknown whether using different published thresholds (PTs) for classifying physical activity (PA) impacts upon activity-health relationships. This study explored whether relationships between PA (sedentary [SED], light PA [LPA], moderate PA [MPA], moderate-to-vigorous PA, vigorous PA [VPA]) and health markers differed in children when classified using three different PTs

    Average acceleration and intensity gradient of primary school children and associations with indicators of health and wellbeing

    Get PDF
    Average acceleration (AvAcc) and intensity gradient (IG) have been proposed as standardised metrics describing physical activity (PA) volume and intensity, respectively. We examined hypothesised between-group PA differences in AvAcc and IG, and their associations with health and wellbeing indicators in children. ActiGraph GT9X wrist accelerometers were worn for 24-h·d−1 over seven days by 145 children aged 9-10. Raw accelerations were averaged per 5-s epoch to represent AvAcc over 24-h. IG represented the relationship between log values for intensity and time. Moderate-to-vigorous PA (MVPA) was estimated using youth cutpoints. BMI z-scores, waist-to-height ratio (WHtR), peak oxygen uptake (VO2peak), Metabolic Syndrome risk (MetS score), and wellbeing were assessed cross-sectionally, and 8-weeks later. Hypothesised between-group differences were consistently observed for IG only (p<.001). AvAcc was strongly correlated with MVPA (r=0.96), while moderate correlations were observed between IG and MVPA (r=0.50) and AvAcc (r=0.54). IG was significantly associated with health indicators, independent of AvAcc (p<.001). AvAcc was associated with wellbeing, independent of IG (p<.05). IG was significantly associated with WHtR (p<.01) and MetS score (p<.05) at 8-weeks follow-up. IG is sensitive as a gauge of PA intensity that is independent of total PA volume, and which relates to important health indicators in children

    The backwards comparability of wrist worn GENEActiv and waist worn ActiGraph accelerometer estimates of sedentary time in children

    Get PDF
    Objectives: To examine the backward comparability of a range of wrist-worn accelerometer estimates of sedentary time (ST) with ActiGraph 100 count∙min-1 waist ST estimates. Design: Cross-sectional, secondary data analysis Method: One hundred and eight 10-11-year-old children (65 girls) wore an ActiGraph GT3X+ accelerometer (AG) on their waist and a GENEActiv accelerometer (GA) on their non-dominant wrist for seven days. GA ST data were classified using a range of thresholds from 23-56 mg. ST estimates were compared to AG ST 100 count∙min-1 data. Agreement between the AG and GA thresholds was examined using Cronbach’s alpha, intraclass correlation coefficients (ICC), limits of agreement (LOA), Kappa values, percent agreement, mean absolute percent error (MAPE) and equivalency analysis. Results: Mean AG total ST was 492.4 minutes over the measurement period. Kappa values ranged from 0.31-0.39. Percent agreement ranged from 68-69.9%. Cronbach’s alpha values ranged from 0.88-0.93. ICCs ranged from 0.59-0.86. LOA were wide for all comparisons. Only the 34 mg threshold produced estimates that were equivalent at the group level to the AG ST 100 count∙min-1 data though sensitivity and specificity values of ~64% and ~74% respectively were observed. Conclusions: Wrist-based estimates of ST generated using the 34 mg threshold are comparable with those derived from the AG waist mounted 100 count∙min-1 threshold at the group level. The 34 mg threshold could be applied to allow group-level comparisons of ST with evidence generated using the ActiGraph 100 count∙min-1 method though it is important to consider the observed sensitivity and specificity results when interpreting findings

    Cut-point-free accelerometer metrics to assess children's physical activity: an example using the school day

    Get PDF
    The aims were to (i) investigate associations between a novel accelerometer metric: the minimum acceleration value above which the most active 30-minutes were accumulated during the school day (M30ACC), and health indicators, and (ii) demonstrate that applying an equivalent cut-point to the M30ACC metric gives comparable prevalence results as a moderate-to-vigorous physical activity (MVPA) cut-point approach. Two-hundred-and-ninety-six children (age 9-10-years) wore wrist-mounted accelerometers for 7-days. School day MVPA and M30ACC were calculated. Body mass index (BMI), waist-to-height ratio (WHtR), and cardiorespiratory fitness (CRF) were also measured. Mixed linear models investigated associations between M30ACC and health indicators. Agreement between ranked MVPA and M30ACC values was assessed using percent agreement, kappa, sensitivity, and specificity statistics. M30ACC thresholds associated with health indicators were 213 mg (BMI), 206 mg (WHtR), and 269 mg (CRF) for girls. The equivalent values for boys were 234mg (BMI), 230 mg (WHtR), and 327 mg (CRF). Less than half of girls and 75% of boys accumulated 30 minutes of school day MVPA. Just less than 50% of girls and >80% of boys had M30ACC values ≥200 mg, which is equivalent to brisk walking. Agreement between MVPA and M30ACC tertiles was high, reflected by the sensitivity and specificity values of > 90%. Results demonstrate the utility of M30ACC as a PA metric that is not heavily influenced by researcher decisions. M30ACC has potential as an accelerometer-specific metric for generating PA guidelines related to health indicators, and easily understood forms of activity such as brisk walking

    Pharmacokinetics and metabolism of ifosfamide in relation to DNA damage assessed by the COMET assay in children with cancer

    Get PDF
    The degree of damage to DNA following ifosfamide (IFO) treatment may be linked to the therapeutic efficacy. The pharmacokinetics and metabolism of IFO were studied in 19 paediatric patients, mostly with rhabdomyosarcoma or Ewings sarcoma. Ifosfamide was dosed either as a continuous infusion or as fractionated doses over 2 or 3 days. Samples of peripheral blood lymphocytes were obtained during and up to 96 h after treatment, and again prior to the next cycle of chemotherapy. DNA damage was measured using the alkaline COMET assay, and quantified as the percentage of highly damaged cells per sample. Samples were also taken for the determination of IFO and metabolites. Pharmacokinetics and metabolism of IFO were comparable with previous studies. Elevations in DNA damage could be determined in all patients after IFO administration. The degree of damage increased to a peak at 72 h, but had returned to pretreatment values prior to the next dose of chemotherapy. There was a good correlation between area under the curve of IFO and the cumulative percentage of cells with DNA damage (r2 = 0.554, P = 0.004), but only in those patients receiving fractionated dosing. The latter patients had more DNA damage (mean ± s.d., 2736 ± 597) than those patients in whom IFO was administered by continuous infusion (1453 ± 730). The COMET assay can be used to quantify DNA damage following IFO therapy. Fractionated dosing causes a greater degree of DNA damage, which may suggest a greater degree of efficacy, with a good correlation between pharmacokinetic and pharmacodynamic data

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Validating the Sedentary Sphere method in children: does wrist or accelerometer brand matter?

    Get PDF
    This study aimed to validate the Sedentary Sphere posture classification method from wrist-worn accelerometers in children. Twenty-seven 9-10-year-old children wore ActiGraph GT9X (AG) and GENEActiv (GA) accelerometers on both wrists, and activPAL on the thigh while completing prescribed activities: five sedentary activities, standing with phone, walking (criterion for all 7: observation) and ten minutes free-living play (criterion: activPAL). In an independent sample, 21 children wore AG and GA accelerometers on the non-dominant wrist and activPAL for two days of free-living. Percent accuracy, pairwise 95% equivalence tests (±10% equivalence zone) and intra-class correlation coefficients (ICC) analyses were completed. Accuracy was similar, for prescribed activities irrespective of brand (non-dominant wrist: 77%-78%; dominant wrist: 79%). Posture estimates were equivalent between wrists within brand (±6%, ICC>0.81, lower 95% CI>0.75), between brands worn on the same wrist (±5%, ICC>0.84, lower 95% CI>0.80) and between brands worn on opposing wrists (±6%, ICC>0.78, lower 95% CI>0.72). Agreement with activPAL during free-living was 77%, but sedentary time was underestimated by 7% (GA) and 10% (AG). The Sedentary Sphere can be used to classify posture from wrist-worn AG and GA accelerometers for group-level estimates in children, but future work is needed to improve the algorithm for better individual-level results

    Search for direct pair production of the top squark in all-hadronic final states in proton-proton collisions at s√=8 TeV with the ATLAS detector

    Get PDF
    The results of a search for direct pair production of the scalar partner to the top quark using an integrated luminosity of 20.1fb−1 of proton–proton collision data at √s = 8 TeV recorded with the ATLAS detector at the LHC are reported. The top squark is assumed to decay via t˜→tχ˜01 or t˜→ bχ˜±1 →bW(∗)χ˜01 , where χ˜01 (χ˜±1 ) denotes the lightest neutralino (chargino) in supersymmetric models. The search targets a fully-hadronic final state in events with four or more jets and large missing transverse momentum. No significant excess over the Standard Model background prediction is observed, and exclusion limits are reported in terms of the top squark and neutralino masses and as a function of the branching fraction of t˜ → tχ˜01 . For a branching fraction of 100%, top squark masses in the range 270–645 GeV are excluded for χ˜01 masses below 30 GeV. For a branching fraction of 50% to either t˜ → tχ˜01 or t˜ → bχ˜±1 , and assuming the χ˜±1 mass to be twice the χ˜01 mass, top squark masses in the range 250–550 GeV are excluded for χ˜01 masses below 60 GeV

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT
    corecore